background image

                 

 

 
 
 

Manuel d’utilisation 

                                   
 
 

 

 

                   

 

 

 
 
 
 
 

     

 
 
 
 
 
 
 
 
 
 
 

  KEEP THIS MANUAL FOR FUTURE NEEDS

 

 

Summary of Contents for Arcaline3

Page 1: ...Manuel d utilisation KEEP THIS MANUAL FOR FUTURE NEEDS ...

Page 2: ...SAFETY INSTRUCTIONS 2 2 FEATURES 3 3 FIXTURE OVERVIEW 5 4 DIMENSIONAL DRAWINGS 6 5 INSTALLATION 7 6 DMX 512 CONTROL CONNECTION 10 7 DEVICE DMX START ADDRESS SELECTION 11 8 DISPLAY 11 10 DMX PROTOCOL 18 11 ERROR MESSAGES 23 12 CLEANING AND MAINTENANCE 24 ...

Page 3: ...o warranty The dealer and manufacturer will not accept liability for any resulting defects or problems If the device has been exposed to temperature changes due to environmental conditions do not power on immediately The resulting condensation could damage the device Leave the device powered off until it has reached room temperature This device falls under protection class I Therefore it is essent...

Page 4: ... the technical specifications in section 2 of this manual Handle the device with care avoid shaking or using force when installing or maintaining the device When choosing the installation location please make sure that the device is not exposed to extreme heat moisture or dust If you use the quick lock cam when rigging the device make sure the quick lock fasteners are located in the quick lock hol...

Page 5: ...ions modes DMX 512 Master Slave modes Pixel Control can make extremely chasing effect Strobe effect with 1 25 flashes per second and pulse effect General dimming and blackout for all four colors IP65 outdoor use DISPLAY Advanced and convenient full color LCD touch screen Locked automatically after standby for 15 seconds to prevent error hold the button for 3 seconds to activate SOFTWARE 7 pre inst...

Page 6: ...LINE 3 User Manual XM1362 V1 0 NR 5 3 FIXTURE OVERVIEW 1 Body of the unit 2 Glass 3 Display 4 Mode esc button 5 Down button 6 Right button 7 Up button 8 Valve 9 Hook for safty cable 10 Power out 11 Power in ...

Page 7: ...ARCALINE 3 User Manual XM1362 V1 0 NR 6 4 DIMENSIONAL DRAWINGS ...

Page 8: ...r stand directly below the device when rigging de rigging or maintaining the device All electrical connections should be approved by a qualified electrician prior to using the product When the device is permanently installed these installations have to be approved by a qualified person once a year Overhead rigging requires extensive experience including but not limited to calculating working load ...

Page 9: ...ed to the unit by corresponding screws nuts clamps and hardware not included The following illustration shows an ARCALINE 3 fitted with tube clamps Important This step is very important to ensure safe rigging of the fixture 5 3 Orientation of the unit The floor stands can be installed in two different ways It is therefore possible to obtain two types of directional settings on the unit as shown in...

Page 10: ...plates each covering half of the projector s LED groups In order to install the filters each plate must be inserted into the unit on one end and both sides of the projector must therefore be opened Details of the filters installation Unscrew the three HEX screws number 1 with the help of a 2 5 mm hex key Remove the removable casing number 2 Unscrew the two screws number 3 using a Philips screwdriv...

Page 11: ...ng both HEX screws number 1 Repeat this procedure to install the second filter on the other side of the unit 6 DMX 512 CONTROL CONNECTION Connect the provided male side of the XLR cable to the female XLR output of your controller and the female side of the XLR cable to the male XLR input of the device You can connect multiple devices together in a serial fashion The cable needed should be two core...

Page 12: ...dress each unit will start to listen to the channel number you have set based on the quantity of control channels of the unit That means changing the settings of one channel will affect only the selected device In the case of the led fixtures which is a 13 channel fixture you should set the starting address of the first unit to 1 the second unit to 14 13 1 the third unit to 27 13 14 and so on 8 DI...

Page 13: ...BIN LED BIN Disp Setting Shutoff Time Flip Display Key Lock DispFlash 02 60m 05m ON OFF ON OFF ON OFF Display shutoff time Reverse 180 degree Key Lock DispFlash Flip Pixel ON OFF LED reverse order Temp C F Celsius Fahrenheit Temperature switch between Trigger DMX Value Disp Set To Slave Auto Program Auto Prog Slave1 Slave2 Slave3 Master Alone DMX Value Disp Set To Slave Auto Program ResetDefault O...

Page 14: ... modes see below 1 Tap MODE ESC button access the main menu Tap the Up Down button until Users mode set is displayed Press ENTER the display will show Users mode set 2 Choose Edit User Mode A press ENTER 3 Set Max Channel xxx the max channel 4 Set Edit User Mode B and Edit User Mode C as above 9 2 2 Edit User Mode A With this function you can adjust the rest user defined channel order 1 Tap MODE E...

Page 15: ...enu 2 Press Up Down the display will show Set Type 3 Press ENTER the display will show Set Type 4 The display show LED BIN 5 Press ENTER to confirm or press MODE ESC to return to the main menu Change TO BIN 1 Access the main menu 2 Press Up Down the display will show Change TO BIN 3 Press ENTER the display will show Change TO BIN 4 The display show LED BIN 5 Press ENTER to confirm or press MODE ES...

Page 16: ...til the display will show Display Setting Press ENTER the display will show Display Setting 2 Press Up Down the display will show Display Reverse 3 Press ENTER the display will show Display Reverse 4 The display show OFF Press Up Down the display will show ON 5 Press ENTER to confirm or press MODE ESC to return to the main menu 9 3 4 Flip Pixel 1 Tap MODE ESC button access the main menu Tap the Up...

Page 17: ...e 5 Press ENTER to confirm or press MODE ESC to return to the main menu 9 3 7 ResetDefault With this function you can select restore factory set for ON or OFF the default is OFF 1 Access the main menu 2 Press Up Down the display will show ResetDefault 3 Press ENTER the display will show ResetDefault 4 The display show OFF Press Up Down the display will show ON 5 Press ENTER to confirm or press MOD...

Page 18: ...st run time of the fixture The display shows ON or OFF Press Enter to confirm 1 Access the main menu 2 Press Up Down the display will show Clr Last Run 3 At Timer PIN menu input right password Press ENTER the display will show Clr Last Run 4 The display show OFF Press Up Down the display will show ON 5 Press ENTER to confirm or press MODE ESC to return to the main menu 9 4 2 Temp Info Head Temp Wi...

Page 19: ...lat surface wall and erform the fine lamp adjustment 1 Access the main menu 2 Press Up Down the display will show Manual Ctrl 3 Press ENTER the display will show Manual Ctrl 4 The display show PAN XXX 5 Press ENTER to confirm or press MODE ESC to return to the main menu 10 DMX PROTOCOL DMX channel s functions and their values 57DMX channels Mode Channel Value Function St B a E x Pi 1 1 Red LED all...

Page 20: ...array 12 0 255 Blue 0 Black 255 100 Blue 57 4 8 White LED array 12 0 255 White 0 Black 255 100 White 5 5 1 Shutter strobe 0 31 Led trun off 32 63 Led turn on 64 95 Strobe effect slow to fast 96 127 Led turn on 128 159 Pulse effect in sequences 160 191 Led turn on 192 223 Random strobe effect slow to fast 224 255 Led turn on 6 6 2 Dimmer intensity 0 255 Intensity 0 to 100 7 3 Color Macro 0 7 No fun...

Page 21: ...Yellow 40 44 Magenta 45 49 Cyan 50 54 Salmon 55 59 Turquoise 60 64 Light Green 65 69 Steel Blue 70 74 Orange 75 79 Straw 80 84 Pale Lavander 85 89 Pink 90 94 Red 95 99 Green 100 104 Blue 105 109 Rainbow1 110 114 Rainbow2 115 119 Rainbow3 120 124 Rainbow4 125 129 Rainbow5 130 134 Rainbow6 135 139 Rainbow7 140 144 Rainbow8 145 149 Rainbow9 150 154 Rainbow10 155 159 Rainbow11 160 164 Rainbow12 165 16...

Page 22: ...46 Chase 2 47 62 Chase 3 63 78 Chase 4 79 94 Chase 5 95 110 Chase 6 111 126 Chase 7 127 142 Chase 8 143 158 Chase 9 159 174 Chase 10 175 190 Chase 11 191 206 Chase 12 207 222 Chase 13 223 238 Chase 14 239 255 Chase 15 11 7 Chase Speed 0 125 Fast to Slow Backward 126 130 Stop Speed 0 131 255 Slow to Fast Forward 12 8 Chase Fade 0 255 Fade Chase 13 9 internal programs 0 79 Normal 80 84 no function 8...

Page 23: ... of EEPROM 120 139 Internal program 2 secne9 16 of EEPROM 140 159 Internal program 3 secne17 24 of EEPROM 160 179 Internal program 4 secne25 32 of EEPROM 180 199 Internal program 5 secne33 40 of EEPROM 200 219 Internal program 6 secne41 48 of EEPROM 220 239 Internal program 7 secne49 56 of EEPROM 240 255 Reserved ...

Page 24: ...N movement is not located in the default position after the reset TILT movement Er TILT head movement error This message will appear after the reset of the fixture if the head s magnetic indexing circuit malfunctions Optical Sensor or Magnetic Sensor fails or the stepper motor is defective or its driving IC on the main PCB The TILT movement is not located in the default position after the reset ZO...

Page 25: ...ndition and does not fail prematurely we suggest regular maintenance 1 Clean the inside and outside lens each week to avoid loss of output due to accumulation of dust dirt on the lens 2 Clean the fans each week to ensure maximum airflow and efficient thermal cooling This will ensure the light source is operated in the best possible condition 3 A detailed electrical check by an approved electrician...