Страница 1: ...BandLuxeTM M250 Series HSUPA Module User Manual ...

Страница 2: ......

Страница 3: ... ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED AS IS WITH ALL FAULTS PRODUCT AND THE ABOVE NAMED SUPPLIERS DISCLAIM ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING USAGE OR TRADE PRACTICE IN NO EVENT SHALL PRODUCT OR ITS SUPPLIERS BE LIABLE FOR ANY IN...

Страница 4: ...Table of Contents Section 1 Introduction 1 2 Section 2 Device Driver Interface 2 2 Section 3 AT Command Set Reference 3 2 Section 4 Packing Information 3 2 Section 5 FCC Statement 5 1 ...

Страница 5: ...Description The M250 module series is PCI Express Mini Card providing WWAN HSUPA HSDPA WCDMA EGPRS and GPS connectivity to laptops or any other device equipped with a PCI Express Mini Card slot Figure 1 1 Top View Figure 1 2 Bottom View ...

Страница 6: ...ility that is enabled by using both satellite and network information y The GPS RF path is shared with the UMTS Receive Diversity RF path When the GPS functionality is enabled the UMTS Receive Diversity will be disabled 1 2 4 Baseband Functionality The M250 module interfaces with host device through PCI Express Mini Card interface The interface equips with USB2 0 interface USIM interface LED contr...

Страница 7: ...0V only 12 UIM_CLK 13 PCM_CLK M250V only 14 UIM_RESET 15 GND 16 N C 17 N C 18 GND 19 N C 20 W_DISABLE 21 GND 22 HW_RST 23 N C GPIO3 optional 24 Vaux 25 N C 26 GND 27 GND 28 N C 29 GND 30 N C 31 N C 32 N C 33 N C 34 GND 35 GND 36 USB_D 37 GND 38 USB_D 39 Vaux 40 GND 41 Vaux 42 LED_WWAN 43 GND 44 N C 45 N C 46 N C 47 N C 48 N C 49 N C 50 GND 51 N C 52 Vaux For more information please refer to PCI SI...

Страница 8: ... Table 2 3 describes the LED output characteristics in different states Figure 1 4 LED Current Driver Example Current Control M250 Module VDD PIN42 Table 1 2 LED Output LED State Module Status Description LED Characteristics OFF Module is not powered LED is OFF ON Module is powered and camped on network but not transmitting or receiving LED is continuously ON Slow blink Module is powered and searc...

Страница 9: ...tate Module Status Description LED Characteristics Intermittent blink Module is transmitting or receiving LED is flashing intermittently during data transfer activity 50ms 5 ON period and 250ms 5 OFF period ...

Страница 10: ...SIM provides the required subscription information to allow the mobile equipment to attach to a GSM or UMTS network The USIM also provides the subscriber s verification procedures as well as authentication methods for network authentication during the network registration procedures Upon power up or after a soft reset the clock and data lines to the USIM will be active through the initialization p...

Страница 11: ... of multi band antenna required for the M250 module series 1 6 1 Antenna specifications Frequency range y GSM850 824 894 MHz y EGSM900 880 960 MHz y DCS1800 1710 1880 MHz y PCS1900 1850 1990 MHz y WCDMA 850 1900 2100 824 894 1850 1990 1920 2170 MHz y GPS 1575 42MHz 1 023MHz Maximum permitted peak gain 5 8dBi at 850MHz and 0 31dBi at 1850MHz Maximum VSWR y 2 5 1 with 50 reference impedance Polariza...

Страница 12: ...stics interface All device drivers used by OS have been created for Microsoft Windows Vista 32 64 Windows XP SP2 above Windows 2000 SP4 above Mac OSX 10 4 above and Linux Fedora 8 Unbuntu 7 Open SuSE 10 Either the modem or the NDIS interface can be used to transfer data and AT command interface or diagnostic interface could be used to send receive information of the module via the Connection Manag...

Страница 13: ...ation mode ATQ value ATV Set result code format mode ATV value ATZ Set all current parameters to user defined profile ATZ mode ATS3 Write command line termination character S3 n S3 S3 ATS4 Set response formatting character S4 n S4 S4 ATS5 Write command line editing character S5 n S5 S5 AT GMI Request manufacturer identification AT GMI AT GMM Request model identification AT GMM AT GMR Request revis...

Страница 14: ...p AT CGDSCONT AT CGDSCONT AT CGTFT Traffic Flow Template AT CGTFT cid packet filter identifier evaluation precedence index source address and subnet mask protocol number ipv4 next header ipv6 destination port range source port range ipsec security parameter index spi type of service tos ipv4 and mask traffic class ipv6 and mask flow label ipv6 AT CGTFT AT CGTFT AT CGEQREQ 3G Quality of Service Pro...

Страница 15: ...ean AT CGQREQ AT CGQREQ AT CGQMIN Quality of Service Profile Minimum acceptable AT CGQMIN cid precedence delay reliability peak mean AT CGQMIN AT CGQMIN AT CGEREP Subscriber number AT CGEREP mode bfr AT CGEREP AT CGEREP AT CGPADDR Show PDP address AT CGPADDR cid cid AT CGPADDR AT CGCLASS GPRS mobile station class AT CGCLASS class AT CGCLASS AT CGCLASS AT CGSMS Select service for MO SMS messages AT...

Страница 16: ...ex1 index2 AT CPBR AT CPBF Find Phonebook Memory entries AT CPBF findtext AT CPBF AT CPBW Write phone book entry AT CPBW index number type text AT CPBW AT CPMS Preferred Message Storage AT CPMS mem1 mem2 mem3 AT CPMS AT CPMS AT CNMI New Message Indications to TE AT CNMI mode mt bm ds bfr AT CNMI AT CNMI AT CMGL List Messages AT CMGL stat AT CMGL AT CMGR Read Message AT CMGR index AT CMGR AT CMGS S...

Страница 17: ...entification AT CGMR AT CGSN Request product serial number identification AT CGSN AT CNUM Subscriber number AT CNUM AT CNUM AT CSIM Generic SIM access COLP n AT CRSM Restricted SIM access AT CRSM command fileid P1 P2 P3 data AT CRSM AT COPN Read operator names AT COPN AT COPN AT CPOL Preferred PLMN list AT CPOL index format oper AT CPOL AT CPOL AT CPLS Selection of preferred PLMN list AT CPLS list...

Страница 18: ...his Transmitter must not be co located or operating in conjunction with any other antenna or transmitter 2 This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body RF category Portable installation of this module is prohibited a...