6.0 Remote Control Function: (CONSOLE)
H4X4-4K18G support RS232 and TCP/IP control by same command as below:
6.1
For RS232 CONSOLE:
Connect the RS232 CONSOLE port to the COM port of the host by a F/M RS232 straight cable (pin 2 to pin 2; pin 3 to pin 3, pin
5 to pin 5).
Communication format is 9600,8, N, 1 (9600 bps, 8 data bits, no parity check, 1 stop bit)
For Ethernet TCP/IP(Winsock)
Default IP address: 192.168.0.10, Port:47011
6.2 Operation Instruction format:
C
△
(Space) + Par Enter
[Command]
[Description]
POWER
△
[y]
Power on/off
TX1
△
[n]
Set Input #n to output 1
TX2
△
[n]
Set Input #n to output 2
TX3
△
[n]
Set Input #n to output 3
TX4
△
[n]
Set Input #n to output 4
IR_ID
△
[p]
Set IR remote ID
SAVE
△
[p]
Save scene to #n
LOAD
△
[p]
Load scene from #n
LOCK
△
[y]
Panel button& IR remote control Lock/Unlock
SET_DHCP
△
[y]
DHCP client on/off
IPADDRESS
△
[x.x.x.x]
Set Matrix IP address
SUBNETMASK
△
[x.x.x.x]
Set Matrix subnet mask
GATEWAY
△
[x.x.x.x]
Set Matrix gateway
MEDIATYPE
△
[z]
Network speed select
MACFILTER
△
[y]
MAC filter on/off
STATUS
Show connection status
VERSION
Show firmware version
HELP
Help
[Symbol]
[Parameter]
n
00=off, 01~04=1~4
p
00~09=0~9
x
0~255
y
00=off, 01=on
z
00=auto, 01=10M, 02=100M
Example:
-To route input 4 to output 1, send the following string:
TX1
△
04Enter
-To put matrix in standby, send the following string:
POWER
△
00Enter