Summary of Contents for PW-II

Page 1: ...2 ...

Page 2: ...S AND FUNCTIONS 6 OPERATIONS 8 1 Simple Weighing Mode 8 2 Weighing with Tare 8 3 Changing Unit of Weight Unit ver only 9 4 HOLD Function Hold ver only 9 5 How to SetAuto Power Off 10 BATTERY MAINTENANCE 11 ERROR MESSAGE 11 SPECIFICATIONS 12 ...

Page 3: ...4 PRECAUTIONS ...

Page 4: ...5 ...

Page 5: ...g performance Your special departments can enjoy this high quality reliable CAS product We believe that your needs will be satisfied and you will have proper reliability This manual will help you with proper operation and care of the PW II Please keep it handy for future reference NAMES AND FUNCTIONS OVERALL VIEW DISPLAY KEYBOARD HOLD Version ...

Page 6: ...are Used to make the weight of commodity stable This weight is average value Used to turn on and off the scale Unit Version Option KEY FUNCTIONS KEYS FUNCTIONS Used to set the zero point Used to input or cancel the weight of tare Used to convert the unit of weight Used to turn on and off the scale ...

Page 7: ...the weight becomes stable the display shows the stable sign on You may need to make it 0 000 by pressing key unless the display indicate 0 000 under the empty platter 1 Simple Weighing Mode Place a commodity on the platter Remove the commodity from the platter 2 Weighing with Tare TARE means the weight of container being used for a commodity TARE key function is to subtract the weight of the conta...

Page 8: ...it ver only Press the key in the simple weighing mode You may select kg lb oz or gram as the unit of weight 4 Hold Function Hold ver only HOLD will be displayed twice The average weight will be displayed The hold function will be automatically stopped after the commodity on the tray is removed or the average weight is blinked 6 times When the weight is unstable press the key ...

Page 9: ...splay shows the AP X0 that you wish to take Refer to TABLE 1 Press the key and then the scale saves what you programmed and shows all the segments counting up 0 to 9 TABLE 1 DISPLAY FUNCTION AP oF This function does not automatically power off AP 10 This function does automatically power off when the scale is not in use for 10 minutes AP 30 This function does automatically power off when the scale...

Page 10: ...e may provide incorrect result on measurement Low Battery status Battery cut off display ERROR MESSAGE Error Message on Display Description Solution Err 0 The Err 0 occurs when scale is not stable Remove unstable facts Err 1 The Err 1 occurs when a current zero point has shifted from the last span calibration Please call your CAS dealer Err 3 The Err 3 is an overload error Please remove the weight...

Page 11: ... Only unit version Keys ZERO TARE HOLD Hold Ver UNIT Unit Ver POWER Functions Hold Hold Ver Unit Conversion Unit Ver Dimensions 239 W x 227 D x 66 H mm 9 4 W x 8 9 D x 2 6 H inch Platter size 222 W x 151 D mm 8 7 W x 5 9 D inch Weight About 1 7kg 3 8lb Power 1 5V x 6 units AA size Battery Operation Time Approx 50hours Manganese battery 250hours Alkaline at 20 C 68 F Operating Temperature 10 C 40 C...

Page 12: ...13 MEMO ...

Page 13: ...14 MEMO ...

Page 14: ...15 ...

Page 15: ...16 ...