b.

 

Remove all plastic and paper protections from each part of the microscope (eyepieces, 

light, diaphragm,…) 

c.

 

Familiarize  with  the  mechanical  components  of  the  microscope.  Move  these 

components to see how they behave and if they operate properly.  

d.

 

Insert the plug into the socket at the back of the microscope. Connect the other end to 

the  electrical power supply.  If the  batteries are  charged the microscope can be  used 

without connecting to the electrical power supply.  

Note:

  in  case  of  using  the  microscope  connected to the  power  supply,  it  should  be  properly 

earthed.  Make  sure  the  input  voltage  is  the  appropriate  for  this  equipment  (100-240V;  50-

60Hz).  

4.2 Using the instrument 

a.

 

Turn the power source of the microscope on by pressing the switch at the back of the 

microscope. The light intensity can be regulated by means of the knob placed at the 

left  side  of  the  base  of  the  microscope.  It  is  recommended  to  be  used  at  70%  of 

intensity.  

b.

 

Place the simple (microscope slide) and hold it with the clamp; to open the clamp use 

the metal lever at the left side.  

c.

 

The amplitude of the light beam that reaches the simple can be adjusted by changing 

the  diaphragm  aperture.  The  maximum  resolution  is  obtained  by  adjusting  properly 

this aperture. Every time the objective is changed and to get the best resolution it is 

advisable to remove the eyepiece to see the size of the diaphragm aperture through 

the eyepiece tube. The diaphragm aperture must be adjusted until it is a little smaller 

than the objective aperture.  

Note:

  The  diaphragm  aperture  does  not  change  light  intensity;  for  this  use  the  knob 

placed at the left side of the base of microscope.  

d.

 

If needed put the filter in the filter holder.  

e.

 

Start  observation  always  with  low  magnification  objectives  4x  and  10x.  To  avoid  the 

objective  touching  the  sample,  turn  the  coarse  focusing  knob  to  lift  the  mechanical 

stage  until  it  reaches  a  few  millimeters  from  the  objective.  The  turn  slowly  the  fine 

focusing knob to focus the image. 

f.

 

Once the image is well focused change to the next higher magnification objective and 

adjust  focus  by  turning  only  fine  focusing  knob.  To  change  the  objective  turn  the 

nosepiece  until hearing a “click” sound and make  sure it is well centered in the  light 

beam. Always try to change the objective by holding the nosepiece not the objective 

Summary of Contents for B-HB11

Page 1: ...o Le recomendamos leer atentamente el presente manual y seguir rigurosamente los procedimientos de uso para obtener las m ximas prestaciones y una mayor duraci n del mismo This manual should be availa...

Page 2: ...quipo 7 5 Mantenimiento 8 6 Causas de una mala imagen 9 7 Resoluci n de problemas 9 8 Recomendaciones pr cticas 10 9 Accesorios incluidos 11 English 12 1 Applications of the instrument 13 2 Descriptio...

Page 3: ...ientos Si esto ocurre desenchufe inmediatamente el equipo de la toma de corriente Cualquier duda puede ser aclarada por su distribuidor instalaci n puesta en marcha funcionamiento Nunca desmonte el eq...

Page 4: ...tos en la siguiente imagen Figura 1 Figura 1 Dependiendo del modelo el cabezal del microscopio puede ser monocular modelo M HB10 o binocular Modelo B HB11 El cabezal tipo Siedentopf est inclinado 30 y...

Page 5: ...ura 2 El microscopio dispone de mandos de enfoque micro maro coaxiales y en posici n ergon mica y est n equipados con anillo de ajuste de tensi n Figura 3 Figura 3 El microscopio dispone de bater as r...

Page 6: ...icro y macrom tricos Escala de enfoque 0 002mm ILUMINACI N LED 3W 4V intensidad regulable ALIMENTACI N 100 240V 50 60Hz Bater as recargables 3x NiMH AA1400mAH 1 2V Tabla de objetivos Tipo Aumentos Ape...

Page 7: ...cide sobre la muestra puede regularse mediante la apertura del diafragma La resoluci n m xima se obtiene ajustando correctamente dicha apertura Al cambiar de objetivo y para conseguir una mejor resolu...

Page 8: ...n deber ajustar la distancia interpupilar distancia entre los oculares para adaptarse a sus ojos Adem s deber enfocar la imagen en primer lugar y mediante los mandos macro y microm trico con uno de lo...

Page 9: ...en su conjunto Nunca debe desmontarse el cabezal pero si pueden limpiarse delicadamente soplando con una pera aquellas superficies accesibles de los prismas Girar el objetivo si las im genes par sitas...

Page 10: ...mente situado en la trayectoria del haz luminoso si no es as girarlo hasta que se inserte correctamente en su posici n Comprobar si la muestra se encuentra situada correctamente en la platina y aseg r...

Page 11: ...en ning n tipo de l quido dado que puede provocar el desprendimiento de la lente Dependiendo de las preferencias del observador se puede modificar la tensi n de los mandos de enfoque macrom trico para...

Page 12: ...In case it may happen unplug the equipment immediately If you have any doubt installation setting up operation please contact your distributor Never dismantle the different pieces of the microscope to...

Page 13: ...ents are shown in below image Figure 1 Figure 1 Depending on the model the head can be monocular Model M HB10 or binocular Model B HB11 The Siedentopf head is 30 inclined and 360 rotatable In the bino...

Page 14: ...s Figure 2 Figure 2 The coaxial fine and focusing knobs are at an ergonomic position and are equiped with a tension adjustment ring Figure 3 Figure 3 The microscope is provided with rechargeable batte...

Page 15: ...agm and filter FOCUS Coaxial coarse and fine focusing knobs focus scale 0 002mm LIGHT LED 3W 4V adjustable intensity POWER SUPPLY 100 240V 50 60Hz Rechargeable batteries 3x NiMH AA1400mAH 1 2V Objecti...

Page 16: ...left side c The amplitude of the light beam that reaches the simple can be adjusted by changing the diaphragm aperture The maximum resolution is obtained by adjusting properly this aperture Every time...

Page 17: ...s and then adjust the diopter correction of the other eyepiece until the image is also focused with this eyepiece 5 Maintenance a The microscope must be installed in a dry clean and free of acid and a...

Page 18: ...o remove the dust Watch the front part of the microscope with a magnifying glass or an inverted eyepiece Immersion oil is enough and does not contain air bubbles or impurities Thickness of slides cove...

Page 19: ...tive touches the prepared slide when focusing Check the prepared slide is not the other way round being the cover glass over the slide and place it properly in case it is appropriate to do so Check al...

Page 20: ...provoke the lens detachment Depending on the observer preferences the tension of the coarse adjustment knobs can be modified since it is provided with a tension adjustment ring that is located next to...

Reviews: