Note: These commands *Hn and *HS need supervisory password checking. Any character can
be entered in the password (0-255). Maximum password length is eight.
+
*I0
AT command set (Default).
*I1
V.25bis command set.
*I2
Dumb mode.
Note: Enter RST command in V.25bis mode will revert modem to asynchronous AT command
mode.
+
*L0
Panel key normal (Default).
*L1
Panel key locked.
+
*M0
Leased line auto-handshake on originate mode (Default).
*M1
Leased line auto-handshake on answer mode.
*P0-15 Set leased line transmission power level, range from 0 dBm to -15dBm (Default
= -9dBm). Range from -12dBm to -27dBm if S35 bit 3 is set.
*Q0
No response to poor signal quality.
*Q1
Retrain action taken if signal quality is poor.
+
*Q2
Adaptive rate; auto fall-back or fall-forward (Default).
*Q3
Disconnect for poor signal quality.
*Rab
Read remote profile b to local profile a.
a=
0-3,
local user profile number.
b=
0-3,
remote user profile number.
4,
remote active configuration.
5,
remote factory default.
Note: The command *Rab only works when modem is on-line, no matter what kind of connection.
+
*S0
Secondary channel disabled (Default).
*S1
Secondary channel enabled.
*T
Display last caller ID message.
*V
View password table.
Note: The command *V needs supervisory password checking.
*Wab
Write local configuration profile a to remote user profile b and reset remote modem
from that profile.
a=
0-3,
local user profile number.
4,
local active configuration.
5,
local factory default settings.
b=
0-3,
remote user profile number.
Note: The command *Wab only works when modem is on-line, no matter what kind of
connection.