background image

◆ 

Features

• 12~24 VAC/VDC operation

• 1,010 User codes

• 2 Form C relays, each rated 10A@30VDC

• Each relay has programmable output time from 1~99 seconds or toggle

• Output #2 can be programmed for use with a door bell

• 2 Egress inputs for exiting the premises without keying in the code

• Split controller installation protects the keypad access from magnet tampering

• Accommodate a Two Man Rule by cascading 2 relays.

• Backlit keys for easy nighttime use

• Able to mount to a single-gang back box

• Door sensor input for anti-tailgating operation

• All features are programmed directly from the keypad - no need for an external programmer

• EEPROM memory protects programmed information in case of power loss

• Tamper contact for added security

• Circuitry is potted with epoxy for outdoor use

• IP65 weatherproof rating, rugged zinc alloy construction

DG-750

Access Keypad with Split Controller

2 3/4” (69.5mm)

1/8” (60.3mm)

1/4” (6mm)

4 13/16”(122.8mm)

7/8” (22.8mm)

3 1/16” (78.5mm)

Copyright © All rights reserved. P-MU-DG-750  Published 2019.07.01

Summary of Contents for DG-750

Page 1: ...lays Backlit keys for easy nighttime use Able to mount to a single gang back box Door sensor input for anti tailgating operation All features are programmed directly from the keypad no need for an external programmer EEPROM memory protects programmed information in case of power loss Tamper contact for added security Circuitry is potted with epoxy for outdoor use IP65 weatherproof rating rugged zi...

Page 2: ...4 140 F 20 60 C LED Indicators Audible Indicators Audible Tone 1 Long tone 1 Short tone 3 Short tone Keypad Status Confirmation Key press User code denied 6 Short 1 Long tone All user codes deleted LED Steady Amber Programming Mode Keypad Status Flashing Amber Waiting to programming entry Steady Green Waiting to program card code Steady Red Card code already present Steady Green Relay 1 activated ...

Page 3: ...ED Solid Green Awaiting code entry If you are unsure of which mode the keypad is in press until the LED is off The keypad is now in the Standby Mode Enter the master code twice to return to Programming Mode Copyright All rights reserved P MU DG 750 Published 2019 07 01 Model DBR 200 COM NO INPUT AC DC To Keypad To Keypad 12VDC 12VDC 12 VDC Sample wiring and applications Relay 2 Relay 1 Electric Lo...

Page 4: ...gth 4 digits 5 digits 6 digits New Master Code 1234 12345 123456 C Program the Master Code 1 Enter Programming Mode by entering the Master Code twice Default Master Code is 1234 2 Enter 3 3 Enter the new Master Code twice The Master Code may not be the same as a user code Example If the desired new Master Code is 4321 enter 4 3 2 1 4 3 2 1 4 Exit Programming Mode by pressing Programming Output 1 N...

Page 5: ...ID number 0 0 0 to 9 9 9 Step 2 Delete existing user by entering Step 3 Enter a new user code x x x x or Return to Programming Mode by entering Deleting or Changing an Output 2 User Step 1 Enter 4 Step 2 Enter a user ID number 0 0 to 0 9 Step 3 Delete existing user by entering Step 4 Enter a new user code x x x x or Return to Programming Mode by entering Additional Programming Programming the Outp...

Page 6: ...ame Restore Factory Settings Enter 8 9 9 IMPORTANT Once key entry is made keypad will return to factory default settings No user information will be retained and the Master Code will be 1234 Manually Resetting the Master Code If the Master Code has been forgotten or does no work the following steps can be taken to reset the Master Code 1 Disconnect power from the keypad 2 Press the key continuousl...

Reviews: