3.3 Panel button Details:   

OUTPUT 1~10 

  _INPUT 1~10   

Press OUTPUT 1~10 to select output port then the input at IN line of LCD will blink, press INPUT 1~10 to select input port to switch the channel   

ALL:   

Press ALL button, the IN line of LCD will blink, press INPUT 1~10 to select input port to all output port. ENTER 

OFF:   

Press OFF button, the IN line of LCD will blink, press ALL or OUTPUT 1~10 to select which port to turn off. ENTER 

EDID:   

Press EDID button, it will show “From OUTPUT” at second line of LCD and the channel number will blink, press OUTPUT 1~10 to select which port to copy 

EDID. (NOTE: See section 4.4 for EDID details.) 

LOCK:   

Press LOCK until LOCK LED is on. Located above button. The panel buttons and IR remote will be locked or non working. Press LOCK until LOCK LED is off 

to unlock. Panel buttons and IR remote will work again. 

 

3.3

 

LCD Panel Function: 

 

Power on Main Screen 

When the power is on and the main screen appears   

 

 

Channel Setting on Main Screen 

The Matrix will jump to channel setting screen after 10 seconds, press the MENU key to enter the main   

 

 

 

Main MENU Option: 

*1 - SWITCH

 

*

2 - SCENE 

*

3 - ETHERNET 

*

4 - EDID 

*

5 - REMOTE ID 

*

6 - VERSION 

 

 

 

10X10 HDMI MATRIX

 

OUT 1    2    3    4    5    6    7    8    9    10 

IN    1    2    3    4    5    6    7    8    9

   

10

 

 

Summary of Contents for H10X10

Page 1: ...10 devices through Ethernet control IR remote control RS 232 and the front panel 1 0 Features Connect up to 10 HDMI sources to 10 HDMI displays TV s High definition video up to 4K2K 60Hz 8bits 1080p 60Hz 12bits Audio supports up to LPCM 7 1 192KHz Dolby TrueHD DTS HD Easy to use front panel control or included remote control for switching sources Built in Ethernet control assign IP or set up as DH...

Page 2: ...ER Power on Blue Standby Red UP Up DOWN Down LEFT Left RIGHT Right ENTER Select confirm key MENU Back to main channel setting EDID Copy EDID LOCK Button lock ALL Set selected input channel to all output When you press ALL the second line of LCD will show IN and flashing select the input 1 10 or ALL Then press ENTER OFF Turn off selected output could be 1 10 or ALL When you press OFF the second lin...

Page 3: ...PUT at second line of LCD and the channel number will blink press OUTPUT 1 10 to select which port to copy EDID NOTE See section 4 4 for EDID details LOCK Press LOCK until LOCK LED is on Located above button The panel buttons and IR remote will be locked or non working Press LOCK until LOCK LED is off to unlock Panel buttons and IR remote will work again 3 3 LCD Panel Function Power on Main Screen...

Page 4: ...ey then the LCD second line INPUT will flash Press LEFT or RIGHT button to select the output to be modified Then press Up or Down button to select the input port After that press ENTER to confirm setting It also works with INPUT OUTPUT button of panel or IR remote 4 2 Scene SCENE function provide 10 sets of channel setting to fast reload for different application Load Reload saved scene press UP o...

Page 5: ...Default 192 168 0 1 This function can setup MATRIX host intranet Gateway press the ENTER the left most number of second row will flash then press the UP or DOWN button to change the numbers Press the ENTER press LEFT or RIGHT to move to another location the move to a position number will flash press ENTER to complete the setting DHCP Client Default Disable When DHCP Clients setup to Enable the MAT...

Page 6: ...x provides COPY MODE to copy TV EDID for input source reference When using the copy mode recommend copying the lowest resolution TV EDID Otherwise it may cause no picture display if the TV resolution is not able to support higher resolution After entering COPY MODE menu press UP or DOWN button to select the OUTPUT TV 1 to 10 Then press ENTER to confirm 4 5 Remote ID Default IR ID 4 This function m...

Page 7: ...then press Number key NOTE In Standby mode The IR Remote can only control POWER on off Remote control button define Symbol Function Power ON Standby same as Matrix Left Left same as Matrix Right Right same as Matrix Up Up same as Matrix Down Down same as Matrix Enter Confirm same as Matrix Menu Menu same as Matrix Quick key 1 Quick key 2 Quick key 3 Quick key 4 Quick key 5 Quick key 6 Quick key 7 ...

Page 8: ...ormat Command Space Parameter Enter COMMAND DESCRIPTION POWER y Power on off TX n n Set RXn to TXn RX n m m m m Set RXn to multiple TXm m m m MATRIX_ID p Set Matrix IR ID EDID_COPY n Copy EDID from TX n SAVE n Save setting to n LOAD in Load setting from n KEY y Panel buttons IR remote control Lock Unlock DHCP y DHCP client on off IP_ADDRESS x x x x Set Matrix IP address SUBNET_MASK x x x x Set Mat...

Page 9: ...Function Initial IP Configuration 1 Setup MATRIX IP Address based on 4 3 ETHERNET section NOTE If you set by DHCP go back to ETHERNET IP address to confirm IP to enter into browser 2 Input IP Address on a web page so you can link to the Web UI of the MATRIX host 3 Web UI Operation below Switch Settings POWER Control MATRIX power on and standby OUTPUT Display output 1 10 you can change the display ...

Page 10: ...nection will support 4 users on line at same time this function can setup the connect time to avoid long connections with users When over the set connect time the terminal will automatically disconnect the link 0 no time setup 1 255 Minute time range that can be setup DEVICE NAME Can change device name MAC ADDRESS Click to enter MAC Filter setup page ONLINE Terminal connection users display the ma...

Page 11: ...ng after changes The new name will update and correspond to SWITCH SETTING page Output Input Press Back jump back to advanced page MAC Filter MAC Filter can setup registered MAC Address to link MATRIX host Web UI up to 10 MAC groups After MAC Address entry select Enable and click Apply to complete the setting Press Back to advanced page ...

Page 12: ...Adapter DC 12V 6 7 Amp Power Consumption 5 Amp Temperature Operation 0 to 55 C Storage 20 to 85 C Humidity up to 95 Dimensions mm 483 x 197 x 88 Weight grams 3900 Memory Save Save 10 sets of channel settings Load Reload 1 of the channel settings Back Back to Advanced page Specifications Do you Need Technical Support ZUUM is proud to offer free technical support to ensure your product is operating ...