Omni 56K Smart User’s Guide
5-4
Command Sets
Table 5-2 AT Command Sets Requiring an "AT" Prefix
COMMAND
OPTIONS
FUNCTION & DESCRIPTION
REF.
Xn
n=0-7 5 *
Result code options, see Table 4 1.
S23.3-5
n=0-2
Resets the modem and set power-on profile.
S15.5-7
Zn
Resets the modem and load user profile n (0-1).
Zn
Z2
Resets the modem and load factory settings.
5.1.2 Extended AT& Command Sets
Table 5-3 Extended AT& Command Sets
COMMAND
OPTIONS
FUNCTION & DESCRIPTION
REF.
Data rate, terminal-to-modem. (DTE/DCE)
S28.6
&B0
The DTE rate follows the connection rate. (See
also S44.6)
&Bn
&B1 *
The DTE/DCE rates are fixed at the DTE setting
(See also S18, S20, and S44.6)
Carrier Detect (CD) options
S21.4
&C0
CD always ON (See also S42.7)
&Cn
&C1 *
CD tracks the presence of carrier (See also S38.3,
S42.7)
Data Terminal Ready (DTR) options. (See also
S25)
S21.6-7
&D0
Ignore DTR signal, assume DTR is always ON.
&Dn
&D1
108.1, DTR OFF-ON transition causes dialing of
the default number. (See also 'AT*Dn' and S48.4)
&D2 *
108.2, Data Terminal Ready, DTR OFF causes the
modem to hang up.
&D3
Same as &D2 but DTR OFF causes the modem to
hang up and reset from profile 0.
&F
Load factory settings to RAM as active
configuration.