background image

Electric Bolt

EB1001 - Instructions

15

126.5

203

57.5

9.5

40

14

172

3

AU

TO

LO

CK

TIM

ED

EL

AY

SE

TT

ING

0

SE

C

3

SE

C

6

SE

C

9

SE

C

1

2

ON OF

F

1

2

ON OF

F

1

2

ON OF

F

1

2

ON OF

F

17

9.5

TECHNICAL INFORMATION

Power to Lock/Fail open.

Stainless steel bolt - diameter 15mm

- throw 15mm

Voltage required

12vDC

Activating current

1.0A

Holding current

250 mA

Fully protected against transients and
reverse polarity

The Autolock Time Delay can be set for
0, 3, 6 or 9 seconds.

Monitoring - Door position switch (DSS)

- Bolt position indicator

GENERAL INSTALLATION
INSTRUCTIONS

Ensure you have the following:-

- Strike plate

- Electric bolt

All rebate strips and/or frame stops
should be fitted before starting.

A 2 amp Power Supply should be
provided to ensure there is a Full 1
amp for the bolt. This should allow for
a basic Access System and a back up
battery to be connected to the same
source.

WARNING - THE CONNECTION
OF AN INCORRECT VOLTAGE
MAY RESULT IN DAMAGE NOT
COVERED BY THE PRODUCT
WARRANTY.

The selection of appropriate power
supply cable is very important to
ensure lock receives sufficient power
to operate.

First Choice for

Locking Solutions

01202 676262

01202 680101

[email protected]

www.alpro.co.uk

T

F

E

W

1

2

4

3

alpro

®

Bolt Face Plate 203 x 34 x 3mm

Strike Plate 98 x 34 x 3mm

EB1001 Instructions_A5:EB501-22 Instructions  1/8/07  17:53  Page 1

Reviews: