background image

FV606 Rev.  A 8/6/2018
Page 2

   

 

Overview:

Designed for modern commercial restrooms, the Sundara system delivers a superior user experience in both form and func-

tion. Crafted by world-class industrial designers Sundara combines seamless basin designs with curated faucets and soap 

dispensers, delivering a complete, easy to install hand washing solution.

Specifications:

Sundara

®

 Reef double basin lavatory system manufactured by Zurn Industries. Lavatory shall be mounted at standard height 

to conform with ANSI, UFAS, TAS and ADA Accessibility Standards. Counter and integral basin to be constructed of Sundara

®

 

solid surface resin with aluminum trihydrate and other additives conforming to CSA B45.5 / IAPMO Z124 and IAPMO IGC 

156 standards. Shroud enclosure is constructed of satin finished type 304, 18 gage stainless steel designed for easy access 

with vandal resistant hardware. Lavatory is furnished complete with 0.5 gpm spray aerator faucet (specify model in sensor or 

manual) and optional liquid soap dispenser (specify model), ½” quarter turn supply stops, 3/8” flexible supply risers, chrome 1 

¼” tail piece, and chrome 1 ¼” p-trap  for complete system operation. 

Paired Faucet Typical Specification 

(Refer to faucet manual for more details on specific model)

Voltage:            6 VDC Series [4 “AA” (Alkaline or Lithium) and/or external power option]

Sensor Range:  Self-calibrated, dependent upon sink depth and finish.

Operating Water Pressure: 10-125 psi

Operational Water Temperature: 33°F to 140°F (1°C to 60°C)

Aerator:  0.5 GPM Vandal-Resistant (Standard)

Paired Soap Dispenser Typical Specification 

(Refer to soap dispenser manual for more details on specific model)

Power Supply:            AC 110 V; DC 6V

Soap Viscosity:  100-3800 cps

Operating Temperature:  34

0

 - 131

0

F

Typical Dispensed Volume: 1.25 ml

Important Safety Information:

• Installer is responsible for ensuring the product is installed and conforms to all plumbing codes and ordinances. 

• Do not convert or modify this Zurn product yourself. All warranties will be voided.

• 

Water supply lines must be sized according to building design in order to provide adequate water supply for each fixture.

• Flush all water lines prior to making connections.

• Minimum 2 people required for the sink installation.

• Au minimum, 2 personnes sont requises pour l’installation du lavabo.

Prior to Installation:

• If applicable, carrier (Z1240 series) is installed behind the wall. 

• Hot and cold water supply lines are installed as per building codes.

• Care shall be taken when installing this product to prevent damage of any exposed or decorative surfaces.

• 

Measure the drain outlet from the floor.

Be sure the sink/lavatory/basin is clear from any objects upon making the sensor to electronics connection initiating the self-

calibration feature. The sink must be clear of any and all objects in order to calibrate appropriately (calibration time approx 30-

60sec). Note:  Not applicable to manual faucet installations.

S’assurer qu’aucun objet ne se trouve sur l’évier/le lavabo/le bac lors du branchement du capteur sur l’électronique, ce qui lance la 

fonction d’auto-étalonnage. Rien ne doit se trouver sur le lavabo pour permettre son auto-étalonnage correct (temps

d’étalonnage de 30 à 60 s environ).

Summary of Contents for Sundara Z5001.02

Page 1: ...he products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods All weights stated in our catalogs and lists are approximate and are not guaranteed NOTE READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT NOTE The information in this manual is subject to change at any tim...

Page 2: ...0 5 GPM Vandal Resistant Standard Paired Soap Dispenser Typical Specification Refer to soap dispenser manual for more details on specific model Power Supply AC 110 V DC 6V Soap Viscosity 100 3800 cps Operating Temperature 340 1310 F Typical Dispensed Volume 1 25 ml Important Safety Information Installer is responsible for ensuring the product is installed and conforms to all plumbing codes and ord...

Page 3: ...11 Soap Dispenser If Ordered 2 12 5 16 18 Screw for Mounting L Bracket to Basin 8 13 10 24 Screw for Drain Adapter and Shroud 10 14 6 32 Screw for Grid Drain 4 15 Coarse Screw for Wall Bracket 2 16 Flanged Socket Head Screw for Shroud 2 17 Oversize 5 16 Washer 8 18 10 Flat Washer for Drain Adapter and Shroud 10 19 3 8 16 Hex Bolt with washer 24 20 3 8 Toggle Never Drop Anchor 24 21 3 8 Fender Wash...

Page 4: ...FV606 Rev A 8 6 2018 Page 4 Plumbing and Electrical Rough Ins Note Installing the P trap outlet lower than 19 5 from finished floor will prevent the vandal shroud from being installed ...

Page 5: ...approximately 5 ft lbs of torque Warning Do not overtighten the screws Avertissement ne pas trop serrer les vis For ease of installion lay basin on its top surface on a cushioned surface Use T25 torx wrench to torque the screws approximately 4 5 complete turns and squeeze the gasket approximately 2 3 ft lbs of torque Warning Do not overtighten the screws Avertissement ne pas trop serrer les vis To...

Page 6: ...stallation For ease of installion lay basin on its back Refer to faucet installation guide for details For ease of installion lay basin on its back Install the soap spout on right or left soap hole as applicable Refer to soap dispenser installation guide for details ...

Page 7: ...plywood with the supplied bolts Install hanger bracket to wall per structural rough in Note An offset might be necessary on applications using tile to get the basin and mounting brackets flush with the wall and mating bracket The plywood should not be visible after basin and shroud installation The bracket needs to be checked for level after installation 21 19 20 Plywood Wall Stud Bolt supplied by...

Page 8: ...and Bottle Installation Refer to soap dispenser installation guide for details Installing with Carrier Option Warning Must be handled by at least 2 people Avertissement s y prendre à deux minimum Refer to Carrier Rough in Installation guide for details ...

Page 9: ...ion Align wall bracket as shown and install coarse screw on each side Mark the slots in the wall bracket on the wall 15 9 Use T10 Torx wrench to attach the grid drain to basin Torque screws until the screw heads are flushed with the screw pocket of grid drain Warning Do not overtighten the screws Avertissement ne pas trop serrer les vis Suggested Final Step Caulk Silicon lavatory to the finished w...

Page 10: ... previous lo cation Then fasten the wall bracket with 3 8 bolts through each holes and into the toggle bolts Place shroud on hanger hooks of wall bracket as shown Then position the pivot of the shroud through the hole in the wall bracket Note the shroud will likely need to be rotated upward slightly in order to install each pivot After one pivot is installed fasten the flange screw into the pivot ...

Page 11: ...posing solid surface basin with strong chemicals such as acetone based cleaners and solutions If surfaces are exposed to these chemicals quickly rinse the surface with water Repair Instructions Zurn recommends that damages should be repaired by certified solid surface fabricator or repair agents Blemishes to the basin surface such as scratches burnmarks and minor chipping can be repaired by sandin...

Reviews: