Page 1: ...www atronic com Atronic Cashline Slant Top AST Installation Manual Rev 2 3 February 2008 ...

Page 2: ...ributed transmitted transcribed stored in a retrieval system or translated into any human or computer language in any form or by any means electronic mechanical magnetic manual or otherwise or disclosed to third parties without the express written permission obtained from a properly authorized official of Atronic DISCLAIMER Atronic makes no representation or warranties express or implied with resp...

Page 3: ...uctions Machine Components Dimensions Technical Data Machine Installation Overview Inspection Mount Toplight Replace Shipping Locks Prepare Coin Acceptor Prepare Hopper Check Cables and Connectors Check Commboard Settings Apply Power Switch On Basic Setup Overview only Tests Technical Support Telephone Numbers 4 5 7 10 12 13 15 16 16 16 17 17 17 18 18 18 19 20 21 CONTENT ...

Page 4: ...chnical data and cabinet drawings Target Audience We address qualified technical personnel who are involved in installation setup and configuration of Atronic gaming machines With this user group we assume that they are basically familiar with gaming machines and casino related terminology Please read this document and the contained safety notes carefully before you start machine installation Incl...

Page 5: ... Software Manual P Level Operation Manuals Cashline Operating Manual O Level Cashline Operating Manual P Level Spare Parts Atronic Cashline Slant Top Parts Catalogue Peripherals Coin and bill acceptors hopper printer etc See folder Peripherals on the Atronic Service Manual CD Note All mentioned manuals can be found on a CD ROM titled Atronic Service Manual 2008 If this manual did not came with thi...

Page 6: ...6 February 2008 Cashline Slant Top AST Installation Manual blank page ...

Page 7: ...opper when working on it Precautions before operating The machine weighs about 100kg 220 lb At least two persons should carry or lift it Use a cart to transport the machine Check that all connectors are seated correctly Fal se connections can cause irreparable damage not covered by warranty Verify voltage specifications stated on type plate before connecting to a main power socket Machine must be ...

Page 8: ...ed with the power switched off Use only original Atronic parts for replacement Atronic Commboard Danger of explosion if battery is incorrectly repla ced Check for correct polarity and replace with the same or equivalent type only Please refer to the Atronic Service Manual CD for further instructions on service and maintenance Additional Information The X rays which develop in this machine are suff...

Page 9: ...9 February 2008 Cashline Slant Top AST Installation Manual blank page ...

Page 10: ...pper Board Power Board Bill Validator Unit w Bill Head Stacker Bill Door Switch Coin Bowl Bill Door Lock Jackpot Key Audit Key Hardmeters Coin Validator Bill Door Drop Drawer Power Supply Drop Drawer Switch Main Door Switch Main Door Lock Power Switch Button Board Monitor Upper Main Door Lower Main Door Top Box w Toplight Top Box Lock MACHINE COMPONENTS ...

Page 11: ... access bills Bill Acceptor Housing Locks Allows to remove the bill stacker from the validator enclosure Main Door Switch Registers all main door openings Power Switch Switches power supply on off Logic Door Lock and Switch Unlock the logic door lock to get access to the boards The optional logic door switch detects logiv box openings Service Switch green Pressing the service switch activates the ...

Page 12: ...mm 26 4 Depth 850 mm 33 5 DIMENSIONS 1582mm 62 3 840mm 33 1 1435mm 56 5 670mm 26 4 628mm 24 7 630mm 24 8 850mm 33 5 160mm 6 3 1066mm 42 2011mm 79 2 840mm 33 1 1435mm 56 5 670mm 26 4 630mm 24 8 850mm 33 5 1066mm 42 Cabinet AST Cashline with Topper Weight approx 104 Kg 227 lbs Height 2011 mm 79 2 Width 670 mm 26 4 Depth 850 mm 33 5 DIMENSIONS ...

Page 13: ...ower Supply F 5A 250V Monitor T 3A 250V Power Board T 2A 250V Backplane F1 5V T 5A 250V Backplane F2 12V T 5A 250V Backplane F3 12V T 0 315A 250V Backplane F4 24V T 3 15A 250V Lamps Fluorescent Lamps 15W 17 438 mm 8W 11 285 mm Button Lamps small 14V 1W Button Lamps large 14V 2W Environmental Specifications Operating Temperature 32 F 0 C 113 F 45 C Operating Humidity 0 to 85 Combustible Weight 33 l...

Page 14: ...14 February 2008 Cashline Slant Top AST Installation Manual blank page ...

Page 15: ...ct paytable glasses hardware configuration and that the software EPROMs are correctly installed on the PCBs Install the toplight Replace shipping locks with casino specific locks Install and connect online accounting system Prepare coin comparator and hopper Check that all internal and external connections are seated correctly Apply power to the machine Load paper into the printer Execute basic ma...

Page 16: ...nected from the main power socket before the machine is free from electrical current The power switch is intended for service purposes only Install Toplight Open top box Run the toplight harness through the opening on top Fix the toplight with four screws Connect the toplight Molex connector Replace shipping locks Atronic machines are equipped with shipping locks for easy commisioning These locks ...

Page 17: ...coins and re adjust if necessary See manuals Peripherals Coin Acceptors for details Prepare Hopper The hopper high level switch detects the filling level of the hopper by the weight of the coins When the switch is activated further accepted coins are separated to the drop box The switching threshold can be altered with an adjustment screw Fill the hopper with that amount of coins tokens at which y...

Page 18: ...et Connect main cable to a grounded main power socket that is capable to deliver the specified cur rent rating Switch on the machine Press the power switch to switch on the machine The LED s on the masterboard they indicate cor rect voltages should all be lit To operate the machine while main door is open pull the main door switch to set it to closed position Execute basic machine setup if needed ...

Page 19: ...nt of the logic box Service Menu has following options Set Clock Service Menu Menu Setup has following options Toplight Hopper Payout Limit Change Language Double Up Setup Bills Enabled Animation Mode Sound Win Presentation Jackpot Music Volume System Lockup Options Voucher Redemption Sound Menu Volume Set Celebration Limit Change Token Window Denomination Window Residual Handling With Card See ma...

Page 20: ... main page and select Hopper Out Test hopper payout and switching times Hopper Out Run HOPPER SWITCH TEST by pressing the left lit button for 4 sec Hopper will perform a coin out until it is empty or the teset Button is pressed The switching period values in msec are displayed If any of the values is below 12 msec the Hopper count switch has to be re adjusted See manual Peripherals Hopper for deta...

Page 21: ...tive at one of the numbers below If technical assistance is required outside of normal business hours please contact one of the Atronic Technical Hotline numbers below Technical Support Locations Atronic Germany International Headquarter 49 5741 273 720 Atronic Peru 51 161 832 00 Atronic United Kingdom 44 1727 855 966 Atronic Russia 7 495 7377 299 Atronic Technical Hotline numbers For technical as...

Reviews: