background image

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of five years from the date 

of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are notified in 

writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and 

used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages whatsoever, includ

-

ing incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the defective goods. Before 

installation and use, the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk 

and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability is expressly excluded. If the 

products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a period of three years and shall be 

limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are approximate and are not guaranteed.

Sensor-Operated Concealed Systems

Sensor-Operated Exposed Systems

ZEMS6000AV

ZEMS6200AV

ZEMS6000AV-2

ZEMS6200AV-2

ZEMS6000AV-3

ZEMS6200AV-3

ZEMS6001AV

ZEMS6201AV

ZEMS6003AV

ZEMS6203AV

AquaSense

®

ZEMS G2 Series

Automatic Systems Sensor-Operated

Flushometer

Installation, Operation, Maintenance

and Parts Manual

Patented and Patents Pending

ZEMS6140AV

ZEMS6240AV

ZEMS6152AV

ZEMS6252AV

ZEMS6153AV

ZEMS6253AV

ZEMS6190AV

ZEMS6290AV

ZEMS6195AV

ZEMS6295AV

ZEMS6197AV

ZEMS6297AV

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

Summary of Contents for ZEMS6000AV

Page 1: ...n connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods All weights stated in our catalogs and lists are approximate and are not guaranteed Sensor ...

Page 2: ... ACTUATOR 103 4 273 MAX 33 4 95 MIN AS SPECIFIED 21 533 9 229 43 4 121 TOP OF FIXTURE 1 I P S SUPPLY SENSOR BOX SENSOR BOX FINISHED WALL 41 4 108 MAX 21 4 57 MIN 111 2 292 4 102 43 4 121 TOP OF FIXTURE 3 4 I P S SUPPLY MOTOR ACTUATOR ZEMS6201 11 4 TUBE ZEMS6203 3 4 TUBE SENSOR BOX FINISHED WALL 41 4 108 MAX 21 4 57 MIN 111 2 292 21 533 43 4 121 TOP OF FIXTURE SENSOR BOX 41 4 108 MAX 21 4 57 MIN ZE...

Page 3: ...stalling the Zurn Automatic Sensor equipped Flushometer install the items listed below as illustrated in Figures 1 through 3 2 gang electrical box 4 x 4 x 2 1 8 use Steel City 52171 N box and 52 C 18 device cover or equivalent for sensor with closet or urinal installs Optional Single gang electrical outlet for plug in power converter Electrical wiring to the power converter outlet 120 VAC 35 watts...

Page 4: ...supplied with a six foot cord If additional wire is needed from the Power Converter to the Flushometer s use 18 AWG not provided Do not supply power to the Power Converter until installation of actuator sensor and Flushometer is completed and checked Proper polarity must be observed or damage to one or all components will result ACTUATOR YEL BLU ORG ACTUATOR ACTUATOR SENSOR SENSOR SENSOR HW6 BLACK...

Page 5: ...or Connectors are keyed to insure correct polarity Ensure that the sensor is mounted in the orientation shown with lens angled downward see Figure 4 STEP 3 Install Top Bracket Figure 3 Fasten the Top Bracket to the electrical box using 2 screws provided Ensure that bracket is mounted in the orientation shown with face angled upward see Figure 4 STEP 4 Install Cover Plate Figure 4 Perform a trial f...

Page 6: ...ine ensure all stop valves are closed off tight by using a flathead screwdriver and turning the stop valve adjustment screw clockwise Apply sealing compound here Control Stop Installation Instructions STEP 2 When all stop valves are properly connected to the water supply line and water pressure is available open the control stop using a flathead screwdriver and turning the stop valve adjustment sc...

Page 7: ...ed away from the valve body at this time until the actuator push rod clears the handle port flange The actuator can now be mounted to the flush valve and tightened 6 Push escutcheon back to wall and tighten setscrew NOTE See Figure 2 for typical installation including optional mini junction box H G Vacuum Breaker Tube Nut Spud Nut Slip Gasket Rubber Gasket Spud Escutcheon Figure 8 ZEMS6190 ZEMS629...

Page 8: ...SS and HOLD button for 10 seconds or until the LED turns solid Unit will blink four times and flush once while button is being held 3 RELEASE finger after LED turns solid 4 PRESS and HOLD button when LED starts blinking 5 RELEASE finger when LED turns solid 6 Set target at desired distance No less than 16 from sensor face and verify NO other objects are in view of sensor face 7 Keep target steady ...

Page 9: ...hanism to seal 3 Pressure is inadequate or has dropped below minimum operating range Steps should be taken to increase the line pressure Water splashes out of fixture 1 Supply volume is more than is necessary 1 Adjust downward on control stop 2 Lime accumulation on vortex or spreader holes of fixture 2 Remove the lime build up Flush is not considered quiet 1 Control stop may not be adjusted for qu...

Page 10: ...S6290 ZEMS6195 ZEMS6295 ZEMS6197 ZEMS6297 ZEMS6140 ZEMS6240 ZEMS6153 ZEMS6253 ZEMS6152 ZEMS6252 ZEMS6000 ZEMS6000 1 ZEMS6000 2 ZEMS6000 3 ZEMS6001 ZEMS6003 ZEMS6200 ZEMS6200 1 ZEMS6200 2 ZEMS6200 3 ZEMS6201 ZEMS6203 9 3 12A 12B 12C 12D 12D 12E 13A C 13C 13A 13A 14A 12F 12G 12G 15 16 15B 14A 14B 14A 8 15A 15A 7 ...

Page 11: ...sembly 12D P6000 1 A AA RB Rough Brass 1 1 2 X 12 1 2 Vacuum Breaker Assembly 12E P6000 A AA RB Rough Brass 1 1 2 X 5 Vacuum Breaker Assembly 12F P6001 10 A AA RB Rough Brass 1 1 4 X10 Vacuum Breaker Assembly 12G P6003 10 A AA RB Rough Brass 3 4 X 10 Vacuum Breaker Assembly 13A P6000 H 1 1 2 Spud Coupling Assembly 13B P6001 H 1 1 4 Spud Coupling Assembly 13C P6003 H 3 4 Spud Coupling Assembly 14A ...

Page 12: ...Cast Wall Escutcheon P6003 YC 3 4 Cast Wall Escutcheon 33 P6000 YB CVR 1 Supply Cover Tube P6003 YB CVR 3 4 Supply Cover Tube 34 P6000 YC SS Setscrew for Cast Wall Escutcheon 35 P6000 VC W VP 5 64 Allen Wrench 36 P6000 YBA 1 Sweat Solder Adapter P6003 YBA 3 4 Sweat Solder Adapter 37 P6000 YB 1 Sweat Solder Kit P6003 YB 3 4 Sweat Solder Kit Valve Repair Parts List Continues 42 39 39 38 41 42 ZURN I...