ZyXEL Communications SHD1111 Quick Start Manual Download Page 7

7

The SHD1111 goes to sleep mode again after 10 seconds. Press the 
tamper switch three times within 1.5 seconds to extend the 
awakened time to 10 minutes.

3.  

If the tamper switch is not pressed, the SHD1111 stays in testing 

mode. Detach the magnet from the SHD1111. The LED illuminates 
for 2 seconds to confirm that the SHD1111 and the magnet respond 
to each other properly. 

4.  

If the tamper switch is pressed, the SHD1111 enters normal mode 

and the LED does not illuminate when it is triggered to save battery 
power. It lights up only when the battery level is low.

Toubleshooting

Symptom

Possible Cause

Recommendation

Cannot establish 
inclusion and 
association

1. No battery power.
2.  Batteries might be 

inserted wrong. 

1. Replace with new batteries.
2.  Place batteries in correct 

position.

LED illuminating, 
but cannot control 
the connected 
modules

Inclusion and association 
not established.

Establish inclusion and 
association.

Frequency interference.

Retry after a few second.

Summary of Contents for SHD1111

Page 1: ...www zyxel com Quick Start Guide SHD1111 Door Window Detector Version 1 00 Edition 1 7 2011 2011 ZyXEL Communications Corporation C ...

Page 2: ...2 ...

Page 3: ...Batteries Follow the steps below to inserting batteries into the SHD1111 1 Remove the screw from the bottom of the SHD1111 2 Detach the back cover 3 Insert 3 AAA size 1 5V batteries into the battery compartment Note Alkaline batteries are highly recommended Note To replace the batteries remove the old ones and wait for 5 seconds before inserting the new batteries Adding to Z Wave Network The SHD11...

Page 4: ...ress the tamper switch 3 times within 1 5 seconds to enter inclusion mode Exclusion 1 Have the Z Wave Controller enter exclusion mode The LED is on whenever the tamper switch is pressed 2 Press the tamper switch 3 times within 1 5 seconds to enter exclusion mode Reset 1 Press the tamper switch 3 times within 1 5 seconds 2 Within 1 second press and hold the tamper switch until the LED is off The LE...

Page 5: ...SHD1111 to its back cover and secure it 4 Use adhesive tapes or 19mm fixing screws to affix the magnet to the moving part of the door window opposite of the SHD1111 Make sure the matching line on the magnet is aligned with the SHD1111 and at the right direction as shown in the figure below Association 1 Have the Z Wave Controller enter association mode 2 Press the tamper switch 3 times within 1 5 ...

Page 6: ...nstalled where security is required Note Be careful when affixing the SHD1111 to a metal frame or mounting within 1 meter of metalwork i e radiators water pipes etc as this could affect the radio range of the device If necessary you can space the magnet and SHD1111 away from the metal surface using a plastic or wooden spacer Operations 1 The SHD1111 allows 10 minutes for adding to a Z Wave network...

Page 7: ...amper switch is pressed the SHD1111 enters normal mode and the LED does not illuminate when it is triggered to save battery power It lights up only when the battery level is low Toubleshooting Symptom Possible Cause Recommendation Cannot establish inclusion and association 1 No battery power 2 Batteries might be inserted wrong 1 Replace with new batteries 2 Place batteries in correct position LED ...

Page 8: ...ctive RoHS 2002 95 EC Directive DEEE 2002 96 EC DEEE Déchets des Equipements Electriques et Electroniques 2008 34 EC Signature de la déclaration Nom Titre Raymond Huang Quality Customer Service Division Assistant VP Date aaaa mm jj 2011 1 24 ITALIANO NEDERLANDS SVENSKA Dichiarazione Green Product Direttiva RoHS 2002 95 CE Direttiva RAEE 2002 96 CE RAEE Rifiuti di Apparecchiature Elettriche ed Elet...

Reviews: