Page 1: ...Extraction Motor Instruction Manual Contact Caple on 0117 938 7420 for spare parts or www caple co uk MODELS DDMEXT21 DDMEXT25 DDMEXT28 DDMEXT30 DDMEXT40 ...

Page 2: ...tion Motors Please keep this instruction manual for future reference C O NT ENT S Safety Instructions 3 Environmental Protection 5 Useful Warnings 6 DDMEXT21 DDMEXT25 8 DDMEXT30 11 DDMEXT40 14 DDMEXT28 17 Caple Contact Details 20 ...

Page 3: ...rking together with gas oil or coal burning appliances at the same time The motor of the peripheral exhausting group is powered by the cooker hood placed in the kitchen Before connecting the cooker hood to the mains supply make sure that the voltage indicated in the rating plate corresponds to the mains voltage in the home Before carrying out any sort of maintenance or cleaning operation make sure...

Page 4: ...e A P P R O P R I AT E U S E This appliance is intended to be used in household and similar applications such as Staff kitchen areas in shops offices and other working environments Farm Houses By clients in hotels motels and other residential type environments Bed and breakfast type environments ...

Page 5: ...household waste disposal service or the retailer where you purchased the product CE DECLARATIONS OF CONFORMITY This appliance has been manufactured to the strictest standards and complies with all applicable legislation Low Voltage Directive LVD and Electromagnetic Compatibility EMC UKCA DECLARATIONS OF CONFORMITY This appliance has been manufactured to the strictest standards and complies with al...

Page 6: ...warnings included in the instruction manual DDMEXT25 40 are equipped with a 200mm diameter hole for the exhausting pipe If the unit that has to be connected to the remote fan already equipped with a 200mm diameter hole then it is recommended to use a pipe with the same diameter in order to get good performance Otherwise if the unit is equipped with a 150mm diameter hole then it is recommended to u...

Page 7: ...is combined with other products such as ceiling hoods wall hoods and island hoods Once the above mentioned times elapse the motor will switch to 3rd speed automatically DDMEXT40 and DDMEXT25 products have a maximum air capacity higher than 650m3 h at both 4th and 3rd speed therefore they will have the following by default timer control functions DDMEXT40 DDMEXT25 with DOWNDRAFT EM 4th speed is tim...

Page 8: ...DDMEXT21 DDMEXT25 O N S 255mm 302mm 302mm 150mm D I M E N S I O N S 200mm 50mm 350mm 350mm 400mm 150mm 200mm and cted he or y on MEXT25 FIG 1 A A A B These products are designed to efficiently exhaust fumes and odours They must be installed inside the house and connected to the cooker hood which is in the kitchen Fig 1 ...

Page 9: ...t previously chosen for the installation and mark the points on the wall where the holes must be drilled Insert the dowels supplied in the holes Fig 4A Put the extraction motor on the wall by matching the holes of the brackets with the plastic dowels Screw with the screws supplied Fig 4B INSTALLING THE APPLIANCE After deciding the position and the type of installation insert the anti vibration rub...

Page 10: ...ckets Fix with the screws supplied Fig 5B Put the group on the point previously chosen for the installation and mark the points on the wall where the holes must be drilled Insert the dowels supplied in the holes Fig 4A Put the remote fitted extraction motor on the wall by matching the holes of the brackets with the plastic dowels Screw with the screws supplied Fig 4B A B C CONNECTING THE DUCTING T...

Page 11: ...EX T 30 This product is designed to efficiently exhaust fumes and odours It must be installed on the outside wall of the house and connected to the cooker hood in the kitchen Fig 8 use Using on it water sert pply FIG 8 NOTE The Motor must be installed a minimum of 50cm from the floor to avoid back pressures from the extracted air ...

Page 12: ...e to be drilled with an 8mm bit Insert step by step the following parts in the holes drilled The corresponding plastic dowels supplied Fig 9A Two ducting channels not supplied in the hole of 160mm Plastic ducting of 40mm diameter not supplied Before leaning the appliance against the wall insert the supply cord in the plastic ducting Fix the appliance without the stainless steel external body which...

Page 13: ...upplied by the installer ELECTRICAL CONNECTION TO THE HOOD Connect the external motor s cable to the terminal board found inside the plastic box of the wiring Make sure to respect the colours of cables when performing the electrical connection Fig 11 In order to avoid water ingress apply silicone to the product perimeter close to the wall INSTALLING THE STAINLESS STEEL EXTERNAL BODY Refit the stai...

Page 14: ...mm 150 200mm 240mm 195mm 500mm 255mm mm 5 FIG 13 ing ed on e nsert This product is designed to efficiently exhaust fumes and odours It must be installed on the outside wall of the house and connected to the cooker hood in the kitchen Fig 13 NOTE The Motor must be installed a minimum of 50cm from the floor to avoid back pressures from the extracted air ...

Page 15: ...holes on the wall Tighten with the screws supplied The corresponding plastic dowels supplied Fig 14 Two ducting channels not supplied in the hole of 200mm Plastic pipe of 40mm diameter not supplied Before leaning the appliance against the wall remove the stainless steel cover using the 8 perimetrical screws Fig 15 then insert the supply cord in the plastic ducting Fix the appliance without the sta...

Page 16: ...plied by the installer ELECTRICAL CONNECTION TO THE HOOD Connect the external motor s cable to the terminal board found inside the plastic box of the wiring Make sure to respect the colours of cables when performing the electrical connection Fig 17 In order to avoid water ingress apply silicone to the product perimeter close to the wall INSTALLING THE STAINLESS STEEL EXTERNAL BODY Refit the stainl...

Page 17: ... air outlet This product can work only if it is used in combination with a Caple downdraft This product is designed to efficiently exhaust fumes and odours We recommend you use the product in Recirculation Mode only and to use a constant diameter piping of 150mm or similar sections We also recommend using ducting without elbows as they negatively affect the performance of the appliance N S I O N S...

Page 18: ...ing to be connected from the DDMEXT28 to an air outlet grille vent is not supplied with the appliance and should be purchased separately DDMEXT It is possible to direct the product air outlet according to your installation requirements by rotating the air outlet flange as shown in Fig 20 The appliance is equipped with a 7 meter long power cable to be connected to the downdraft hood in the specific...

Page 19: ...NOTES ...

Page 20: ...Caple Service Fourth Way Avonmouth Bristol BS11 8DW T 0117 938 1900 E service caple co uk www caple co uk ...