Figure 7-20 Door Sensors Connection
The ‘Door Opened Timeout’ parameter controls the maximum allowed time when door can be opens. Parameter can
be configured by using the WEB interface: Door Functions / Parameters screen (See Figure 7-15). Door Phone
initiates alarm call to pre-
configured Day or Night destination number if a ‘Door Opened Timeout’ parameter time
interval expired but door did no returns to its IDLE mode.
To activate Door Status Sensors:
Connect Door S
tatus sensors to appropriate IP Door Phone connector pins ‘Sensor 1’ / ‘ Sensor 2’
o
Note: Be sure that Sensors are ‘Normally Open’ type in IDLE mode when door is closed.
In IP Door phone WEB GUI interface:
o
Go to Door Functions / Sensor screen
o
In ‘Individual Settings’ region select ‘Status Sensor’ option for required Door 1 or Door 2
o
Go to Door Functions / Parameters and configure ‘Door Opened Timeout’
Call to Destination from the IP Door Phone
Open a door and leave door opened during time interval, wh
ich is longer than ‘Door Opened Timeout’
configured parameter value.
o
Note: Check the Sensor provides ‘Connection’ status via its pins when door is open.
IP Door Phone calls to Day/Night destination