![ZyXEL Communications SHD1111 Quick Start Manual Download Page 7](http://html.mh-extra.com/html/zyxel-communications/shd1111/shd1111_quick-start-manual_945585007.webp)
7
The SHD1111 goes to sleep mode again after 10 seconds. Press the
tamper switch three times within 1.5 seconds to extend the
awakened time to 10 minutes.
3.
If the tamper switch is not pressed, the SHD1111 stays in testing
mode. Detach the magnet from the SHD1111. The LED illuminates
for 2 seconds to confirm that the SHD1111 and the magnet respond
to each other properly.
4.
If the tamper switch is pressed, the SHD1111 enters normal mode
and the LED does not illuminate when it is triggered to save battery
power. It lights up only when the battery level is low.
Toubleshooting
Symptom
Possible Cause
Recommendation
Cannot establish
inclusion and
association
1. No battery power.
2. Batteries might be
inserted wrong.
1. Replace with new batteries.
2. Place batteries in correct
position.
LED illuminating,
but cannot control
the connected
modules
Inclusion and association
not established.
Establish inclusion and
association.
Frequency interference.
Retry after a few second.