background image

 

 

 

126305 Rev B 05/22/15

 

 

For new books, FAX to:

 

BENNETT MARKETING SERVICES

 

(231)799

-

6202

 

Or visit our web page at:

 

http://www.bennettpump.com

 

Site Master SP 

Product Manual

 

Bennett 1218 E. Pontaluna Road Spring Lake, MI 49456

 

USA 800

-

235

-

7618 Outside USA 231

-

798

-

1310 [email protected]

 

www.bennettpump.com

 

 

READ THIS BOOK

 

This book has important information for safe installation 
and operation of this equipment.  Read and understand 
this  book  before  applying  power.    Keep  this  book  and 
tell  all  service  personnel  to  read  this  book.    If  these 
instructions  are  not  followed,  bodily  injury,  death,  or 
damage to the equipment may occur.

 

Summary of Contents for Site Master SP

Page 1: ...49456 USA 800 235 7618 Outside USA 231 798 1310 sales bennettpump com www bennettpump com READ THIS BOOK This book has important information for safe installation and operation of this equipment Read...

Page 2: ...ttery 18 Diagnostics 18 Manager s Mode 02 Real Time Clock 18 Manager s Mode 03 Audit Trail Report 19 Manager s Mode 04 Card Reader Diagnostics 21 Manager s Mode 05 Printer Diagnostics 22 Manager s Mod...

Page 3: ...ore working on the equipment WARNING To prevent electric shock keep the electrical parts of the terminal dry WARNING You must have training in the installation service or maintenance of this equipment...

Page 4: ...ease Pay Inside message NOTE Please Pay Inside will be displayed only if the module and or POS Point of Sale has not been configured or installed at this time see figure 1 2 The message will return if...

Page 5: ...he 12vdc voltage source Card Reader Display Backlight Receipt Printer Data The following components use the 24vdc voltage source Receipt Printer Power Display Connector Descriptions All peripherals ar...

Page 6: ...itting with conductor seals Field connections are done in the Upper Electrical Enclosure Wire must extend 60 inches above base of the unit to make Electrical Connections All conductors are to be stran...

Page 7: ...7 126305 Rev B 05 22 15 Installation continued FIGURE 2 3 Field Wiring Diagram Power FIGURE 2 4 Field Wiring Diagram Communication...

Page 8: ...The module has a Manager s Mode used to access programming and diagnostics The following instructions explain how to gain access to the Manager s Mode and how to configure it for operation Using the K...

Page 9: ...ode press the numeric 1 key and press the function Enter key The function Enter key will be used to enter each mode for programming or diagnostics Once the function Enter key is pressed the display wi...

Page 10: ...a number larger than the current count number To shorten the receipt enter a number that is lower than the current number As the new count is entered the display will show the new value see figure 3...

Page 11: ...believe that the receipt is complete and they will begin to remove the paper from the printer chute before it is complete To prevent this from happening Mode 14 is used to send the receipt data to the...

Page 12: ...d 3 18 If programming is complete press the right Soft Key next to EXIT on the display again and the module will return to nor mal operation Manager s Mode 99 There are thirty six different logos that...

Page 13: ...s Mode 99 If programming is complete press the right Soft Key next to EXIT on the display again and the module will return to normal operation 00 No Logo 01 76 Logo 02 Air Products Logo 03 Arco Logo 0...

Page 14: ...gramming Header For Bennett use only J4 Audio Transducer Used to connect the speaker that is used to beep and prompt the user to respond to the module NOTE The 12v on Pins 1 and 2 is the same 12v that...

Page 15: ...he CPU Board using the 12v supplied on Pins 1 and 2 of J5 J8 COM 1 Receipt Printer This is dedicated to RS 232 used to interface the receipt printer J9 COM 2 Auxiliary Connector Natural Gas Com Hub Bo...

Page 16: ...v on Pins 1 and 2 is the same 24v from Pins 3 and 4 of J5 NOTE The same 12v on Pin 3 is the same 12v from Pins 1 and 2 of J5 NOTE The 5v is regulated on the CPU Board using the 12v supplied on Pins 1...

Page 17: ...inks at the rate of 1x per second when in normal run mode D7 Red RS 485 RXD D8 Green RS 485 TXD D11 Red COM 1 Magnetic Card Reader TXD D13 Green COM 1 Magnetic Card Reader RXD D15 Red COM 3 Printer TX...

Page 18: ...nostics There are ten diagnostic modes available with the module These modes are used to help troubleshoot the software keypad printer card reader or encryption Here is a list of diagnostic modes Mode...

Page 19: ...rint the date and time that each event happens These reports will tell when each of the Audit Events have taken place Once the module is in Manager s Mode press the numeric 3 key and press the functio...

Page 20: ...port only reflects the last 25 times that the software reset Notice that the event column left side of report reflects only the software starts event Figure 4 7 is an example of the Clock Change Repor...

Page 21: ...s Mode 04 After the module detects the card reader insert a card to verify that it is working properly When the card is slid into the reader make sure that it has been inserted completely At this poi...

Page 22: ...he keys on the module only This mode does not test any other keys on the terminal After entering into Manager s Mode press the numeric 6 key and press the function Enter key After pressing the functio...

Page 23: ...o exit Manager s Mode 08 If programming is complete press the right Soft Key next to EXIT on the display again and the module will return to normal operation Manager s Mode 09 This mode is used to res...

Page 24: ...umber of messages started Every time a character causes the start of a new message the FE Counter is incremented see figure 4 18 Valid shows the total number of valid messages received and validated s...

Page 25: ...25 126305 Rev B 05 22 15 Parts FIGURE 5 1 5x8 Credit Parts Breakdown 1 2 3 4 6 8 9 10 7 14 11 13 5 12 15 16 17...

Page 26: ...rcuit Board Assembly Side Soft Key 2 6 117416 Bracket Lens Display 1 7 117417 Display Board 1 8 117410 Bracket Display 1 9 117432 Color APM CPU Board 1 10 113558 5x8 Pin Pad Gasket 1 11 113559 5x8 Pin...

Page 27: ...nesses 2 3 4 5 5 1 Item 2 Card Reader Item 4b Printer Power Adaptor Item 5 Soft Key Item 1 Comm Power Item 3 Printer Comm Item 4a Printer Power Harness Item 6 Display Cable 6 Item 7 Alpha Numeric and...

Page 28: ...3 113533 Printer Data Cable comes with Printer Kit 1 4a 115407 Printer Power Harness comes with Printer Kit 1 4b 114586 Printer Power Adaptor 1 5 118553 Soft Key Harness 2 6 117827 Display Cable FCC...

Page 29: ...p Company The above warranties shall not exist if the original identification marks have been removed or altered 2 Bennett makes no warranty with respect to the Bennett equipment or Bennett s performa...

Page 30: ...30 126305 Rev B 05 22 15 Bennett 1218 E Pontaluna Road Spring Lake MI 49456 USA 800 235 7618 Outside USA 231 798 1310 sales bennettpump com www bennettpump com...

Reviews: