background image

 

Default Login Details

User’s Guide

XGS1210-12 / XGS1250-12

 

Copyright © 2020 Zyxel Communications Corporation

Management IP Address

http://192.168.1.3

Password

1234

Version 1.00 Edition 1, 10/2020

Summary of Contents for XGS1210-12

Page 1: ...Default Login Details User s Guide XGS1210 12 XGS1250 12 Copyright 2020 Zyxel Communications Corporation Management IP Address http 192 168 1 3 Password 1234 Version 1 00 Edition 1 10 2020 ...

Page 2: ... product due to differences in your product firmware or your computer operating system Every effort has been made to ensure that the information in this manual is accurate Related Documentation Quick Start Guide The Quick Start Guide shows how to connect the Switch and access the Web Configurator More Information Go to support zyxel com to find other information on the Switch ...

Page 3: ...GS1210 12 and XGS1250 12 may be referred to as the Switch in this guide Product labels screen names field labels and field choices are all in bold font A right angle bracket within a screen name denotes a mouse click For example QoS Port Based QoS means you first click QoS in the navigation panel then the Port Based QoS sub menu to get to that screen Icons Used in Figures Figures in this user guid...

Page 4: ...s Guide 8 Getting to Know Your Switch 9 Hardware Installation 14 Hardware Panels 17 Web Configurator 21 Initial Setup Example 30 Tutorials 33 Technical Reference 37 System 38 Port 41 VLAN 45 Link Aggregation 48 Mirroring 50 QoS 52 IGMP Snooping 56 Management 59 Troubleshooting 65 ...

Page 5: ... Application 11 1 2 3 Bridging Application 11 1 2 4 VLAN Application Example 12 1 3 Way to Manage the Switch 12 1 4 Good Habits for Managing the Switch 12 Chapter 2 Hardware Installation 14 2 1 Installation Scenarios 14 2 2 Safety Precautions 14 2 2 1 Freestanding Installation Procedure 14 2 2 2 Wall Mounting 15 Chapter 3 Hardware Panels 17 3 1 Hardware Overview 17 3 2 Front Panel 17 3 3 Rear Pane...

Page 6: ...ing Out of the Web Configurator 29 Chapter 5 Initial Setup Example 30 5 1 Overview 30 5 1 1 Change the IP Address 30 5 1 2 Change the Password 31 Chapter 6 Tutorials 33 6 1 Overview 33 6 2 Creating a VLAN 33 6 3 Setting Port VID 35 Part II Technical Reference 37 Chapter 7 System 38 7 1 Overview 38 7 2 System Settings 38 Chapter 8 Port 41 8 1 Overview 41 8 1 1 What You Need to Know 41 8 2 Port Sett...

Page 7: ...S 52 12 2 3 Weighted Round Robin Scheduling WRR 53 12 3 Port Based QoS 53 12 4 IEEE 802 1p QoS 54 Chapter 13 IGMP Snooping 56 13 1 Overview 56 13 2 IGMP Snooping Settings 56 Chapter 14 Management 59 14 1 Overview 59 14 1 1 What You Need to Know 59 14 2 Management Settings 60 14 2 1 Firmware Upgrade 63 Chapter 15 Troubleshooting 65 15 1 Power Hardware Connections and LEDs 65 15 2 Switch Access and ...

Page 8: ...8 PART I User s Guide ...

Page 9: ... FEATURE MODEL XGS1210 12 XGS1250 12 VLAN Virtual Local Area Network YES YES QoS Quality of Service YES YES Switch Management YES YES Link Aggregation YES YES Port Mirroring YES YES IGMP Snooping YES YES IEEE 802 3az Energy Efficient Ethernet Standard YES YES Management VLAN NO YES HTTP or HTTPS enable NO YES Save configuration YES YES Upload stored device configuration file YES YES 10 Gbps SFP in...

Page 10: ...thernet cables to achieve 10 Gbps speeds Figure 1 Multi Gigabit Application XGS1210 12 Figure 2 Multi Gigabit Application XGS1250 12 See the following table for the cables required and distance limitation to attain the corresponding speed Table 2 Cable Types CABLE PORT TRANSMISSION SPEED MAXIMUM DISTANCE BANDWIDTH CAPACITY Category 5 1 11 100 Mbps 100 m 100 MHz Category 5e 1 11 1 Gbps 2 5 Gbps 5 G...

Page 11: ... s port or connect other switches to the Switch In this example all computers can share high speed applications on the server To expand the network simply add more networking devices such as switches routers computers print servers and so on Figure 3 Backbone Application 1 2 3 Bridging Application In this example the Switch connects different company departments RD and Sales to the corporate backb...

Page 12: ...dding moving or changing ports without any re cabling Shared resources such as a server can be used by all ports in the same VLAN as the server In the following figure only ports that need access to the server need to be part of VLAN1 Ports can belong to other VLAN groups too Figure 5 Shared Server Using VLAN Example 1 3 Way to Manage the Switch Use the Web Configurator to manage the Switch This a...

Page 13: ...estoring an earlier working configuration may be useful if the device becomes unstable or even crashes If you forget your password you will have to reset the Switch to its factory default settings If you backed up an earlier configuration file you would not have to totally re configure the Switch You could simply restore your last configuration ...

Page 14: ... This is especially crucial when your Switch does not have fans Overheating could affect the performance of your Switch or even damage it The surface of the Switch could be hot when it is functioning Do NOT put your hands on it You may get burned This could happen especially when you are using a fanless Switch The Switches with fans are not suitable for use in locations where children are likely t...

Page 15: ...ugh for the screws to slide into the wall mount holes and the power cord to run down the back of the Switch Note Make sure the screws are securely fixed to the wall and strong enough to hold the weight of the Switch with the connection cables 4 Place the Switch so the wall mount holes line up with the screws Slide the Switch down gently to fix it into place Wall mount the Switch with the Ethernet ...

Page 16: ...Chapter 2 Hardware Installation XGS1210 12 XGS1250 12 User s Guide 16 Figure 8 Screw Specifications XGS1210 12 Figure 9 Screw Specifications XGS1250 12 ...

Page 17: ... 3 2 Front Panel The following figure shows the front panel of the Switch Figure 10 Front Panel XGS1210 12 Figure 11 Front Panel XGS1250 12 3 3 Rear Panel The following figure shows the rear panel of the Switch Figure 12 Rear Panel XGS1210 12 Table 4 Port Comparison Table MODELS XGS1210 12 XGS1250 12 10 100 1000 Mbps Ethernet Ports 8 8 100 1000 Mbps 2 5 Gbps Ethernet Ports 2 100 1000 Mbps 2 5 5 10...

Page 18: ...le on the rear panel Connect the other end of the supplied power cord to a power outlet Make sure that no objects obstruct the airflow 3 3 2 Smart Fan for XGS1250 12 A properly functioning fan is essential along with a sufficiently ventilated and cool operating environment to prevent the Switch from overheating With Smart Fan the fan in the Switch automatically adjust its speed according to the in...

Page 19: ...On The port has a successful 1000 Mbps connection Blinking The Switch is transmitting data through the port Amber On The port has a successful 100 Mbps connection Blinking The Switch is transmitting data through the port Off The port is disconnected or disabled Port 11 Left LED Port 12 Right LED Blue On The port has a successful 10 Gbps connection Blinking The Switch is transmitting data through t...

Page 20: ...rough the port Green On The port has a successful 1000 Mbps connection Blinking The Switch is transmitting data through the port Amber On The port has a successful 100 Mbps connection Blinking The Switch is transmitting data through the port Off The port is disconnected or disabled Port 12 Right LED Blue On The port has a successful 10 Gbps connection Blinking The Switch is transmitting data throu...

Page 21: ...p windows from your device JavaScript enabled by default Java permissions enabled by default 4 2 System Login 1 Start your web browser 2 Type http and the IP address of the Switch for example the default management IP address is 192 168 1 3 in the Location or Address field Press ENTER Your computer must be in the same subnet in order to access this website address 3 The login screen appears The de...

Page 22: ...ocation system and model name in the same broadcast domain The information is then displayed in the ZON Utility screen and you can perform tasks like basic configuration of the devices and batch firmware upgrade in it You can download the ZON Utility at www zyxel com and install it in a computer Windows operating system 4 3 1 Requirements Before installing the ZON Utility in your computer please m...

Page 23: ...ersion support the ZON Utility Click the OK button to close this screen Figure 16 Supported Devices and Versions If you want to check the supported models and firmware versions later you can click the Show information about ZON icon in the upper right hand corner of the screen Then select the Supported model and firmware version link If your device is not listed here see the device release notes f...

Page 24: ... Utility Screen 3 Select a network adapter to which your supported devices are connected Figure 18 Network Adapter 4 Click the Go button for the ZON Utility to discover all supported devices in your network Figure 19 Discovery 5 The ZON Utility screen shows the devices discovered ...

Page 25: ...s 2 Renew IP Address Update a DHCP assigned dynamic IP address 3 Reboot Device Use this icon to restart the selected devices This may be useful when troubleshooting or upgrading new firmware 4 Reset Configuration to Default Use this icon to reload the factory default configuration file This means that you will lose all previous configurations 5 Locator LED Use this icon to locate the selected devi...

Page 26: ...uage Table 8 ZON Utility Fields LABEL DESCRIPTION Type This field displays an icon of the kind of device discovered Model This field displays the model name of the discovered device Firmware Version This field displays the firmware version of the discovered device MAC Address This field displays the MAC address of the discovered device IP Address This field displays the IP address of an internal i...

Page 27: ... 4 Web Configurator XGS1210 12 XGS1250 12 User s Guide 27 Figure 22 Web Configurator Layout A Click the menu items to open the screen in the main window B Click this link to log out of the Web Configurator A B ...

Page 28: ...Q VLAN for the Switch Link Aggregation This link takes you to screens where you can logically aggregate physical links to form one logical and higher bandwidth link Mirroring This link takes you to a screen where you can copy traffic from one port or ports to another port so that you can examine the traffic from the first port without interference QoS This link takes you to a screen where you can ...

Page 29: ...s This means that you will lose all configurations that you had previously and the password will be reset to 1234 IP address will also be reset to 192 168 1 3 1 Make sure the PWR SYS LED is on not blinking 2 To set the device back to the factory default settings press the RESET button for more than 6 seconds or until the PWR SYS LED begins to blink and then release it When the PWR SYS LED begins t...

Page 30: ...nt DHCP client field is Disable assign an IP address for the Switch The IP address makes it accessible from an outside network It is used by the Switch to communicate with other devices in other networks In this example you want to change the IP address to 192 168 1 5 1 Click Management in the navigation panel to open the following screen Figure 24 Change the IP Address 2 Enter the new IP address ...

Page 31: ...figurator you will be asked to change the default password 1234 If you wish to change the password again perform the following steps 1 Click Management in the navigation panel to open the following screen Figure 26 Change the Password 2 Enter the existing password in the Old Password field 3 Enter the new system password in the New Password field using the keyboard characters a z A Z 0 9 and _ The...

Page 32: ...up Example XGS1210 12 XGS1250 12 User s Guide 32 5 Click Apply You will automatically be logged out of the Web Configurator 6 A Log in screen appears Enter the new password and click SIGN IN to log in using the new password ...

Page 33: ...ts on the Switch are in VLAN 1 VLANs confine broadcast frames to the VLAN group in which the ports belongs You can create a VLAN group with fixed port members to do this If you want to have a port for example port 1 belong to another VLAN as well say VLAN 2 you need to create a VLAN first and then add the port to the VLAN Figure 27 Initial Setup Network Example VLAN 1 Click VLAN in the navigation ...

Page 34: ...a permanent member of the VLAN To ensure that VLAN unaware devices such as computers and hubs can receive frames properly click the port s box color to green to set the Switch to remove VLAN tags before sending Clicking the port s check box loops between untagging non member and tagging 4 Change the box color of other ports not a member of the VLAN group to gray 5 Click Apply to save the settings ...

Page 35: ...mes are forwarded to the VLAN group that the tag defines In the example network configure 2 as the port VID on port 1 so that any untagged frames received on that port get sent to VLAN 2 Figure 28 Initial Setup Network Example Port VID 1 Click VLAN in the navigation panel 2 Enter 2 in the PVID field for port 2 and click Apply to save your changes back to the Switch ...

Page 36: ...Chapter 6 Tutorials XGS1210 12 XGS1250 12 User s Guide 36 ...

Page 37: ...37 PART II Technical Reference ...

Page 38: ...ter describes the screens for system status and port details 7 2 System Settings The System screen displays when you log into the Switch or click System at the top of the Web Configurator The System screen displays the Switch s general device information and the port statistics ...

Page 39: ...1210 12 XGS1250 12 User s Guide 39 Figure 29 System The following table describes the labels in this screen Table 10 System LABEL DESCRIPTION System Information Model Name This field displays the model name of this Switch ...

Page 40: ...ber portion of an IP address The factory default subnet mask is 255 255 255 0 This field displays the Switch s subnet mask Gateway The field displays the gateway that allows you to send or receive data traffic to or from a different network than the one the Switch is on Per Port Status Port This identifies the Ethernet port on the Switch Link status This field displays the current status or speed ...

Page 41: ...switches connected together If this happens broadcasts are continually rebroadcast and could flood the network You must break the loop by stopping multiple paths between two switch ports Figure 30 The Switch has Two Ports Connected with the Same Cable Figure 31 The Connected Switch has Two Ports Connected with the Same Cable Figure 32 Two Connections between Switches Without Using the Spanning Tre...

Page 42: ...s reached per second the subsequent packets are discarded Enable this feature to reduce broadcast packets in your network You can specify limits on each port 8 2 Port Settings Click Port in the navigation panel to open the following screen See Section 1 2 1 on page 10 for information on Multi Gigabit Figure 33 Port ...

Page 43: ...isable to disable it Speed Type Select the speed of the Ethernet connection on this port The choices for XGS1210 12 are Auto for all ports 10 Mbps for ports 1 8 100 Mbps for ports 1 10 1000 Mbps for all ports 2 5 G for ports 9 10 DAC for ports 11 12 when using the DAC Direct Attach Copper cable SFP 1000M for ports 11 12 SFP 10G for ports 11 12 The choices for XGS1250 12 are Auto for all ports 10 M...

Page 44: ...low control in half duplex mode IEEE802 3x flow control is used in full duplex mode to send a pause signal to the sending port causing it to temporarily stop sending signals when the receiving port memory buffers fill Back pressure flow control is typically used in half duplex mode to send a collision signal to the sending port mimicking a state of packet collision causing the sending port to temp...

Page 45: ...rt The remaining 12 bits define the VLAN ID giving a possible maximum number of 4 096 VLANs Note that user priority and VLAN ID are independent of each other A frame with VID VLAN Identifier of null 0 is called a priority frame meaning that only the priority level is significant and the default VID of the ingress port is given as the VID of the frame Of the 4096 possible VIDs a VID of 0 is used to...

Page 46: ...roups In case this happens reset the Switch to the default settings see Section 4 5 on page 29 for more information Figure 34 VLAN The following table describes the labels in this screen Table 12 VLAN LABEL DESCRIPTION PVID Port This field displays the port number PVID A PVID Port VLAN ID is a tag that adds to incoming untagged frames received on a port so that the frames are forwarded to the VLAN...

Page 47: ... port is green and ports not participating in a VLAN are gray Multiple ports in a VLAN can be configured as tagged or untagged or not participating A port is a tagged port when the interface is expecting frames containing VLAN tags An example of this is when two switches are connected and pass tagged traffic Modify Click Modify to edit the VLAN settings Delete Click Delete to remove the VLAN group...

Page 48: ... bandwidth link Link aggregation is the grouping of physical ports into one logical higher capacity link You may want to trunk ports if for example it is cheaper to use multiple lower speed links than to under utilize a high speed but more costly single port link 10 2 Link Aggregation Use this screen to configure static link aggregation Figure 35 Link Aggregation XGS1210 12 ...

Page 49: ...ute traffic based on the packet s destination MAC address Select MAC SA DA to distribute traffic based on a combination of the packet s source and destination MAC addresses Link Aggregation Group The field identifies the default link aggregation groups the Switch supports Select which link aggregation group supports your choice in the previous field Link Aggregation Algorithm For example enabling ...

Page 50: ...s you to copy a traffic flow to a monitor port the port you copy the traffic to to examine the traffic from the monitor port without interference 11 2 Mirroring Settings Use this screen to select a monitor port and specify the traffic flow to be copied to the monitor port Note A port cannot be the monitor port and the mirrored port at the same time ...

Page 51: ...ection of the traffic to mirror by selecting from the drop down list box Choices are Egress outgoing Ingress incoming and Both Port This displays the port number Monitor Port The monitor port is the port you copy the traffic to in order to examine it in more detail without interfering with the traffic flow on the original ports Note Select one monitor port Mirrored Port Select this option to mirro...

Page 52: ...me sensitive applications include both those that require a low level of latency delay and a low level of jitter variations in delay such as Voice over IP VoIP or Internet gaming and those for which jitter alone is a problem such as Internet radio or streaming video 12 2 What You Need to Know The Switch can put packets into the queues according to the port on which the packet is received or the pr...

Page 53: ...r priority and queue weight the number you select in the queue Weight field rather than a fixed amount of bandwidth WRR is activated only when a port has more traffic than it can handle The bandwidth is divided across the different traffic queues according to their weights Queues with larger weights get more service than queues with smaller weights This queuing mechanism is highly efficient in tha...

Page 54: ...by PCP priority tags Table 16 QoS Port Based QoS LABEL DESCRIPTION Port Based QoS Port 1 12 Select which ports will carry the sensitive data using the priority queuing levels given Click on each port s radio button to assign a priority queue Weight Assign the weight the number you select in the queue Weight field to each priority Remember the weight is based on WRR Scheduling explained in Section ...

Page 55: ...02 1p QoS Priority 0 7 Select which priority tags will carry the sensitive data using the priority queuing levels given Click each priority tag s radio button to assign a priority queue Weight Assign the weight the number you select in the queue Weight field to each priority Remember the weight is based on WRR Scheduling explained in Section 12 2 3 on page 53 Bandwidth is divided across the differ...

Page 56: ... Router Port is set to Auto by default The port can be used as an IGMP router port IGMP Snooping The Switch can passively snoop on IGMP packets transferred between IP multicast routers or switches and IP multicast hosts to learn the IP multicast group membership It checks the IGMP packets passing through it picks out the group registration information and configures multicasting accordingly IGMP s...

Page 57: ...n this screen Table 18 IGMP Snooping LABEL DESCRIPTION IGMP Snooping Enable IGMP Snooping Select this option to enable IGMP Snooping to forward group multicast traffic only to ports that are members of that group Unknown Multicast Drop Select this option to discard the frame when the Switch receives an unknown multicast frame Otherwise the Switch sends the frame to all ports ...

Page 58: ...ving an IGMP query The Switch treats an IGMP query port as being connected to an IGMP multicast router or server The Switch forwards IGMP join or leave packets to an IGMP router port Note If link aggregation is enabled the ports in a link aggregation group will not be available in this field Apply Click Apply to save your changes to the Switch Table 18 IGMP Snooping continued LABEL DESCRIPTION ...

Page 59: ...eb protocol that encrypts and decrypts web pages Secure Socket Layer SSL is an application level protocol that enables secure transactions of data by ensuring confidentiality an unauthorized party cannot read the transferred data authentication one party can identify the other party and data integrity you know if data has been changed It relies upon certificates public keys and private keys HTTPS ...

Page 60: ...n then the Switch blocks all HTTP connection attempts 14 2 Management Settings An administrator is someone who can both view and configure Switch changes The default administrator password is 1234 Note It is highly recommended that you change the default administrator password 1234 Click Management in the navigation panel to open the following screen ...

Page 61: ...Chapter 14 Management XGS1210 12 XGS1250 12 User s Guide 61 Figure 44 Switch Management XGS1210 12 ...

Page 62: ...e Setting Reset Click this button to clear all Switch configuration information you configured and return to the factory defaults If you want to access the Switch Web Configurator again you may need to change the IP address of your computer to be in the same subnet as that of the default Switch IP address 192 168 1 3 Reboot Click this button to restart the Switch without physically turning the pow...

Page 63: ...168 1 254 Apply Click this button to save your changes to the Switch HTTPS HTTP XGS1250 12 only Select Enable to allow for HTTP or HTTPS services that may be used for managing the Switch from the specified trusted computers Otherwise select Disable Management VID XGS1250 12 only This is the ID number of the management VLAN Enter a number between 1 and 4094 as the management VLAN ID IEEE 802 3az EE...

Page 64: ...ystem crashes on the Switch Figure 46 Firmware Upgrade Path Type the path and file name of the firmware file you wish to upload to the Switch in the text box or click Path to locate it After you select the firmware file click the Upgrade button to load the new firmware Figure 47 Firmware Upgrade Confirmation Figure 48 Firmware Uploading After a successful upload the system will reboot and you will...

Page 65: ...adapter or cord is connected to the Switch and plugged in to an appropriate power source Make sure the power source is turned on 3 Disconnect and re connect the power adapter or cord to the Switch 4 If the problem continues contact the vendor One of the LEDs does not behave as expected 1 Make sure you understand the normal behavior of the LED See Section 3 4 on page 19 2 Check the hardware connect...

Page 66: ...device to its factory defaults See Section 4 5 on page 29 I cannot see or access the Login screen in the Web Configurator 1 Make sure you are using the correct IP address The default IP address is 192 168 1 3 If you changed the IP address use the new IP address If you changed the IP address and have forgotten it see the troubleshooting suggestions for I forgot the IP address for the Switch 2 Check...

Page 67: ... the following should happen during the firmware upgrade process a failure may occur During the firmware upgrade process The Switch loses power The computer from where you upload the firmware file to the Switch is turned off The Ethernet cable connecting the Switch and the computer comes loose This is the computer from where you uploaded the firmware file to the Switch When any of the above occurs...

Page 68: ...mation Please have the following information ready when you contact an office Required Information Product model and serial number Warranty Information Date that you received your device Brief description of the problem and the steps you took to solve it Corporate Headquarters Worldwide Taiwan Zyxel Communications Corporation http www zyxel com Asia China Zyxel Communications Shanghai Corp Zyxel C...

Page 69: ... Philippines Zyxel Philippines http www zyxel com ph Singapore Zyxel Singapore Pte Ltd http www zyxel com sg Taiwan Zyxel Communications Corporation https www zyxel com tw zh Thailand Zyxel Thailand Co Ltd https www zyxel com th th Vietnam Zyxel Communications Corporation Vietnam Office https www zyxel com vn vi Europe Belarus Zyxel BY https www zyxel by Belgium Zyxel Communications B V https www ...

Page 70: ...s Denmark Zyxel Communications A S https www zyxel com dk da Estonia Zyxel Estonia https www zyxel com ee et Finland Zyxel Communications https www zyxel com fi fi France Zyxel France https www zyxel fr Germany Zyxel Deutschland GmbH https www zyxel com de de Hungary Zyxel Hungary SEE https www zyxel com hu hu Italy Zyxel Communications Italy https www zyxel com it it Latvia Zyxel Latvia https www...

Page 71: ... Poland Zyxel Communications Poland https www zyxel com pl pl Romania Zyxel Romania https www zyxel com ro ro Russia Zyxel Russia https www zyxel com ru ru Slovakia Zyxel Communications Czech s r o organizacna zlozka https www zyxel com sk sk Spain Zyxel Communications ES Ltd https www zyxel com es es Sweden Zyxel Communications https www zyxel com se sv Switzerland Studerus AG https www zyxel ch ...

Page 72: ...h America Argentina Zyxel Communications Corporation https www zyxel com co es Brazil Zyxel Communications Brasil Ltda https www zyxel com br pt Colombia Zyxel Communications Corporation https www zyxel com co es Ecuador Zyxel Communications Corporation https www zyxel com co es South America Zyxel Communications Corporation https www zyxel com co es Middle East Israel Zyxel Communications Corpora...

Page 73: ...Communications Corporation https www zyxel com me en North America USA Zyxel Communications Inc North America Headquarters https www zyxel com us en Oceania Australia Zyxel Communications Corporation https www zyxel com au en Africa South Africa Nology Pty Ltd https www zyxel com za en ...

Page 74: ...ration is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the device This product has been tested and complies wit...

Page 75: ...emote risk of electric shock from lightning CAUTION Risk of explosion if battery is replaced by an incorrect type dispose of used batteries according to the instruction Dispose them at the applicable collection point for the recycling of electrical and electronic devices For detailed information about recycling of this product please contact your local city office your household waste disposal ser...

Page 76: ...ise au rebut la collecte séparée de votre produit et ou de sa batterie aidera à économiser les ressources naturelles et protéger l environnement et la santé humaine Il simbolo sotto significa che secondo i regolamenti locali il vostro prodotto e o batteria deve essere smaltito separatamente dai rifiuti domestici Quando questo prodotto raggiunge la fine della vita di servizio portarlo a una stazion...

Page 77: ...mplied including any implied warranty of merchantability or fitness for a particular use or purpose Zyxel shall in no event be held liable for indirect or consequential damages of any kind to the purchaser To obtain the services of this warranty contact your vendor You may also refer to the warranty policy for the region in which you bought the device at http www zyxel com web support_warranty_inf...

Page 78: ...ast frame 45 broadcast packets 41 broadcast storm control 41 button RESET 29 C cable types 10 CAT 5 cable 10 CAT 5e cable 10 CAT 6 cable 10 CAT 6a cable 10 CAT 7 cable 10 Certificate Authority CA 59 certifications 75 viewing 77 CFI Canonical Format Indicator 45 changing the password 28 clear counters 40 clearance Switch installation 14 collision signal 44 contact information customer support 68 co...

Page 79: ...eys 59 HTTPS introduction 59 HTTPS service enable 63 I icon logout 29 IEEE 9 IEEE 802 1p QoS apply 55 IEEE 802 1Q VLAN 52 add ports 33 maximum number 47 IEEE 802 3az EEE enable 63 IEEE 802 3az Energy Efficient Ethernet EEE 59 IEEE priority 53 IEEE802 3x flow control 44 IGMP Internet Group Management Protocol 56 IGMP join packet 58 IGMP leave packet 58 IGMP query port 58 IGMP snooping 56 overview 5...

Page 80: ... 41 loop prevention 41 LED 19 loop state 40 loop status 40 Low Power Idle LPI mode 59 lower speed link 48 M MAC address 40 Management screen 30 31 60 Management settings 60 management VLAN enable 63 managing the Switch good habits 12 maximum distance cable types 10 mirrored port 50 51 model name 39 monitor port 50 51 mounting wall 15 mounting holes distance 15 multicast 56 multicast drop 57 multic...

Page 81: ... information 76 registration product 77 RESET button 29 reset the Switch 62 resetting 29 restart the Switch 62 restoring configuration 29 rubber feet attach 14 S safety warnings 75 screen resolution recommended 21 screw specifications wall mount 16 single port link 48 Spanning Tree Protocol STP 41 SSL Secure Socket Layer 59 status 26 subnet mask 40 63 Switch fanless type usage precaution 14 fan ty...

Page 82: ...r home 26 inactivity timeout 22 layout 26 log out link 27 login 21 logout 29 main window 27 overview 21 Weighted Round Robin Scheduling WRR 53 Windows OS version check 22 WRR application example 53 WRR scheduling 54 WS web server 59 Z ZDP 22 ZON Utility 22 compatible OS 22 fields description 26 icon description 25 installation requirements 22 introduction 22 minimum hardware requirements 22 networ...