7.) 

VISUAL INDICATOR GUIDE

USER-IN-VIEW L.E.D. 

Yellow light flashes 3 times – after

5-second delay – when a user is in view. The yellow light

flashes constantly when a user is in view during the 10-minute

start-up sequence.

OBJECT LOCK SENSOR

BATTERY L.E.D. 

Red light flashes indicating it is time to

replace batteries with 4 new “C” batteries.

COURTESY MANUAL FLUSH BUTTON 

Allows manual

activation of flush when needed.

STEP A 

Use battery compartment wrench 

to remove battery compartment tray.

STEP B 

Pull cover off by rotating bat-

tery side forward and out.

STEP C 

Sensor Adjustor Tool comes in a 

built-in storage pocket. Replace after use.

8.) 

ADJUSTING YOUR E-Z FLUSH

Figure 6

6.) 

ACTIVATION

Using supplied battery compartment wrench,

remove battery compartment from the E-Z

Flush™ unit.

Load batteries into compartment tray (note

position of batteries in tray), and reinstall

battery tray into the E-Z Flush unit.

Secure  tray  with  battery  compartment  wrench. The  last  three 

turns of the wrench will activate the E-Z Flush unit.  The E-Z Flush 

System is now operational.

Your E-Z Flush unit comes preset from the factory.  If special 

circumstances require adjustment of the activation distance, see 

Appendix A – Adjusting Your E-Z Flush.

The E-Z Flush unit has a 10-minute start-up sequence in which 

the Object Lock Sensor will flash the User-In-View 

yellow L.E.D.

continuously as long as a user is in view.  After the start-up se-

quence is completed and when the Object Lock Sensor has a user 

in view, the User-In-View 

yellow L.E.D.

 will flash only 3 times after 

a 5-second delay.  This delay prevents needless flushes when 

someone walks by.  Sensor units should not be located across 

from each other or in close proximity to highly reflective surfaces.

Summary of Contents for ZER6000AV-CPM

Page 1: ...or his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods All weights ...

Page 2: ...g compounds should be used on male NPT threads only 2 Prior to inserting the flush valve tailpiece B into stop valve be certain that the O ring seal C is located in O ring seal groove at the end of the tailpiece and the locking nut D and locking snap ring E are located as shown Care should be taken not to damage the O ring when inserting the tailpiece into the stop valve If lubrication is needed w...

Page 3: ...nt from the E Z Flush unit Load batteries into compartment tray note position of batteries in tray and reinstall battery tray into the E Z Flush unit Secure tray with battery compartment wrench The last three turns of the wrench will activate the E Z Flush unit The E Z Flush System is now operational Your E Z Flush unit comes preset from the factory If special circumstances require adjustment of t...

Page 4: ...Press sensor range reset button the yellow L E D will flash continuously when it has an object in view for the 10 minute reset period 5 Stand at desired activation distance 6 Use sensor adjustor tool and turn Distance Adjustment Screw all the way down and then turn slowly up until yellow L E D begins to flash 7 Ensure Object Lock Sensor is not detecting stall door or wall by closing door stepping ...

Page 5: ...essed Yellow L E D light will flash only 3 times acknowledging a user is in view after the 10 minute start up mode Red L E D light flashes Batteries need replacing Replace batteries Not enough water to fixture or too much water to fixture Diaphragm damaged or valve control stop improperly adjusted Replace diaphragm and or adjust valve control stop Valve will not operate Object Lock Sensor range se...

Page 6: ...Kit 3 0 gal flush P6000 EUA FF Repair Parts Inside Parts Product No Urinal Relief Valve Item 12 P6000 EU13 Closet Relief Valve Item 12 P6000 EC13 Flush Connections and Spud Coupling Kits Product No Flush Tube Assembly for Flush Valves Includes Items 15 19 Specify Diameter and Length P6000 A Vacuum Breaker Repair Kit Item 17 P6000 B Spud Coupling Assembly Includes Items 20 23 Specify Size P6000 H C...

Reviews: