background image

ZUWA Impeller Pumps 

 

 
 

 

1.  Declaration of conformity 

 

Declaration of conformity according to EC Directives: 

 

98/37/EC (Machinery);  

 

89/336/EEC with subsequent amendments (Electromagnetic Compatibility);  

 

73/23/EEC amended by 93/68/EEC (Low Voltage);  

 

2000/14/EC (Noise Emissions for Outdoor Equipment) 

The manufacturer,  

ZUWA - Zumpe GmbH, 83410 Laufen, Germany, 

hereby declares that the pump models listed below for the decanting of non-flammable 
or explosive liquids comply with the provisions of the above-mentioned CE Directives.  

The following harmonised and national standards and technical specifications have 
been applied: 

EN 292-1-91 Safety of Machinery 

EN 292-2/A1-95 Safety of Machinery 

EN 294-92 Safety of Machinery 

EN 61000-6-1 Electromagnetic Compatibility 

EN 61000-6-3 Electromagnetic Compatibility 

EN 60034-1-1998 Rotating Electrical Machines 

EN 55014-1-00 (A1/01; A2/02) Electromagnetic Compatibility 

EN 55014-2-97 Electromagnetic Compatibility 

EN 60204-1-00 Safety of Machinery 

EN 60034-5-01 Rotating Electrical Machines 

EN 60335-2-41 Household and similar electrical appliances Safety: Particular 
requirements for pumps 

Pump model designations: 

UNISTAR 2000-A impeller pump 

UNISTAR 2000-B impeller pump 

COMBISTAR 2000-A impeller pump 

COMBISTAR 2000-B impeller pump 

NIROSTAR 2000-A impeller pump 

NIROSTAR 2000-B impeller pump 

Laufen, 21/07/2008 

 

Helmut Wimmer CEO 

Summary of Contents for COMBISTAR 2000-A

Page 1: ...UNISTAR COMBISTAR NIROSTAR Operating Instructions Flexible Impeller Pumps Zumpe GmbH Pumps and Sprayers...

Page 2: ...ZUWA Impeller Pumps 2...

Page 3: ...lectrical connection 10 5 3 1 Series 2000 A and 2000 B 10 5 3 2 Series 2001 A and 2001 B 11 6 Commissioning 12 7 Storage 13 8 Maintenance 14 8 1 Routine inspection 14 8 2 Disassembling the pump 14 8 2...

Page 4: ...ifications have been applied EN 292 1 91 Safety of Machinery EN 292 2 A1 95 Safety of Machinery EN 294 92 Safety of Machinery EN 61000 6 1 Electromagnetic Compatibility EN 61000 6 3 Electromagnetic Co...

Page 5: ...ISTAR 2001 A COMBISTAR 2000 B COMBISTAR 2001 B NIROSTAR 2000 A NIROSTAR 2001 A NIROSTAR 2000 B NIROSTAR 2001 B 2 1 Further applicable documents Parts list with exploded drawings Dimensions 2 2 Legend...

Page 6: ...pump material Do not pump any liquids containing particles of diameter greater than 2 mm Do not use pumps under water Do not allow pumps to run without liquid for longer than one minute Only use genui...

Page 7: ...AR 2000 B NIROSTAR 2001 B Max flow rate in L min 30 30 60 60 30 30 60 60 30 30 60 60 Max pressure 4 bar Connections In Out inches and nominal width in mm 19 19 1 20 1 20 19 19 1 20 1 20 19 19 1 20 1 2...

Page 8: ...e bearing with V belt drive 02 hydraulic drive 14 DC 12 V 24 DC 24 V 34 DC 48 V 63 electr motor 230 V with special shaft 64 electr motor 230 V with standard shaft 73 electr motor 400 V with special sh...

Page 9: ...le tearproof durable FKM or FPM Fluorocarbon rubber Viton Fluorel High temperatures acids and alkalis Very good chemical resistance low mechanical strength 4 Transportation and unpacking After unpacki...

Page 10: ...rew pressure line onto the side marked Aus 3 Verify that the connections are leaktight In the case of a suction height of more than 3 metres fit foot valve in the suction line in order to prevent drai...

Page 11: ...le be driven with the following drive systems Power drill V belt drive Gear motor Hydraulic motor Air pressure motor Ensure correct speed and output of the drive system When using external drive syste...

Page 12: ...or the connection of the pump with the motor optional accessories see parts list from item 200 is necessary Caution Material damage due to incorrect alignment of the pump If the claw coupling is being...

Page 13: ...mmissioning Open pressure line To start the pump switch on drive During the intake process the pressure side must not be closed otherwise intake will not be possible Caution Material damage due to ove...

Page 14: ...g with impeller and rear side disc off the shaft 8 2 2 Series 2001 A and 2001 B 1 Disconnect line connections 2 Remove bolts and nuts 3 Remove feet 4 Remove cover with shaft and lateral discs on both...

Page 15: ...onto the shaft 3 Place front side disc into the recess and push cover onto this 4 Insert and tighten bolts 5 Attach lines The lateral discs and O rings must lie precisely in the recesses to ensure tha...

Page 16: ...h the flow control the flow rate of the pump can be controlled and adjusted to a specific quantity setting screw Flow rate measurement is based on the principle of a floater connected to a spring The...

Page 17: ...beneath the connector plug Remove connector plug and turn setting screw with a small screw driver turn right for higher pressure turn left for lower pressure Switch hysteresis can not be adjusted Tec...

Page 18: ...ether part is in place and insert or replace defective component Impeller blocked Fill pump with the medium to be pumped Impeller clogged up or macerated Use an impeller appropriate to the medium Pump...

Page 19: ...ZUWA Impeller Pumps 19 12 Performance curves...

Page 20: ...ZUWA Zumpe GmbH Franz Fuchs Stra e 13 17 D 83410 Laufen Telefon 49 8682 8934 0 Fax 49 8682 8934 34 E Mail info zuwa de Internet www zuwa de 2008 ZUWA...

Reviews: