Zynex Medical NexWave User Manual Download Page 4

4

 

 

Zynex Medical 

Contact Information

 

 

CUSTOMER SERVICE

 

800

-

495

-

6670

 

 

 

Supplies:

 

To order more electrodes or other  accessories

 

 

 

Technical Support:

 

Questions or problems with using your device

 

 

 

Device Return:

 

Order a postage paid return envelope to return 

   

your device at no charge

 

 
 

MAIN OFFICE

 

800

-

495

-

6670

 

 

 

 

 

Billing Questions:

 

Questions regarding insurance benefits and 

 

   

covered benefits for Durable Medical Equipment 

   

(DME) or questions about an Explanation of 

 

   

Benefits form you received in the mail

 

 

FAX NUMBER

 

800

-

495

-

6695

 

 

855

-

845

-

5941

 

 

MAILING ADDRESS

 

 

 

Zynex Medical, Inc.

 

 

9555 Maroon Circle

 

 

Englewood, CO 80112

 

 

USA

 

 

EMAIL

 

[email protected]

 

 

 

WEBSITE

 

www.zynex.com

 

 
 

 

45

 

 

NexWave 

Warranty Information

 

 

 

The NexWave device is warranted to be free from defects in material, workmanship, 
and structural integrity when subjected to normal domestic use and service for five 
years after the original purchase.

 

 

During that time, Zynex Medical, Inc. will replace, at its sole discretion, the NexWave 
device that has been used in a standard manner.  This warranty does not cover misuse 

or use contrary to the operating instructions supplied.

 

 

Warranty obligations are limited to replacement of defective parts and components, at 
the option of Zynex Medical, Inc.  This Warranty is only valid for the original purchaser 

of this product and will not be honored if the product ownership is transferred or is 
resold.

 

 

To obtain warranty service, please contact Technical Support at the number listed on 

page 4 of this manual.

 

 

 

Summary of Contents for NexWave

Page 1: ...48 P N 300400 Rev 13 0 Zynex Medical Inc 9555 Maroon Circle Englewood CO 80112 USA Phone 1 800 495 6670 Fax 1 800 495 6695 Internet www zynex com Email info zynex com NexWave User s Manual...

Page 2: ...2 47...

Page 3: ...ion 6 Electrodes and Lead Wires Setup 9 Programming Instructions 12 Preprogrammed Modes 13 Controls 15 Operating Instructions 16 Protocols 17 Indications Contraindications and Warnings 32 Precautions...

Page 4: ...ynex com 45 NexWave Warranty Information The NexWave device is warranted to be free from defects in material workmanship and structural integrity when subjected to normal domestic use and service for...

Page 5: ...leaning solutions directly onto the unit or immerse it in water or other liquids 5 About the NexWave The NexWave is a multiple mode stimulator which allows users a choice of treatment options This dev...

Page 6: ...of a flammable anesthetic mixture with air or in the presence of a flammable anesthetic mixture with oxygen or nitrous oxide 43 NexWave Specifications and Accessories Interferential Current IFC Amplit...

Page 7: ...t circuit the outputs If the electrode alarm ceases the problem is with the electrode connection integrity Troubleshooting When the ON button is pressed a flashing Lock icon appears on the display and...

Page 8: ...h suspected or diagnosed heart problems Caution should be used for patients with suspected or diagnosed epilepsy Caution should be used in the presence of the following 1 When there is a tendency to h...

Page 9: ...to high frequency surgical equipment may result in burns at the site of the stimulator electrodes and possible damage to the stimulator Operations within close proximity within one meter of shortwave...

Page 10: ...S voltage 500 load 6 48 V Maximum RMS current 500 load 12 96 mA Maximum output power 500 load 0 084 W per channel Maximum RMS voltage 1 K load 12 96 V Maximum RMS current 1 K load 12 96 mA Maximum out...

Page 11: ...utlet is easily accessible This device is capable of generating current densities for electrodes exceeding 2 mA rms cm2 which may require special attention of the operator Do not exceed 0 5 W cm2 with...

Page 12: ...hlebitis thrombophlebitis varicose veins etc Stimulation shall not be applied over or in proximity to cancerous lesions This device is capable of generating currents and voltages in excess of 10 mA RM...

Page 13: ...e laryngeal and pharyngeal muscles may occur and the contractions may be strong enough to close the airway or cause difficulty in breathing 13 NexWave Preprogrammed Modes Interferential Current IFC Mo...

Page 14: ...l electrical device does not incorporate a power switch to isolate the system from the AC mains Unplug the power cord of the AC adapter from the AC mains outlet in order to positively disconnect from...

Page 15: ...des and possible damage to the stimulator Operations within close proximity within one meter of shortwave or microwave therapy equipment may produce instability in the stimulation output Safety Refere...

Page 16: ...until Unlock button is pressed 33 NexWave Warnings Interferential Current IFC Warnings Continued Maximum peak output voltage 500 load 25 V Maximum peak output current 500 load 50 mA Maximum peak outpu...

Page 17: ...mum stimulation setting 50 mA 2 square Maximum stimulation setting 50 mA Output waveform power information When delivering stimulation energy the NexWave in IFC mode is a constant current output devic...

Page 18: ...channels and crisscrossing the electrodes is optional when using the TENS modality Lumbar Back 31 SPASM REDUCTION Muscle spasm may be reduced by intentionally fatiguing the associated muscle or muscle...

Page 19: ...Journal of Sports Medicine 13 16 20 2003 Lippincott Williams Wilkins Inc Philadelphia IFC Modality Place the electrodes with the RED and BLACK ends of the lead wires according to pattern depicted on...

Page 20: ...e to the left Using both channels and crisscrossing the electrodes is optional when using the TENS modality 29 PAIN CONTROL INTENSITY LEVEL The stimulation level should be set to a strong but comforta...

Page 21: ...ng the electrodes is optional when using the TENS modality ACHILLES TENDON ANKLE ACHILLES TENDON ANKLE 21 PAIN CONTROL INTENSITY LEVEL The stimulation level should be set to a strong but comfortable s...

Page 22: ...odality Palmar View same arm Dorsal View same arm Palmar View same arm Dorsal View same arm 27 PAIN CONTROL INTENSITY LEVEL The stimulation level should be set to a strong but comfortable strength DEV...

Page 23: ...rossing the electrodes is optional when using the TENS modality 23 PAIN CONTROL INTENSITY LEVEL The stimulation level should be set to a strong but comfortable strength DEVICE SET UP Modality Mode Tre...

Page 24: ...t Using both channels and crisscrossing the electrodes is optional when using the TENS modality 25 PAIN CONTROL INTENSITY LEVEL The stimulation level should be set to a strong but comfortable strength...

Reviews: