![ZyXEL Communications SHD1110 Quick Start Manual Download Page 10](http://html1.mh-extra.com/html/zyxel-communications/shd1110/shd1110_quick-start-manual_944676010.webp)
10
10
Radio Frequency Settings
You can enable or disable the sending of RF commands which
comprised of Z-Wave protocol to the associated nodes, as the SHD1110
has been triggered on/off.
1.
Press [
] and select
Mode 7
. The icon
[
] starts flashing.
2.
Press [
] to enable the RF function or
[
] to disable it.
Note: If the RF mode is
OFF
, no command will be sent even if the SHD1110 has
been triggered. If RF is
ON
and the SHD1110 has been triggered, the RF
command will be sent to nodes of Grouping 2 (see the User’s Guide for
more information on Z-Wave Grouping).
Note: If the RF reading is 00, it implies no node ID has been allocated by the Z-
Wave Controller. Please execute inclusion mode as described in the
section.
Beep Tone Settings
1.
To set the beep tone, press [
] and select
Mode 8
. The icon[
] flashes.
2.
Press [
] for
ON
and [
] for
OFF
. If
the beeper is
ON
, a beep tone will be sounded
whenever a button is pressed; 4 continuous
beep tones will be sounded if the SHD1110 has been triggered.
If the temperature falls to 0
o
C, temperature display will illuminate and
beep for 1 second. Press any key to stop the beep tone.
Mode 7
Mode 8