ZyAIR B-3000 Intelligent Wireless LAN Access Point
29
8 Troubleshooting
PROBLEM CORRECTIVE
ACTION
The
PWR
LED is
off.
Make sure you are using the correct power adaptor and the power adaptor is
plugged into an appropriate power supply.
Unplug the power adaptor and plug it in again. If the error persists, you may have a
hardware problem. In this case, you should contact your vendor.
The
ETHN
LED is
off.
Check the cable connection to the ZyAIR
ETHERNET
port.
Make sure your computer’s network card is working properly.
I cannot access
the web
configurator.
Make sure the IP addresses and subnet masks of the ZyAIR and the computer are
in the same IP address range. (For example, if the ZyAIR is using the default IP
address and subnet mask, check that the IP address of the computer is in the range
192.168.1.3 ~192.168.1.254 and the subnet mask is 255.255.255.0). Refer to the
Setting Up Your Computer’s IP Address
section.
If you changed the ZyAIR default IP address, then enter the new IP address as the
web site address.
The default password is “1234”. If you have changed the password and have now
forgotten it, you will need to reset the ZyAIR. Refer to the
User’s Guide
for how to
use the
RESET
button.
I cannot ping any
computer on the
wireless LAN.
If the
ETHN
LED is off, check the cables between the ZyAIR and your computer or
hub.
Verify that the IP address and the subnet mask of the ZyAIR and the computers are
in the same range.