Metal 

Rod

Brass 

Extension

Brass 

Extension Nut

Nozzle 

Adapter

Nozzle

6-8135

Dripless Shut-off

Cierre antigoteo

Arrêt anti-goutte

6-4608

Pressure Relief Valve

Válvula de descarga de 

presión

Soupape de 

décompression

WARNING

3. Pre-Use Check

 1) 

Do:

 Check tightness of hose nut to be sure hose is securely attached to the tank outlet. 

 2) 

Do:

 Inspect hose for deterioration, cracks, softness, or brittleness. If any of these conditions are 

 

  found, replace hose before using. Replace with original manufacturer’s parts only. 

 3) 

Do:

 Remove pump (see Filling, Pressurizing and Spraying Instructions), inspect interior and 

 

  exterior of tank for signs of deterioration of body and bottom. Any sign of deterioration indicates 

 

  possible tank weakening and could result in explosive bursting under pressure. If any of these 

 

  signs are found, discard tank immediately and replace. Do not attempt to patch leaks, etc., as this 

 

  could result in serious injury. 

 4) 

Do:

 Follow Filling, Pressurizing and Spraying Instructions, except use water only 

 

  (Pump plunger 10-20 strokes and inspect for leaks). 

 5) 

Do:

 Direct shut-off away from you and open to make sure discharge is not clogged. 

 6) 

Do:

 If unit passes this test, release pressure (see Pressure Releasing Instructions), empty tank, 

 

  and proceed with Filling, Pressurizing and Spraying Instructions.

 7) 

Do:

 Inspect all metal parts including the wand, nozzle and fittings for rust, corrosion and pitting. 

 

  If any of these conditions are found, replace affected part with original manufacturer’s part 

 

  before using.

4. Filling

 1) 

Do: 

Turn pump handle counterclockwise and remove pump

 2) 

Do: 

Prepare spray solution following all directions and safety warnings on chemical label.

 3) 

Do: 

Fill tank to no more than the proper gallon marker. Do NOT: over fill to accommodate pump.

 4) 

Do:

 Check pump to make sure that no grass or dirt is stuck to barrel. Replace pump in tank and 

 

  tighten securely.

9. Care, Storage and Maintenance

 1) 

Do: 

Follow chemical manufacture’s instructions for cleaning. Rinse thoroughly with 

 

  recommended solvent. Follow Filling, Pressurizing and Spraying Instructions, except pump unit 

 

  only 8-10 strokes. Be sure that the wand and nozzle are thoroughly rinsed after each use.

 2) 

Do:

 Open shut-off and allow recommended solvent to run through discharge assembly. 

 3) 

Do:

 Release pressure (Follow Pressure Release Instructions), remove pump and empty sprayer. 

 4) 

Do:

 Store sprayer tank upside down, with pump removed, in a warm dry location. 

 5) 

Do:

 Periodically oil pump by dropping 10-12 drops of light oil down pump rod through opening 

 

  in cover.

011534-7 (A) R1020

P.O. Box 549 700 Ellicott St.

Batavia, NY 14021-0549 U.S.A.

1-800-950-4458 www.chapinmfg.com

1. Hose to Tank

Discharge/ Assembly

 

• Make sure white outlet tube is attached to outlet tube adapter (Fig. 1A).
• Insert the outlet tube portion of the discharge assembly into the tank adapter (Fig. 1B).
• Proper placement of white outlet tube (Fig. 1C).
• Firmly insert the outlet tube adapter into the tank adapter (Fig. 1D) Lining up tab with notches on 
  the tank adapter. 
•  Firmly tighten the retaining nut to the tank adapter (Fig. 1E).

Discharge 
Assembly

1B

Outlet 
Tube

1E

Retaining Nut - 

Securely tightened.

