ZUUM H4X4-4K18G Manual Download Page 13

 

 

13 

                                                                                                                www.zuum.life                                                                                           

ZM1072020

 

   

 

l

 

Save:

 Save 10 sets of channel settings 

l

 

Load:

 Reload 1 of the channel settings 

l

 

Update

: Refresh the status of Load 

l

 

Back

: Back to 

Advanced

 page

 

 
 

Specification: 

 

MODEL 

H4X4-4K18G 

HDMI Resolution support 

4K@60Hz 4:4:4 18Gbps

6Gbps per color

 

1080p@60Hz 16bit

3D

HDR

Dolby vision 

Audio format support 

LPCM 7.1 @ 192KHz

Dolby TrueHD

 

ATMOS

DTS-HD MA

DTS:X 

Video Input Interface 

HDMI Type A x 4 

Video Output Interface 

HDMI Type A x 4 

Audio Output Interface 

RCA x 4 

IR Output Interface 

3.5mm Phone Jack x 1 

Ethernet Interface 

RJ45 x 1 

RS-232 Input/output Interface 

DB9 x 1(CONSOLE) 

IR Receive Angle 

± 45 degree 

IR Receive Distance 

5M 

Power Adapter 

DC 12V 4.2A 

Power Consumption 

2.8A 

Temperature 

Operation: 32 to 131°F, Storage: -4 to 185°F, Humidity: up to 95% 

Dimension                    inches 

19.01” x 7.24” x 1.73” 

Weight                            lbs 

4.85 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do you Need Technical Support? 

ZUUM

 is proud to offer free technical support to ensure your product is operating correctly. 

If you are experiencing difficulties setting up this product, please call us for assistance 1-888-861-7351 or visit 

www.zuum.life

 

Summary of Contents for H4X4-4K18G

Page 1: ...bps per color Support HDR10 Dolby Vision HLG Supports up to Dolby TrueHD Dolby ATMOS DTS HD MA DTS X LPCM 7 1 192KHz Supports ARC Audio Return Channel Multiple control methods Front panel buttons IR remote control Web UI Control and RS232 Control Built in LCM screen LED button at front panel provides quick view of all port connection Rack mountable 1U design S PDIF coaxial audio outputs allow audi...

Page 2: ...n Save Load scene ALL Button Select all outputs OFF Button Turn off select output 5 OUTPUT Buttons Blue ON Press these buttons to select the desired output Monitor connected OFF No monitor connected 6 INPUT Buttons Blue ON Press these buttons to select the desired input Video input detected OFF No video input 1 INPUT HDMI N A HDMI input port 1 4 2 SPDIF N A SPDIF audio output port 1 4 OUTPUT HDMI ...

Page 3: ... selection press ENTER to execute Key Lock Press MENU button for 3 seconds to enable disable key lock function Main MENU Option 1 SWITCH 2 SCENE 3 EDID 4 ETHERNET 5 REMOTE ID 6 AUDIO SELECT 7 SYSTEM INFO 8 USB UPDATE Operation l Press UP or DOWN key to move to select an item for setting and press ENTER key to enter into subpage l When the selected sub page setting is completed press the MENU butto...

Page 4: ... to select port number 1 4 to save or use Up Down button to select 5 10 LOAD Reload saved scenes press UP or DOWN to select the number and ENTER to load It will show input number and status of audio selection At main screen you could use IR01 remote button B to enter SCENE function button 1 4 input to select port number 1 4 to load or use Up Down button to select 5 10 4 3 EDID Default LPCM 2CH Bec...

Page 5: ...4 Ethernet 1 IP ADDRESS 2 SUBNET MASK 3 GATEWAY 4 DHCP CLIENT 5 MEDIA TYPE 6 MAC FILTER IP Address Default 192 168 0 10 This function can be setup MATRIX host intranet IP Address press ENTER the left most number of second row will flash then press the UP or DOWN button to change the numbers press LEFT or RIGHT to move to another location the move to a position number will flash press ENTER to comp...

Page 6: ...ATRIX host intranet Media Type press the ENTER the second row will flash then press the UP or DOWN button to select 10M 100M AUTO press ENTER to complete the setting MAC Filter Default Disable MAC Filter can be setup with registered MAC Address in order to connect the MATRIX host Web UI MAC Address required by the Web page to fill in this function can only be setup at DISABLE ENABLE then to press ...

Page 7: ...7 IN4 V1 00 8 OUT1 V1 00 9 OUT2 V1 00 10 OUT3 V1 00 11 OUT4 V1 00 5 0 Remote Control Function IR01 5 1 To command the matrix locally setup the remote control IR01 ID with the same code of the Matrix see 4 5 The default code is 4 Power 4 5 2 Warning These settings have to be done the first time you use the IR01 or when you change the batteries l IR ID setup press and hold POWER button then press Nu...

Page 8: ...ut 1 Output 2 Output 3 Output 4 N A N A Input 1 Input 2 Input 3 OFF Input 4 For example to switch output port 1 to input port 4 press 1 OUTPUT 1 and then press 7 INPUT 4 Using quick key operation LCM screen will jump to the output input setting page it will not allow you to use the front panel button to operate the H4X4 4K18G Matrix ...

Page 9: ...o output 1 TX2 n Set Input n to output 2 TX3 n Set Input n to output 3 TX4 n Set Input n to output 4 IR_ID p Set IR remote ID SAVE p Save scene to n LOAD p Load scene from n LOCK y Panel button IR remote control Lock Unlock SET_DHCP y DHCP client on off IPADDRESS x x x x Set Matrix IP address SUBNETMASK x x x x Set Matrix subnet mask GATEWAY x x x x Set Matrix gateway MEDIATYPE z Network speed sel...

Page 10: ...nput IP Address on a web page you can link to the Web UI of the MATRIX host 4 Web UI Operation SWITCH SETTING Power Control MATRIX power on and standby Output Display output 1 4 it can change the display name by the Aliases page Input Display input 1 4 this field is a drop down menu a drop down menu includes Input 1 4 and OFF It can change the display name by the Aliases page Reload Get MATRIX hos...

Page 11: ...me to avoid long time linking and another user cannot use When over the setting link time the terminal will automatically disconnect the link 0 no time setup 1 255 Minute time range that can be setup Scene Click to enter Scene setup page MAC Filter Enter to MAC Filter to setup page Aliases Enter to Aliases to setup page Device Name Can change device name Back Jump back SWITCH SETTING page Online T...

Page 12: ... MAC Filter can be setup as registered MAC Addresses to link MATRIX host Web UI The max is up to 10 MAC address groups l After MAC Address fill in select Enable and press Apply to complete the setting l Press Back jump to advanced page Scene ...

Page 13: ...HDMI Type A x 4 Audio Output Interface RCA x 4 IR Output Interface 3 5mm Phone Jack x 1 Ethernet Interface RJ45 x 1 RS 232 Input output Interface DB9 x 1 CONSOLE IR Receive Angle 45 degree IR Receive Distance 5M Power Adapter DC 12V 4 2A Power Consumption 2 8A Temperature Operation 32 to 131 F Storage 4 to 185 F Humidity up to 95 Dimension inches 19 01 x 7 24 x 1 73 Weight lbs 4 85 Do you Need Tec...