background image

INSTALLATION AND OPERATION MANUAL

HSMIX

v

2

INSTALLATION MIXER

Summary of Contents for HSMIXv2

Page 1: ...INSTALLATION AND OPERATION MANUAL HSMIXv2 INSTALLATION MIXER ...

Page 2: ...1 LISEZ ces instructions 2 Tenez ces instructions 3 Notez tous les avertissements 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes sources de chaleur comme radiateurs regi...

Page 3: ...ER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance For European Union countries This symbol on the product or its packaging indicates that this product must not be dispos...

Page 4: ...table volume controls to prevent end user tampering 1RU height with front rack mount ears TERM MEANING TONE Typically an alarm or alert which bypasses the pre amplifier master control stage MUSIC Audio MP3 or WAV music files which are not used as Tones MP3 Lossy data compression audio coding format WAV Waveform audio file format XLR Audio electrical connector type RCA Audio electrical connector ty...

Page 5: ... occurs adjust the gain trim potentiometer of the corresponding channel counter clockwise until the green LED is illuminated 5 MASTER OUTPUT METER The LEDs will illuminate in sequence from 40dB to 10dB level based on the input signal level to the mixer The red LED will illuminate when clipping occurs turn down the master volume to prevent clipping 6 SD CARD CONNECTOR Input connector for a full siz...

Page 6: ... Bass 100Hz 12dB Mid 1600Hz 12dB Treble 10kHz 12dB 14 DEFEAT VOLUME CONTROL You can defeat disable the mixer s volume controls to prevent end users interfering with the system volume Place the DIP switch in the DOWN position to disable the volume control Use the GAIN TRIM potentiometer to modify the audio level instead of the volume controls during installation WARNING Disabling the volume control...

Page 7: ...ut 12V phantom power on the corresponding XLR balanced input connector Phantom power is NOT outputted on the RCA connectors Note To avoid potentially damaging audio spikes to connected equipment turn off the product before enabling phantom power 7 RECORD OUTPUT A standard stereo RCA output containing the pre master mixer stage output signal i e Pre Master volume control potentiometer Pre Amplifier...

Page 8: ...N EQUALISER VCA MASTER LEVEL CONTROL POT DEFEAT BALANCED OUTPUT MASTER METER CH1 6 BLUETOOTH MUSIC PLAYER 500kΩ External Pot LINE IN PRE AMP STAGE RCA INPUT XLR INPUT 12V PHANTOM SIGNAL PRESENCE GREEN LED 12DB GAIN EQUALISER CHANNEL LEVEL CONTROL POT DEFEAT PRIORITY CONTROL MUTING CH1 3 BLOCK DIAGRAM ...

Page 9: ...hrough the wire produces a voltage drop due to the wire s resistance This voltage difference between the mixer earth and source equipment earth appears to the mixer s input as a signal and is amplified as hum There are three things you can do to avoid earth loop problems Ensure the mains power for the audio system is quiet i e without equipment on it such as air conditioning refrigeration or light...

Page 10: ...the highest signal level possible i e for a CD player cassette deck or other music source put on the loudest anticipated program music or for a paging mic make a loud page During this signal condition the input status LED should light green and may occasionally turn red for a short period If the status LED stays red more than 10 of the time you should reduce the input GAIN TRIM If the status LED n...

Page 11: ...the volume control stages of the HSMIX CHANNEL GAIN POT CHANNEL VOLUME BLUETOOTH MOBILE DEVICE 1 VOLUME IN FILE NAME 1 VOLUME IN FILE NAME 2 VOLUME TXT IN FOLDER 2 VOLUME TXT IN FOLDER PLAY MUSIC PLAY TONE 3 FRONT PANEL SETTING 3 TONE VOLUME POT RC1 VCA optional MASTER GAIN POT VCA MASTER VOLUME ...

Page 12: ...ging preannounce Triggered by shorting CHIME to GND it will sound only once for each time the trigger is activated Please note CHIME tone must play to completion before it may be retriggered To activate a tone trigger input short the relevant input to GND The selection must be stable for longer than 150ms Each tone is played to completion even if the trigger selection is removed during playback A ...

Page 13: ... fault code will flash on the STATUS LED and the default tone will be played instead with a volume level set by the TONE VOLUME POT USER DEFINED TONES USING AN SD CARD The HSMIX s tone generator features can be extended beyond the EVAC ALERT INTRUDER BELL and CHIME tones Additional user generated tones can be placed on an SD card and played using the back panel 10 way Phoenix connector NOTE It is ...

Page 14: ...OPEN GND GND OPEN Play file 6 6_abc_xxx wav Repeat while selected GND GND GND GND OPEN OPEN Play file 7 7_abc_xxx wav Repeat while selected GND GND GND OPEN GND OPEN Play file 8 8_abc_xxx wav Repeat while selected GND GND OPEN GND GND OPEN Play file 9 9_abc_xxx wav Repeat while selected GND OPEN GND GND GND OPEN Play file 10 10_abc_xxx wav Repeat while selected GND GND GND GND GND OPEN Play file 1...

Page 15: ...ority when audio is detected 2 RELEASE TIME There are two controls used in combination to set the release unmute time DIP switch R sets the adjustable range of the RELEASE TIME POT OFF 1 5 seconds ON 1 25 seconds RELEASE TIME POT Set this trim pot to the desired release unmute time after a priority channel audio signal is no longer present Turn clockwise to increase the release time 3 LEVEL THRESH...

Page 16: ...le in the selected folder from the SD Card When playing pause the playback When paused continue playing from when pause occurred Next Track When playing skip to the start of the next file in the selected folder on the SD Card Previous Track When playing skip to the start of the previous file played If no previous file exists restart current file LONG PRESS ACTION BUTTON ACTION Swap Folder Swap bet...

Page 17: ... the Bluetooth module off BLUETOOTH CONNECTION RANGE The Bluetooth connection range is a minimum of 10 meters However range is typically much larger but not guaranteed CONNECTING A DIFFERENT BLUETOOTH DEVICE The Bluetooth module can only support one device connection at a time If you need to change devices repeat the Bluetooth connection process described above By entering pairing mode it disconne...

Page 18: ...Step 1 Download install and open the Bluetooth Control Software from the Australian Monitor website Step 2 Select the HSv2 product from the product selector Step 3 Enter the required Bluetooth configuration Step 4 Select Export Bluetooth Configuration button and save the file to the ROOT of an SD card Step 5 Turn OFF the HSMIXv2 mixer amplifier and insert the SD card Step 6 Turn ON the HSMIXv2 mix...

Page 19: ...4 seconds to show the product is in standby mode While in standby mode the following will still be active 1 EVAC ALERT INTRUDER tone trigger inputs Triggering any of these inputs will cause the device to exit Standby Mode and play the Tone When the tone trigger is released the mixer will re enter standby mode immediately USB CHARGING The USB charging port is provided to charge mobile devices It pr...

Page 20: ... the root of the SD card with the tone name and optional volume setting in the filename File Format Tonename _ Volume mp3 Valid Tonenames are evac alert intruder bell or chime Examples evac mp3 overrides the inbuilt EVAC tone with this file alert_75 wav overrides the inbuilt ALERT tone with this file and set volume to 75 USER DEFINED TONES To add user defined tones place an MP3 or WAV file on the ...

Page 21: ...to set each filename within the sequence folder 1 Create a text file named volume txt 2 Enter a value from 1 to 100 inside the text file NOTE If a track has a volume specified in its track name this will supersede the folder volume setting in the volume txt file Example OPERATION CONT File Format Trigger Number _ Track Name _ mixN_Volume mp3 In order to activate the priority mode for an individual...

Page 22: ...w to apply this setting NOTE If a track has a volume specified in its track name this will supersede the folder volume setting in the volume txt file SD CARD CONTENTS EXAMPLE Folder File Structure Example All files and folders are optional If the mixer tries to read a file or folder selection that does not exist on the SD card it will flash an error on the STATUS LED SUPPORT OF SD CARDS LARGER THA...

Page 23: ...or is named incorrectly Check the SD card folder is present and named correctly 3 SD card file error The mixer is trying to access a file on the SD card that does not exist or is named incorrectly Check the file on the SD card file is present named correctly and is a supported file format See SD card format section 4 NOR flash image failure NOR flash image failure Please return mixer to your neare...

Page 24: ...ction be carried out annually by a qualified technician FIRE REGULATION COMPLIANCE This mixer is not certified to fire regulations standards such as EN 54 16 FAULT FINDING PROTECT INDICATOR The following table indicates the meaning of each protection mode LED MEANING RESOLUTION Red Yellow flashing USB power fault A mobile device has attempted to draw too much current Please remove the device from ...

Page 25: ...mV Equaliser and Gain set to mid position Channel volume to maximum RECORD OUT 12dBu 200mV Input channel maximum and Master volume set to mid 10kΩ termination LINE OUT 0dBu 0 775V Input channel maximum and Master volume set to mid 1kΩ balanced termination LINE OUT MAX 10dBu 2 45V Input channel maximum and Master volume set to maximum 1kΩ balanced termination GAIN TRIM 12dB CHANNEL EQUALISER 100Hz ...

Page 26: ... D X H 483mm x 180mm x 44mm 19 x 7 09 x 1 73 PRODUCT DIMENSIONS WITHOUT RACK EARS W X D X H 438mm x 180mm x 44mm 17 24 x 7 09 x 1 73 SHIPPING DIMENSIONS W X D X H 505mm x 290mm x 95mm 19 9 x 11 4 x 3 7 NET WEIGHT 2 4 Kg 5 3 lbs SHIPPING WEIGHT 3Kg 6 6 lbs MOUNTING 1 RU OPERATING TEMPERATURE 0 C to 40 C 95 RH FINISH ALL MODELS Powder coated steel ALU front panel COLOUR ALL MODELS Black ACCESSORIES ...

Page 27: ...se of the firmware BASIC UPDATE PROCEDURE Using a USB to 3V3 UART bridge e g Silabs CP2102 connect the UART bridge to the 10 way Phoenix LOGIC connector as follows WARNING DO NOT USE A 5V UART BRIDGE This could permanently damage the product USB to UART cable Terminal Block HSMIX LOGIC connector 1 VOX 2 STANDBY 3 VCA GND of UART Bridge 4 GND RXD of UART Bridge 5 EVAC TXD of UART Bridge 6 ALERT 7 I...

Page 28: ...D BY AUSTRALIAN MONITOR Address Unit 1 2 Daydream Street Warriewood NSW 2102 Australia Website www australianmonitor com au International enquiries email international australianmonitor com au ABN 86 003 231 187 ...

Reviews: