PRIOR TO INSTALLATION

Prior to installing the ZER Flushometer, install the

items listed below:

• Closet or urinal fixture

• Drain line

• Water supply line

IMPORTANT:

• ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH 

APPLICABLE CODES AND REGULATIONS.

• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN 

ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.

• FLUSH ALL WATER LINES PRIOR TO OPERATION (See 

Step 9).

• DIRT AND DEBRIS CAN CAUSE FLUSH VALVE TO RUN 

CONTINUOUSLY.

The ZER is designed to operate with 20 to 80 psi (138 to 552 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO 

THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for pressure requirements. 

Protect the chrome or special finish of this flushometer. DO NOT USE TOOTHED TOOLS TO INSTALL OR SERVICE THE VALVE.

1.) 

Install stop valve assembly 

(A)

 using proper size supply 

escutcheon and sweat solder adapter kit if applicable.  Thread 

sealing compounds should be used on male NPT threads only.

2.) 

Prior to inserting the flush valve tailpiece 

(B)

 into stop valve, 

be certain that the O-ring seal 

(C)

 is located in O-ring seal groove 

at the end of the tailpiece and the locking nut 

(D) 

and locking 

snap ring 

(E)

 are located as shown.  Care should be taken not 

to damage the O-ring when inserting the tailpiece into the stop 

valve. If lubrication is needed, wetting the O-ring with water will 

be sufficient.

3.) 

Insert the flush valve tailpiece 

(B)

 into the stop valve 

(A)

 and 

hand tighten the lock nut 

(D)

 to the stop valve. Plumb the entire 

unit.

4.) 

Determine the length of vacuum breaker tube 

(F)

 required

to join the flush valve and fixture spud.  Cut the vacuum breaker 

tube, if required, to this length.  Assemble the vacuum breaker 

tube assembly and spud nut assembly to the flush valve and 

fixture spud.

5.) 

Hand tighten spud nut and vacuum breaker tube nut to fixture 

and flush valve.  Adjust the valve assembly for plumb.  Tighten 

fixture spud nut, vacuum breaker tube nut and lock nut with a 

wrench. 

 Do not turn water on until batteries are inserted – 

see 6.

Figure 1

Figure 3

Figure 2

Figure 4

E

C

A

D

F

B

B

D

A

Summary of Contents for ZER6000AV-CPM

Page 1: ...or his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods All weights ...

Page 2: ...g compounds should be used on male NPT threads only 2 Prior to inserting the flush valve tailpiece B into stop valve be certain that the O ring seal C is located in O ring seal groove at the end of the tailpiece and the locking nut D and locking snap ring E are located as shown Care should be taken not to damage the O ring when inserting the tailpiece into the stop valve If lubrication is needed w...

Page 3: ...nt from the E Z Flush unit Load batteries into compartment tray note position of batteries in tray and reinstall battery tray into the E Z Flush unit Secure tray with battery compartment wrench The last three turns of the wrench will activate the E Z Flush unit The E Z Flush System is now operational Your E Z Flush unit comes preset from the factory If special circumstances require adjustment of t...

Page 4: ...Press sensor range reset button the yellow L E D will flash continuously when it has an object in view for the 10 minute reset period 5 Stand at desired activation distance 6 Use sensor adjustor tool and turn Distance Adjustment Screw all the way down and then turn slowly up until yellow L E D begins to flash 7 Ensure Object Lock Sensor is not detecting stall door or wall by closing door stepping ...

Page 5: ...essed Yellow L E D light will flash only 3 times acknowledging a user is in view after the 10 minute start up mode Red L E D light flashes Batteries need replacing Replace batteries Not enough water to fixture or too much water to fixture Diaphragm damaged or valve control stop improperly adjusted Replace diaphragm and or adjust valve control stop Valve will not operate Object Lock Sensor range se...

Page 6: ...Kit 3 0 gal flush P6000 EUA FF Repair Parts Inside Parts Product No Urinal Relief Valve Item 12 P6000 EU13 Closet Relief Valve Item 12 P6000 EC13 Flush Connections and Spud Coupling Kits Product No Flush Tube Assembly for Flush Valves Includes Items 15 19 Specify Diameter and Length P6000 A Vacuum Breaker Repair Kit Item 17 P6000 B Spud Coupling Assembly Includes Items 20 23 Specify Size P6000 H C...

Reviews: