AQUASPEC FAUCETS

MODEL - Z80300-DZR SERIES

WALL MOUNTED SINGLE METERING FAUCET

FOR AS / NZS MARKET

TECHNICAL INFORMATION

FLOW:

  1.9 L/min; PRESET AT FACTORY TO 5 TO 8 SECONDS @ 

35

0 kPa ADJUSTABLE

 

MAXIMUM PRESSURE:

  

35

0 kPa

MAXIMUM TEMPERATURE:

  60

O

 

C

F

®

INSTALLATION INSTRUCTIONS

1.

THE WATER SUPPLY LINE MUST BE THOROUGHLY FLUSHED BEFORE FAUCET INSTALLATION.

2.

REMOVE FAUCET BODY FROM CARTON AND MOUNT TO 1/2” BSP FITTING.

3.

INSTALL HANDLE (#1A) ONTO STEM (#2C).  PUSH DOWN ON HANDLE (#1A) TO SEAT ON STEM (#2C) WHILE
TIGHTENING SET SCREW (#1B) USING 3/32” ALLEN WRENCH.

4.

TURN SUPPLY WATER ON AND OPERATE THE FAUCET WHILE CHECKING FOR LEAKS

5.

INSTALL  AERATOR ADAPTOR (#5) AND AERATOR (#6) INTO FAUCET AND HAND TIGHTEN.

6.

METERING CARTRIDGE IS FACTORY PRESET FOR A 5 TO 8 SECOND CYCLE AT 

35

0 kPa, IF ADJUSTMENT IS

NECESSARY, SEE “ADJUSTING THE FLOW” SECTION (PAGE 2).

*

IMPORTANT

THE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT

FOREIGN MATTER AND DEBRIS FROM CLOGGING AND/OR DAMAGING INTERNAL COMPONENTS AND THEREBY PREVENTING

 

THE FAUCET FROM FUNCTIONING PROPERLY

PROVISION SHALL BE MADE TO ENSURE THAT THE MAXIMUM OPERATING PRESSURE AT ANY OUTLET, OTHER THAN A FIRE

 

SERVICE OUTLET WITHIN A BUILDING,  DOES NOT EXCEED 

35

0 kPa.

NOTE: PRESSURES ABOVE 

35

0 kPa CAN CAUSE DAMAGE FROM WATER HAMMER, REDUCE LIFE OF APPLIANCES, TAPS

 

AND FITTINGS, AND CAN CAUSE EXCESSIVE NOISE IN THE SYSTEM.

PAGE 1 OF 4

ZURN.COM.AU

INST

2018

_Z-8

03

00

 Rev. 11/18

Summary of Contents for AQUASPEC Z80300-DZR Series

Page 1: ...CKING FOR LEAKS 5 INSTALL AERATORADAPTOR 5 AND AERATOR 6 INTO FAUCETAND HAND TIGHTEN 6 METERING CARTRIDGE IS FACTORY PRESET FOR A5 TO 8 SECOND CYCLE AT 350 kPa IF ADJUSTMENT IS NECESSARY SEE ADJUSTING THE FLOW SECTION PAGE 2 IMPORTANTTHE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT FOREIGNMATTERANDDEBRISFROMCLOGGINGAND ORDAMAGINGINTERNALCOMPONENTSANDTHEREBYPREVENTIN...

Page 2: ...RING CARTRIDGE CONTAMINATED OR DAMAGED METERING CARTRIDGEASSEMBLIES SHOULD BE REPLACED 2 7 REVERSE STEPS 2 1 THROUGH 2 5 FOR RE ASSEMBLY TIGHTEN CAP 2F WITH 1 1 8 HEX 6 POINT SOCKET UNTIL NO WATER IS LEAKING FROM UNDER THE HANDLE NUT ASSEMBLY WHEN THE FAUCET IS RUNNING HOLD DOWN HANDLE 1A WHILE TIGHTENING SET SCREW 1B TO ENSURE PROPER SEATING 3 IT MAY BE NECESSARY TO REPLACE OR BACK FLUSH THEAERAT...

Page 3: ...65001 E Ring 1 2B 60464001 Spring Seat 1 2C 60451003 Stem 1 2D 60447001 Spring 1 2E 60446001 Adjustment Nut 1 2F 60452001 Cap 1 2G 60456001 Stem Housing 1 2H 62499107 O Ring 1 2i 60458001 O Ring Retainer 1 3 G67874 Valve Sleeve Poppet Assembly 1 3A 58155020 O Ring 1 3B 81241001 Washer 1 4 61676010 DZR Body Single Flanged Wall Sink 1 5 93558001 Aerator Adaptor 1 6 60440001 0 5 GPM 1 9L Vandal Resis...

Page 4: ... GPM aerator Facuet may not shut off with aerator s 1 0 GPM Tighten handle nut using 1 1 8 hex 6 point socket to create seal and seat metering cartridge Do not over tighten Remove handle using 3 32 Allen wrench Rotate timing nut up CCW to shorten handle stroke and decrease cycle time Replace metering cartridge G67874 per Installation and Maintenance guide Supply stops not open Aerator contaminated...

Reviews: