background image

Corrosion 

Control 

Equipment 

and 

Supplies 

 

Distributed by:

!

Houston Office: 

248 McCarty Dr. 

Houston, TX 77029-1195 

(713) 672-8251 

Fax (713) 672-6636 

Dallas Branch: 

4770 Gretna 

Dallas, TX 75207 

(214) 631-0584 

Fax (214) 631-5824 

1-800-BLAST 97 

 

Corpus Christi Branch: 

4750 Westway 

Corpus Chrisi, TX 78408 

(361) 882-8282 

Fax (361) 882-6029 

1-800-CLEMTEX 

www.clemtex.com 

[email protected] 

Summary of Contents for 95A

Page 1: ...ty Dr Houston TX 77029 1195 713 672 8251 Fax 713 672 6636 Dallas Branch 4770 Gretna Dallas TX 75207 214 631 0584 Fax 214 631 5824 1 800 BLAST 97 Corpus Christi Branch 4750 Westway Corpus Chrisi TX 78408 361 882 8282 Fax 361 882 6029 1 800 CLEMTEX www clemtex com clemtex clemtex com ...

Page 2: ...d abrasive coating applications It is also pneumatically activated for application with reciprocating rotary spindle machines and in stationary gun set ups Exceptionally rugged in construction the Binks Model 95A and 95AV guns are built to stand up under hard continuous use However like any other fine precision instrument their most efficient operation depends on a knowledge of their construction ...

Page 3: ...luid may develop a static charge that must be dissipated through proper grounding of the equipment objects to be sprayed and all other electrically conductive objects in the dispensing area Improper grounding or sparks can cause a hazardous condition and result in fire explosion or electric shock and other serious injury FIRE AND EXPLOSION HAZARD Never use 1 1 1 trichloroethane methylene chloride ...

Page 4: ...screw Side Port Control Assembly Fan Pattern Control Fluid Needle Stroke Adjustment Cylinder Air Inlet 1 4 NPS Atomizing Air Inlet 1 4 NPS Mounting Hole 1 2 Dia Fluid Inlet 3 8 NPS Oil and Water Extractor Regulated Cylinder Air From Oil and Water Extractor Regulated Fluid Inlet Four Gun Material Manifold 3 Way Solenoid Four Gun Air Manifold Combined Fan and Atomizing Air 95A or 95AV Automatic Gun ...

Page 5: ...ve 4 Gun Air Mani fold Fan Air For some applications each gun may require individually regulated fluid and air inlet lines GENERAL NOTES 1 Have at least 55 60 P S I air pressure for cylinder s operating air Maximum 90 PSIG 2 To reduce overspray and obtain maximum efficiency always spray with lowest possible fluid air pressure that produces an acceptable spray pattern 3 The air line from gun to 3 w...

Page 6: ...7 material needle 22 and end cap 28 See assembly drawing page 10 7 Remove plug 43 from the fan air port C 8 Install fitting 32 into port C Fitting is packaged loose Plug 43 Remove and install D M Nipple 32 Fan Air Inlet Optional Cylinder Air Inlet Atomizing Air Inlet Fluid Inlet A C 28 B B View A Plug 16 Set Screw 46 Side Cut Away View A WARNING Use of excessive pressure will cause piston to exit ...

Page 7: ... If necessary fluid flow can also be adjusted by adjusting the amount of needle travel This is done by loosening lock nut 29 and adjusting control knob 30 until the correct needle travel is achieved ADJUSTING AIR AND FLUID TIMING A 1 16 gap between the air piston assembly 18 and needle body 24 should be maintained see figure 1 This will create needle motion that will allow adequate air flow before...

Page 8: ...f VOCs into the atmosphere 2 Place spray gun in a washer type container This sys tem must totally enclose the spray gun cups nozzles and other parts during washing rinsing and draining cycles This type of unit must be able to flush solvent through the gun without releasing any VOC vapors into the atmosphere Additionally open containers for storage or disposal of solvent or solvent containing cloth...

Page 9: ... 200 PI 3 1 5 2 6 4 12 0 763A 63BSS x 63PB PE 9 0 14 3 20 0 14 0 763A 63CSS x 63PE PE 9 5 15 0 20 0 13 0 763A 63CSS x 63PR PE 9 5 15 5 19 5 18 0 763A 65SS x 63PR PE 11 0 16 5 22 0 15 0 765 66SS x 66SD SE 7 9 12 1 11 0 765 66SS x 66SK SE 11 0 15 2 19 5 13 0 765 63CSS x 200 PI 3 1 5 2 6 4 12 0 763A 67SS x 206 PI 6 0 9 5 13 0 15 0 767 68SS x 201 PI 4 6 6 8 9 1 11 0 768 68SS x 101 PI 4 6 6 8 9 1 11 0 ...

Page 10: ... 9 95A GUN 66SS 66SD 6469 4308 8 95A GUN 66SS 66SK 6469 5111 5 95A GUN 68SS 68PB 6469 8219 1 95A GUN 59CSS 262 NOTE See pgs 11 13 for 95A fluid nozzles air nozzles and needle ordering information 95AV set ups appear below 95AV GUN 6487 3206 3 95AV GUN 63CVT 66PH 6487 3603 5 95AV GUN 64VT 64PA 6487 4909 5 95AV GUN 67VT 67PB 6487 4909 9 95AV GUN 67VT 67PD 6487 5211 5 95AV GUN 68VT 68PB 95AV NOZZLE S...

Page 11: ...ntrol See pg 4 Items 31 32 and 46 are packaged loose Item 42 must be compressed and inserted inside Item 41 for proper seal function Accessory item Order separately 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 46 44 45 47 18 17 19 20 21 27 26 56 25 24 23 35 36 34 40 54 53 42 52 41 43 32 33 48 49 38 39 28 29 37 22 11 32 31 30 50 51 95AV FLUID INLET 55 55 55 REFERENCE KIT 54 4511 ...

Page 12: ...13 DOUBLE MALE NIPPLE 1 4 NPT x 1 4 NPS 1 41 54 3716 AIR VALVE GLAND ASSEMBLY 1 42 20 3859 O RING 1 43 54 3986 PLUG 1 8 27 NPT 1 44 54 4213 WRENCH Optional 1 45 82 469 GUN BRUSH 1 46 20 2141 SET SCREW 1 4 20 UNC 1 47 54 3871 GUNNERS MATE 1 48 54 4568 FLUID INLET 95AV Gun 1 49 20 2227 O RING 95AV Gun 1 50 54 4531 SPACER 95AV Gun 1 51 54 4542 NUT ASSEMBLY 95AV Gun 1 52 54 3592 FLUID INLET SEAL 1 53 ...

Page 13: ...ith 95A automatic spray gun Package of 20 covers ACCESSORIES Optional Approximate Weight 1 2 lbs 1 2 Dia Gun Mounting 1 Diameter 7 2 4 2 4 1 2 Diameter Hole for Gun Mate Bracket Gun Cover 95A NOZZLE SET UPS STAINLESS STAINLESS STAINLESS STAINLESS STEEL FLUID STEEL FLUID STEEL FLUID STEEL FLUID NOZZLE NOZZLE PART NEEDLE NEEDLE PART COMPATIBLE AIR CAP DESIGNATION NUMBER DESIGNATION NUMBER AIR CAPS P...

Page 14: ... 6041 66S 46 6018 66SD 46 6020 66SD 3 46 6092 66SK 46 6082 67SS 45 6701 767 47 766 67PB 46 6101 67PD 46 6028 706 46 2013 Tip and 54 372 Base 709SS 46 2020 Tip and 54 372 Base 713 46 2025 Tip and 54 372 Base 797 46 156 Tip and 54 372 Base 68SS 45 6801 768 47 768 68PB 46 6032 201 46 2206 Tip and 54 1583 Base 54 1584 Ring 206 46 2206 Tip and 54 1583 Base 54 1584 Ring 706 46 2013 Tip and 54 1583 Base ...

Page 15: ...14 NOTES ...

Page 16: ...15 NOTES ...

Page 17: ...ee listing below U S Canada Technical Service Office 195 Internationale Blvd Glendale Heights IL 60139 Toll Free Telephone 1 888 992 4657 U S A and Canada only Toll Free Fax 1 888 246 5732 Binks Worldwide Sales and Service Listing www binks com WARRANTY This product is covered by Binks 1 Year Limited Warranty 77 2641R 8 Revisions P1 Corrected text P9 Updated Standard part Number chart P11 Updated ...

Reviews: