D339-G / D839-G

Motor: 

Part No:

D339-G 88935XXXX 

D839-G 88955XXXX

Operating Manual

D339-G / D839-G

Publication Ref: 171124

Betriebsanleitung

D339-G / D839-G

Publikation Ref: 171124

Dunkermotoren GmbH | Allmendstraße 11 | D-79848 Bonndorf/Schwarzwald

Phone +49 (0) 7703 930-0 | Fax +49 (0) 7703 930-210 | [email protected]

Version 1

1/2017

Summary of Contents for Dunkermotoren D339-G

Page 1: ...XX Operating Manual D339 G D839 G Publication Ref 171124 Betriebsanleitung D339 G D839 G Publikation Ref 171124 Dunkermotoren GmbH Allmendstra e 11 D 79848 Bonndorf Schwarzwald Phone 49 0 7703 930 0 F...

Page 2: ...d with an incremental encoder Its signals can be evalu ated by an external control device Betriebsanleitung D339 G D839 G 1 Allgemeine Beschreibung Dies ist eine Original Betriebsanleitung der Dunkerm...

Page 3: ...rection and at the same time push the ad justment button 2 Up for the time the ve netian blind moved approx 0 5 m about 15 sec After this time the adjustment button remains snapped Continue to run the...

Page 4: ...Sek gedr ckt halten danach selbsthaltend Jalousie weiter in AB Richtung in die ge w nschte Endlage fahren Feineinstellung durch Tippen am Taster m glich Mit AUF Befehl Endlageneinstellung fixie ren de...

Page 5: ...4VDC erfol gen H here Spannngen f hren zur Besch digung des Gebers The power supply of the incremental encoder has to be done with safety extra low voltage SELV in the range of 8VDC to 24VDC Higher vo...

Page 6: ...ene Personen und Sachsch den NOTICE WARNING If the device is not used in ac cordance with the designated use the manufacturer is not liable for personal injury and or damage to property HINWEIS WARNUN...

Page 7: ...tinuous running The engine ratings were determined at an ambient temperature of 20 C Different ambient tempera tures lead to different ratings The drive must not come into contact with agressive media...

Page 8: ...r Halten Sie Personen solange von der Anlage fern bis diese still steht Bei Arbeiten an der Anlage Wartung Fen ster putzen trennen Sie stets die Anlage vom Versorgungsnetz Der A bewertete Emissionssch...

Page 9: ...enerally applicable regulations VDE have to be complied with for the installation For installation all pole disconnection from the mains with a contact gap of at least 3 mm per pole is required Before...

Page 10: ...eb zweier Jalousieantriebe ist grunds tzlich ein zweipoliger Schalter zu verwenden und der Anschlu entsprechend Bild 2 vorzunehmen Ein direktes Umschalten der Laufrichtung ist zu vermeiden Es sind ent...