INSTALLATION MANUAL 

June 2014 

Summary of Contents for Zodiac FR100

Page 1: ...Zodiac FR100TM INSTALLATION MANUAL June 2014...

Page 2: ...5 READER LAYOUT 6 READER INSTALLATION 7 Mounting Plate 9 Reader Mounting 10 READER WIRING 11 Wiegand Reader SmartLock Pro Controller 11 Wiegand Reader H1000 Controller 12 Wiegand Reader 3rd Party Acce...

Page 3: ...f less than 1 second sending the user s Wiegand data to any access control panel to provide accurate user validation Alternatively using its internal relay in stand alone mode it can be used to restri...

Page 4: ...g Distance 30 80cm Working Temperature 0o C 40o C 32o F 104o F Working Humidity 20 80 Installation Method Wall Mount Capture Distance 30 cm 80 cm 11 8 31 5 Communications Cable multi reader configurat...

Page 5: ...r cable to the terminal strip on the control panel Use Splices for Parallel Wiring The terminal strips are designed to allow one cable per hole If you need to connect multiple cables in a single hole...

Page 6: ...ort 13 Mounting plate screw 14 Reset button 15 RJ 45 jack 16 12VDC input jack 17 Terminal blocks 18 SD card slot 19 Mounting plate 20 Speaker 21 Tamper switch Terminal Block Pin 6 10 Pin 6 7 are inter...

Page 7: ...in a place subject to direct sunlight humidity and dust Do not install the reader close to a magnet CRT TV monitor or speaker They may damage the reader Do not to let liquid like water drinks or chemi...

Page 8: ...tion height is 1 2m 47 to read individuals from 155cm to 193cm 5 1 to 6 4 at a distance of 46cm to 91cm 18 to 36 Adjust installation height accordingly for lower or higher height requirements Must be...

Page 9: ...Zodiac FR100TM Page 9 of 15 Installation Manual June 2014 Rev 1 2 MOUNTING PLATE Drill four holes in the wall using mounting bracket as a template Mounting Studs...

Page 10: ...transformer and plug the connector to the 12VDC port through the gap of the mounting plate 5 Install the mounting plate to the wall 1 15 to 1 20 m above the ground See mounting plate section above for...

Page 11: ...tion NOTE The SmartLock controller supports Cansec s 37 bit format as well as standard 26 bit and HID 35 bit Corporate 1000 formats Power from controller to reader Wiegand cables D0 D1 Do not use supp...

Page 12: ...tion NOTE The H1000 controller supports Cansec s 37 bit format as well as standard 26 bit format and HID 35 bit Corporate 1000 format Wiegand cables D0 D1 Power from controller to reader Do not use su...

Page 13: ...controller Only use supplied transformer in standalone application NOTE The Zodiac FR100 reader supports Cansec s 37 bit format as well as standard 26 bit format NOTE The Zodiac FR100 reader requires...

Page 14: ...es diode as shown to prevent back EMF from damaging the reader 2 Ensure that the lock power is 12VDC Maximum 30VDC with sufficient current to power the lock Maximum 1A See lock specifications from man...

Page 15: ...reader 2 Ensure that the lock power is 12VDC with sufficient current to power both the lock and the reader The reader requires 12VDC 500 mA See lock specifications from manufacturer Power source for...