background image

User manual

ENGLISH

ATMOS HAZE 1400

Version 1.0

Summary of Contents for HAZE 1400

Page 1: ...User manual ENGLISH ATMOS HAZE 1400 Version 1 0 ...

Page 2: ...oth Other Abnormal Situations Maintenance Product Specification 21 CONTENTS If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Read the manual Indoor use only This symbol indicating separate collection for electrical and electronic equipment Warning situations that could cause injury to yourself or other...

Page 3: ...ut it in tilted place Before moving machine always drain fog fluid into the tank and tighten the tank cap securely to avoid spilling Thank you for selecting our Atmos serials DMX Haze machine you already own the high tech professional DMX Haze Better read the manual thoroughly before operation follow instruction will help you have a smooth handling with Atmos serials DMX Haze machine to achieve th...

Page 4: ...e directly at people Keep case closed while operating Put Haze machine in drafty place Do not insert objects into air vents Allow 20cm space or above around the machine for proper ventilation Keep Haze machine away from flames and flammable items Never aim the nozzle at open flames or sparks Use only high quality water based Haze fluid Never put flammable substances into the tank Machine must cool...

Page 5: ...d If ingested call a doctor immediately If fluid contacts eyes or skin rinse skin thoroughly with water Read user manual instructions thoroughly before operating Follow the instruction Never remove warning or informative labels from the unit Important Safeguards Read all instruction Products for indoor use only Keep away from liquids Never operate in rain or in damp conditions Unit must be grounde...

Page 6: ...instructed on the user manual If accident happens because users do not install the product according to the instruction of the user manual the manufacturer will not take any responsibility Please note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Important The wires in this mains lead are colored in accordance with...

Page 7: ... screen E 6 Buttons Figure1 ATMOS HAZE 1400 Functions A C B D O M E N M F DMX 5 pin XLR Output G DMX 5 pin XLR Input H DMX 3 pin XLR Output I DMX 3 pin XLR Input J Fuse Holder or NFB K Electric Power Input L Fog Output Nozzle M Sponge N Cushion O Fan Net F N G H I J K M L L ...

Page 8: ...r when performance is ongoing DMX on board 3 DMX modes for choice 1CH 2CH 4CH operate by any additional DMX controller Multi function operation control Built In timer control manual fogging control and continuous fogging control Heavy duty Able to keep working long time Self cleaning function The machine design of machine stops working after a delay of 30 seconds automatically clear the tubing of ...

Page 9: ... 3 Set the Haze machine on a dry flat surface 4 Connect the quick connector with the liquid tank cap Figure 1 C Be sure of well connection Use definitely water based liquid of good quality 5 Plug mains power cord from the Haze machine into appropriate power supply socket Wait about 60 seconds for heating element to heat up 6 Use LCD display for operating control or connect DMX controller for setti...

Page 10: ...rmation 5 pin XLR 3 pin XLR 1 Ground 1 Ground 1 Ground 1 Ground 2 Cold 2 Cold 2 Cold 2 Cold 3 Hot 3 Hot 3 Hot 3 Hot 4 N A 4 N A 5 N A 5 N A XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment negative Pin 3 Data True positive Pin 4 No use Pin 5 No use XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment negative Pin 3 Data True positive ...

Page 11: ...d fast pressed UP DOWN at the same time value back to 1 Vol xxx Setting output of timing fogging and continuous Fogging Volume 5 100 Fan xxx Setting fan speed of timing fogging and Continuous Fogging Fan 5 100 DUR xxx Setting duration of timing fogging Duration 3 250s INT xxx Setting interval of timing fogging Interval 5 250s Fan Speed Volume Adjustment Increasing numerical value for Function Decr...

Page 12: ... speed fogging Release Manual to recover previous status This function can be started forcedly under any status Self cleaning function The machine design of machine stops working after a delay of 30 seconds automatically clear the tubing of the remaining liquid If wanting to expedite liquid supply when powered on the machine using function of manual fogging can help Set values are automatically sa...

