background image

0x01, Alarm Level == 0x11) 

to the Module. The load or the lamp plugged into 

the On/Off Module SHD2110 or Lamp Module SHD2210 will flash for 10 
seconds. 

 
 

Advanced Operation 
 

The following information is for someone that has some experience setting up a 
Z-Wave system or someone that has computer software running a Z-Wave 
controller. 

 
Enabling/Disabling Power Saving Function (for testing) 

   
When no movement has been detected for 10 seconds, the SHD1112 will enter the 
power saving mode. It can be disabled or enabled power saving function by setting 
Configuration Parameter # 3. 
 
This parameter can be configured with the value of 0 through 127, where 0 means 
power saving being enabled and others mean power saving being disabled. 
 

Note:

    As  long  as  the  batteries  have  been  refitted,  the  Detector  will  enable  the 

power saving function automatically.   
 

Configuring the Phase Level of ON Command 

 
The  Configuration  parameter  that  can  be  used  to  adjust  the  phase  level  of  ON 
command  is  transmitted  is  Configuration  Parameter  #  1.  This  parameter  can  be 
configured with the value of 0 through 127. 
 
Value                0: Set Device OFF(0x00) 
Value          1-99: Set Device On (1-99) 
Value    100-127: Set Device On to the last phase (0xFF) 
 

Note: 

0xFF means  the  device  will  be  on  to  the last  phase  before  the  device  was 

turned off. 
 

Wakeup Command Class 
 

The  Motion  Detector  will  send  a  Wakeup  Notification  Command  if  it  has  been 
included  into  a  Z-Wave  network.  The  prerequisite  is  the  connected  Z-Wave 
controller needs to emit a node ID and wakeup time interval to the Detector.

 

 

The Motion Detector will wake up periodically as desired depending on time interval 
you  set  from  wake  up  command  class  and  resend  the  Wakeup  Notification 
Command unless configured for another time interval. The Motion Detector will stay 
awake for 10 seconds and then go back to sleep to conserve battery life. 
 
The time interval between Wakeup Notification Commands can be adjusted if you 
have a device in which that is supported. Refer to that device

’s instructions. 

 

Troubleshooting 

 

Symptom 

Possible Cause 

Recommendation 

Cannot carry out 
inclusion and association 

1.  Run out of battery 

power 

2.  Check if reverse 

battery polarity 

3.  Check if the detector 

is out of order 

1.  Replace a new 

battery 

2.  Refit the battery 

with correct polarity 

3.  Ensure the 

detector is 
working properly 

Cannot control the 
connected modules 

1.  Run out of battery 

power 

2.    Check if the detector 

is out of order 

1.  Replace a new 

battery 

2.  Ensure the 

detector is working 
properly 

The detector not working 

1.  Run out of battery 

power 

2.  Check if the mounting 

location is proper 

3.  Check if the detector 

is mounted above a 
radiator or heater 

4.  Check if the detector 

is out of order 

1.  Replace a new 

battery 

2.  Reposition its 

mounting location 

3.  Remove the 

source of 
interference or 
reposition its 
mounting location 

4.  Ensure the 

detector is working 
properly 

 
 
 
 
 
 