Model: M17

en

Assembly and Operating Instructions

Roller shutter drives with mechanical limit switching

Important information for:

• Fitters / • Electricians / • Users

Please forward accordingly!

These instructions must be kept safe for future reference.

Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

2010 300 725 0a     23/05/2022    

Summary of Contents for M17

Page 1: ... mechanical limit switching Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 300 725 0a 23 05 2022 ...

Page 2: ...uctions for installation and commissioning 4 Intended use 6 Assembly 6 Setting the limit positions 8 Blockage detection when moving UP 8 Information for the electrician 9 Disposal 9 Maintenance 9 Technical data dia 45 9 What to do if 10 Sample wiring diagrams 10 Declaration of conformity 12 2 en ...

Page 3: ...avoided could result in injury ATTENTION ATTENTION indicates measures that must be taken to avoid damage to property Denotes user tips and other useful information Warranty Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in serious injuries e g crushing of limbs Therefore structural modifications may only be carried o...

Page 4: ...y the drive manufacturer If any questions or uncertainties regarding the safety instructions contained in the standard arise please contact the manufacturer of the part or end product in question All applicable standards and regulations for electrical installation must be complied with All work including maintenance and cleaning on electrical installations as well as other system parts must always...

Page 5: ... down all lines and control devices that are not essential for op eration Crushing or shearing points must be avoided or protected When installing the drive all pole disconnection from the mains with a contact gap of at least 3 mm per pole must be provided EN 60335 If the mains connecting cable is damaged it may only be replaced by the manufacturer If the drive has a plug in connecting cable it mu...

Page 6: ... Assembly Assembling the drive Attention To connect the drive to the driven part solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used Prior to mounting the fitter must ensure that the masonry and the system being motorised are sufficiently robust drive torque plus weight of the shading solution Caution Electrical connections may only ...

Page 7: ...oove recesses have different sizes and allow the drive to fit exactly Y X For round shafts Measure the lug of the thrust ring X Y Then notch the tube on the motor side so the lug of the thrust ring can also be pushed into the shaft There must be no play between the lug of the thrust ring and the shaft 10 mm To ensure secure torque transmission for round shafts we recommend screwing the drive adapt...

Page 8: ...ntinuous operation and has only been designed for start up Lay the connecting cable Lay the connecting cable up to the tubular drive and fix The connecting cable and any antennae must not project into the winding chamber Cover any sharp edges Setting the limit positions A fixed stop at the upper limit position and fixed shaft connectors must be in place During commissioning and subsequent use ensu...

Page 9: ...ust not execute simultaneous UP and DOWN com mands Protect the electrical connections from damp Once you have finished wiring everything to the control ALWAYS check the right direction assignment of the drive to the control buttons UP and DOWN EXTEND and RETRACT If the drive is to be operated with devices which contain sources of interference the elec trician must ensure suitable interference supp...

Page 10: ...lar drive does not run in the right direction Check the electrical connection Tubular drive does not switch off properly at the lower limit pos ition Use fixed shaft connectors Tubular drive does not switch off properly at the upper limit po sition Fit a fixed stop Sample wiring diagrams The assignment of the black and brown wires according to the direction of travel is de pendent on how the drive...

Page 11: ...ual control using Centronic UnitControl UC42 Mains 230 V 50 Hz Central Group Individual Individual 230 V 50 Hz Central cable connection to further control units 230 V 50 Hz 230 V 50 Hz Electronics 230 V 50 Hz Control unit 11 en ...

Page 12: ...Declaration of conformity 12 en ...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...