Page 13: ...off The picture shows the new machine default state REMARK To reduce the possibility of that the wind mouth gets humid the software will detect the wind value and the fog value and do proper adjustment Under display control mode timing fogging continuous fogging and manual fogging or DMX control mode when fog value is adjusted to 100 the software will adjust wind value even it is set at 5 to 30 au...

Page 14: ...ing fogging Please note the machine design of machine stops working after a delay of 30 seconds automatically clear the tubing of the remaining liquid 2 Under this status press Function to get into timing setting menu please note timing fogging stops at the same moment 4 Press again Function to switch to adjust the value of Interval please note timing fogging still stops at the same moment If want...

Page 15: ... of machine stops working after a delay of 30 seconds automatically clear the tubing of the remaining liquid After the Self cleaning process is complete return to the previous picture status 3 Press Function to switch to adjust the speed of fan please note continuous fogging still works at the same moment If wanting to expedite liquid supply when powered on the machine using function of manual fog...

Page 16: ...n of functions list directly Press Up or Down to move up or down press again Function to enter the function selected by and setting the menu like previous timing fogging mode or continuous fogging mode There is no operator action for two seconds then automatically revert to the previous status 2 Release Manual to recover previous status 1 Connect the DMX 512 controller cable to the input socket G ...

Page 17: ...nd interval value 9 Please switch the DMX mode 1ch 2ch or 4ch by Function 10 If desired connect another Haze machine Plug one end of another signal cable in to the output socket F or H of figure 1 on the back of the first ATMOS plug the other end of the signal cable to the input socket G or I of figure 1 on the back of the second ATMOS Follow the same procedure to link more fog machine if desired ...

Page 18: ... 0 4 Volume 0 Fan 5 CH1 CH2 Volume Fan 5 255 5 100 16 255 6 100 0 4 Off 0 15 5 1 CH 2 CH 4 CH CH1 CH2 CH3 CH4 Volume Fan Duration Interval 5 255 5 100 16 255 6 100 8 255 3 250 s 10 255 5 250 s 0 4 Off 0 15 5 0 7 3 s 0 9 0 s Interval 0 means constant fog ...

Page 19: ...ing 6 Check your controller if in correct connection 7 Check your DMX address setting Power Connected Fog Blasts not Smooth Moving the machine during operation could probably get air entered into the liquid pipe and affect smoothness of fog blasts If this happened use Manual function to force the machine to fog for a moment Until the air is dispersed from the pipe the machine will recover its norm...

Page 20: ...f the Haze machine tank immediately after filling 2 Prolonged use the nozzle may be clogging by impurities periodically use tools to clean the nozzles keep the nozzle unobstructed Other Abnormal Situations Heater Overheat No Heating No Fluid Flashing and showing this status means heater is too hot or thermos sensor is cut Flashing and showing this status means unable heating Flashing and showing t...

Page 21: ...ver and remove the air filter to do the cleaning after cleaning be sure to dry the air filter after replacing the flight case again 4 Prolonged use sponge inside the vent may accumulate oil periodically cleaned out or replaced with a new sponge Be sure to dry the air filter after replacing the flight case again ...

Page 22: ...k tight the connections carefully with proper tool 6 PC board should be kept from being dirtied with oil In case this happened dismantle carefully the PCB and have it brushed clean both sides with dilute alcohol Leave it dry itself then install it back Make sure all wires are well connected 7 Clean the metal cover with dry cloth ...

Page 23: ...4CH Built in Function Timing Fogging Continuous Fogging Manual Fogging Fuse 120V NFB 16A Fuse 230V 240V NFB 10A Display Blue LCD Screen Tank liters 5 6L Fog Output cu ft min 15000 Warm Up time seconds 60 Fluid Consumption ml min Max output 16ml min Min output 0 45ml min Date Connection 3P or 5P XLR Low Fluid Shutdown Yes Bracket Yes Voltage 120V 60Hz 230V 240V 50Hz Dimensions LxWxH w o bracket 394...

Page 24: ...ATM OS Save this instruction properly All the information is subject to change without prior notice ...

Reviews: