
Chapter 17 Diagnostic
VMG4005-B50A/B60A User’s Guide
62
The following table describes the labels in this screen.
17.6 OAM Ping
Click
Maintenance > Diagnostic > OAM Ping
to open the screen shown next. Use this screen to perform
an OAM (Operation, Administration and Maintenance) F4 or F5 loopback test on a PVC. The VMG sends
an OAM F4 or F5 packet to the DSLAM or ATM switch and then returns it to the VMG. The test result then
displays in the text box. ATM sets up virtual circuits over which end systems communicate. The
terminology for virtual circuits is as follows:
Figure 45
Virtual Circuit Topology
Table 26 Maintenance > Diagnostics > 802.3ah
LABEL
DESCRIPTION
IEEE 802.3ah Ethernet OAM
Click this switch to enable or disable the Ethernet OAM on the specified interface.
When the switch goes to the right
, the function is enabled. Otherwise, it is not.
Interface
Select the interface on which you want to enable the IEEE802.3ah.
OAM ID
Enter a positive integer to identify this node.
Auto Event
Click this switch to detect link status and send a notification when an error (such as
errors in symbol, frames, or seconds) is detected. Otherwise, disable this and you will
not be notified. When the switch goes to the right
, the function is enabled.
Otherwise, it is not.
Features
Select
Variable Retrieval
so the VMG can respond to requests for information, such
as requests for Ethernet counters and statistics, about link events.
Select
Link Events
so the VMG can interpret link events, such as link fault and dying
asp.Link events are set in event notification PDUs (Protocol Data Units), and indicate
when the number of errors in a certain given interval (time, number of frames,
number of symbols, or number of errored frame seconds) exceeds a specified
threshold. Organizations may create organization-specific link event TLVs as well.
Select
Remote Loopback
so the VMG can accept loopback control PDUs to convert
VMG into loopback mode.
Select
Active Mode
so the VMG initiates OAM discovery, send information PDUs; and
may send event notification PDUs, variable request/response PDUs, or loopback
control PDUs.
Apply
Click this button to save your changes.
• Virtual Channel (VC)
Logical connections between ATM devices
• Virtual Path (VP)
A bundle of virtual channels
• Virtual Circuits
A series of virtual paths between circuit end points
Summary of Contents for VMG4005-B50A
Page 8: ...8 PART I User s Guide ...
Page 22: ...22 PART II Technical Reference ...
Page 46: ...Chapter 13 Time Settings VMG4005 B50A B60A User s Guide 46 Figure 31 Maintenance Time ...
Page 57: ...Chapter 16 Backup Restore VMG4005 B50A B60A User s Guide 57 Figure 41 Maintenance Reboot ...