1C

1D

No 

Gap

Tank

Adapter

Outlet Tube 

Adapter

Tab/

Notch

1A

Outlet Tube 

Adapter

Outlet 

Tube

Parts, Piezas, Pièces

6-4604

Repair Parts Kit Gaskets and Seals (not included), 

Juego de piezas de reparación, empaquetaduras y juntas (no incluido)

Kit de pièces de réparation, joints et garniture d’étanchéité (non inclus)

Note:

 Your particular sprayer may not include all parts pictured above.

Nota:

 Es posible que este pulverizador en particular no incluya todas las partes que se ilustran arriba.

Remarque :

 Votre pulvérisateur particulier pourrait ne pas inclure toutes les pièces illustrées plus haut.

Congratulations! 

You have just purchased a quality Chapin product. 

Register Your Sprayer Online @ www.chapinmfg.com Questions? Do Not Return To Store. 

Call us @ 1-800-950-4458 or www.chapinmfg.com

6-6093

Hose Black

Manguera para trabajos 

pesados Negro

Tuyau pour service 

intense Noir

6. Lock Off

 

For safety lock-off feature (no-spraying), 

 

push trigger forward and rotate locking 

 

mechanism into lock-off position(Fig. 6A).

6-8136

Valve Seat Kit

Kit de la válvula

Ensemble de soupape

6A

6A

Lock

Trigger

WARNING: Improper use or failure to follow instructions can result in explosive failure causing serious 

eye or other injury.

 For safe use of this product you must read and follow all instructions. Do not leave a 

pressurized sprayer in the hot sun. Heat can cause pressure build-up resulting in possible explosion. Do not 

store or leave solution in tank after use. Always wear goggles, gloves, long sleeve shirt, long pants and full foot 

protection when spraying. Never use any tool to remove pump if there is pressure in sprayer. Never stand with 

face or body over top of tank when pumping or loosening pump to prevent ejecting pump assembly and/or 

solution from striking and injuring you. Never pressurize sprayer by any means other than the original pump. 

Do not attempt to modify this sprayer. Replace parts only with manufacturer’s original parts. 

This sprayer is 

intended for Acetone only. Acetone is extremely flammable. This Acetone sprayer is intended for trained 

professionals only. Not intended for the retail trade. Always read and follow chemical manufacturer’s 

instructions before use with this sprayer as some chemicals may be hazardous when used with this sprayer.

Sk-1169-1

6-1929

Nozzle & Brass Adapter

Tobera

Buse

5. Pressurizing and Spraying

Do: 

Turn handle 

clockwise to tighten. 
Push handle down, 
turn 1/4 turn counter-
clockwise to release.

Do: 

Pump until you 

feel resistance.

Do: 

Push handle, down, turn 1/4 

turn clockwise to lock. Begin 
spraying. Re-pump sprayer as 
required to maintain spray force.

5A

5A

5C

5C

5B

5B

7. To Release Pressure

 

1) Your sprayer is equipped with a pressure 

 

  relief/release valve (Fig. 7A). To release 

 

  pressure lift and hold the cap until air is 

 

  completely exhausted, or, turn the valve slowly 

 

  counter-clockwise until you hear air escaping 

 

  and wait air is completely exhausted (Fig. 7B). 

 2) 

Do:

 Stay away from the sprayer until all air 

 

  has escaped.

7A

7A

8. Wand Dock Clip

7B

7B

Choose the holder that fits your wand.

301630-2

Pump Assembly

Asamblea de la 

bomba

Assemblée de pompe

2. Extension wand and Nozzle Assembly

To attach nozzle directly to shut-off, unthread brass extension nut and metal rod. Assemble 
valve seat (included), nozzle adapter and nozzle to the shut-off as shown in figure 2C. Note 
orientation of valve seat. It will leak if assembled incorrectly.

Metal Rod

Shut-off to wand to nozzle assembly 

Shut-off to nozzle assembly with included valve seat 

2A

Metal Rod

Valve Seat

Nozzle Adapter

Nozzle

2B

2C

The dripless shut-off 

comes assembled as 

shown in figure 2A.

Reviews: