![ZyXEL Communications SHD1110 Quick Start Manual Download Page 8](http://html1.mh-extra.com/html/zyxel-communications/shd1110/shd1110_quick-start-manual_944676008.webp)
8
8
3.
Use the [
] and [
] buttons to adjust the degree of
temperature, and hold the [
] or [
] button to scan through
the temperature reading from -20
o
C to 50
o
C. Once the value is
selected, press [
] to confirm setting or press [
] to cancel.
4.
To clear the trigger-ON/OFF record, press both [
] and [
]
at the same time. The record is cleared after a long beep is sounded.
5.
If the temperature reaches the preset trigger-ON/OFF value, the
SHD1110 will send out RF signals. The screen returns to
Mode 1
and
the icon [
] or [
] is flashing with backlight illuminate and beep
tone sounds for 1 second. Press any key to stop the beep tone.
Note: The temperature trigger-ON and trigger-OFF cannot be the same; there
MUST be at least 2
o
C difference. For example, if the current trigger-OFF
temperature is set to 20
o
C, the trigger-ON temperature cannot be
between 18
o
C and 22
o
C.
Note: Once the SHD1110 has been triggered, the temperature must increase or
cool down at least 2
o
C from the preset value before it can be triggered
again. For example, if the SHD1110 is triggered on at 20
o
C, then the
temperature must be over 22
o
C or less than 18
o
C before it can be re-
triggered.
Humidity Settings
Displaying Current Humidity
1.
Press [
] and select
Mode 2
to display
current humidity.
2.
The humidity ranges from 20% RH to 90%RH
(+15% RH). To show the last record of max/
min humidity, press [
] or [
]. To
clear the record, press both [
] and [
] at the same time.
Note: If the humidity is reaching the limit, the
MAX
or
MIN
icon will be displayed
on the screen.
Mode 2