Technical Specifications

Recessed

Surface Mounted

Power supply

Self-Contained:

 230-240V 50Hz

Self-Contained:

 230-240V 50Hz

 

Slave: 

220-240V AC / 176-275V DC

Slave: 

220-240V AC / 176-275V DC

Autonomy

3 hours

3 hours

Commissioning time

60 hours

60 hours

Ambient temperature

Self-Contained:

 +5°C ... +35°C   

Slave:

 0°C ... +40°C

Self-Contained:

 +5°C ... +35°C   

Slave:

 0°C ... +40°C

Protection class

II

II

Degree of protection

IP42/IP20 (below ceiling/above ceiling)

IP54

Battery

NiMH 4,8V - 2,0Ah (

Self Contained

)

NiMH 4,8V - 2,0Ah (

Self Contained

)

Lightsource

2 LED’s (2 x 0, 85W = 1,9W)

2 LED’s (2 x 0, 85W = 1,9W)

Compliance

ENGLISH

Carefully read this instruction leaflet before installing or using the luminaire. This leaflet 

provides important information about the correct installation, use, maintenance and dis-

posal of this product.

Please observe the following guidelines:

1.   The luminaire should only be installed by qualified personnel and installation must be 

  in accordance with European installation requirements HD 60364 and additional 

  local regulations.

2.   This product may not be modified in any way what so ever or used for a purpose or in an

  environment other than for which it is designed. Failling to observe these guidelines 

  will invalidate the warranty and the CE-compliance of this product.

3.   The luminaire is suitable for indoors use only.

4.   Before installing the luminaire, the supply must be isolated.

5.   The lightsource in this luminare is not replaceable;  when the luminaire reaches end of 

life the whole luminaire shall be replaced.

INSTALLING AND CONNECTING

The luminaire should be connected to the voltage equivalent to that indicated on the 

type label. The surface mounted luminaire is fitted with a terminal block suitable 

for loop-in-loop-out connection. For further information on the different connection 

possibilities, see the instructions in this instruction leaflet.

SELF-TESTING

All self contained versions of this luminaire are equipped with an automatic self-testing 

system that continuously monitors battery operation, the light source(s) and the electronics. 

The amber LED’s will indicate when one of these components is not working properly. 

To prevent all luminares to start the test sequence at the same time, an odd and even function 

is available. All even luminares start the test sequence as normal; all odd luminares start 

the test sequence 24 hours later. The luminaire can also be tested manually with the 

test button. When pushing the button previous errors will be “reset” and the battery will 

supply the LED’s. After 5 seconds an eventual error will be displayed. The test schedule 

can be reset by pushing the test button for 10 seconds. For more detailed information on 

the different testing schedule and meaning of the indications, see further in this 

instruction leaflet.

LUMINAIRES POWERED FROM CENTRAL BATTERY SYSTEMS

These luminaires are not equipped with their own integrated testing function. They are 

tested by means of the central battery system to which the luminaire is connected.

CT-NAVEO-LUMINARES

Central test luminaires (CT-Naveo / CIS) are supplied under a separate part code and are 

fitted with a test system PCB (COM-Box).

SLAVE LUMINAIRES WITH LTC

Slave type luminares for Emex / Sentara central emergency power systems are supplied 

under a separate part code and are fitted with an LTC PCB (COM-Box).

BATTERY

A fault will occur when test results for duration no longer meets the 

requirements indicated for the luminaire. The batteries must then be replaced. 

Please see the label on the batteries for the type required. Given the technical 

life of the battery, it is recommended to replace them after 4 years. When the 

battery is replaced and the mains supply restored, the amber LED indicating 

a battery failure will disappear after a successful duration test. Used batteries 

must be replaced or disposed of as household chemical waste.

PLEASE NOTE!

Constant voltage is required and the batteries must be sufficiently charged for emergency 

lighting to function properly. Failure to observe this requirement can damage the 

batteries, the lightsource or in worst-case scenario, the luminaires electronics.

INSPECTION AND MAINTENANCE

Emergi-lite strongly advises annual inspection of your emergency lighting installation.

®

ABB Emergi-Lite Ltd

Bruntcliffe Lane

Morley, Leeds

West Yorkshire LS27 9LL

United Kingdom

Sales  +44 (0) 333 999 9900

Tec44 (0) 113 281 0600

Email:  [email protected]

www.emergi-lite.co.uk

ABB United Arab Emirates

P.O. Box 11070

Dubai, 

United Arab Emirates

Tel: +971 (4) 3147500

Fax: +971 (4) 3401541

E-mail: [email protected]

www.abb.com/lowvoltage

EN 60598-1, EN 60598-2.22, VDE 0711, IEC 62034, EN 62386-202

EN 60598-1, EN 60598-2.22, VDE 0711, IEC 62034, EN 62386-202

KM 655958

DALI LUMINAIRES

Self-Contained luminaires fitted with a DALI communication module are supplied 

under a separate article number and have a configurable autotest (not equal to self test).

SURFACE MOUNTED LUMINAIRES