Applicable for: 600W, 800W, 1200W 

 

Summary of Contents for FTS600P

Page 1: ...DC TO AC POWER INVERTER INSTRUCTION MANUAL FTS600P FTS800P FTS1200P Applicable for 600W 800W 1200W ...

Page 2: ... input under voltage protection input over voltage protection overload protection over temperature protection output short circuit protection Please read this carefully before using Features and Application Pure sine wave output High efficient and portable Intelligent fan control Advanced microprocessor design With low voltage high voltage overload short circuit and overheat protection Ⅱ Products ...

Page 3: ...t of inverter Note For better operation we recommend consumer to use with battery that exceeds 100AH Ⅳ Application 1 Scope of application a Only use for class Ⅱ appliances Electric power tool series Electric Saw Drill Sander etc Office equipment Computers printers displays scanners facsimile apparatus Household appliances Vacuum cleaner fan fluorescent lamp filament lamp sewing machine Kitchen ser...

Page 4: ...rge with the inverters USB port 2 Usage a The inverters input voltage must be same as battery s voltage The appliance s working voltage must be same as inverters output voltage once all are the same connect them in right way based on Connection Explanation of the manual b Please use the inverter in ventilated areas and make sure the fan is not blocked c Do not put the inverter in rain or in humid ...

Page 5: ...n using in cars please don t run the inverter while the engine has stopped 4 Please do not open the inverter for service please use a professional to mend it Ⅴ Safety 1 Please do not operate the inverter while your hands are wet Keep it away from children 2 The temperature of the shell will be high after extended use so do not touch it in case of scalding 3 Do not put metal objects into the invert...

Page 6: ...e battery returns to the related voltage the inverter will start working green light will go on red light will go off Over load protection Green on Red on No alarm No AC output Reduce the load to acceptable range theinverter will start working green light will go on red light will go off Over temperature shut down Green on Red on Alarm No AC output When the inside temperature returns to acceptable...

Page 7: ... rate 3 Effiency 85 No load current 0 95A Input under voltage alarm 12V input DC 10 2 10 8V Input under voltage shut down 12V input DC 9 2 9 8V Input over voltage shut down 12V input DC 15 16V Overload shut down 660W 780W 960W 1060W 1300W 1500W Working temperature 5 35 Heat dissipation method fans Cable Red Black Battery Cable Technical Assistance If you need assistance Aerpro Inverter now or in t...