AQUASPEC FAUCETS
MODEL - Z80300-DZR SERIES
WALL MOUNTED SINGLE METERING FAUCET
FOR AS / NZS MARKET
TECHNICAL INFORMATION
FLOW:
1.9 L/min; PRESET AT FACTORY TO 5 TO 8 SECONDS @
35
0 kPa ADJUSTABLE
MAXIMUM PRESSURE:
35
0 kPa
MAXIMUM TEMPERATURE:
60
O
C
F
®
INSTALLATION INSTRUCTIONS
1.
THE WATER SUPPLY LINE MUST BE THOROUGHLY FLUSHED BEFORE FAUCET INSTALLATION.
2.
REMOVE FAUCET BODY FROM CARTON AND MOUNT TO 1/2” BSP FITTING.
3.
INSTALL HANDLE (#1A) ONTO STEM (#2C). PUSH DOWN ON HANDLE (#1A) TO SEAT ON STEM (#2C) WHILE
TIGHTENING SET SCREW (#1B) USING 3/32” ALLEN WRENCH.
4.
TURN SUPPLY WATER ON AND OPERATE THE FAUCET WHILE CHECKING FOR LEAKS
5.
INSTALL AERATOR ADAPTOR (#5) AND AERATOR (#6) INTO FAUCET AND HAND TIGHTEN.
6.
METERING CARTRIDGE IS FACTORY PRESET FOR A 5 TO 8 SECOND CYCLE AT
35
0 kPa, IF ADJUSTMENT IS
NECESSARY, SEE “ADJUSTING THE FLOW” SECTION (PAGE 2).
*
IMPORTANT
THE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT
FOREIGN MATTER AND DEBRIS FROM CLOGGING AND/OR DAMAGING INTERNAL COMPONENTS AND THEREBY PREVENTING
THE FAUCET FROM FUNCTIONING PROPERLY
PROVISION SHALL BE MADE TO ENSURE THAT THE MAXIMUM OPERATING PRESSURE AT ANY OUTLET, OTHER THAN A FIRE
SERVICE OUTLET WITHIN A BUILDING, DOES NOT EXCEED
35
0 kPa.
NOTE: PRESSURES ABOVE
35
0 kPa CAN CAUSE DAMAGE FROM WATER HAMMER, REDUCE LIFE OF APPLIANCES, TAPS
AND FITTINGS, AND CAN CAUSE EXCESSIVE NOISE IN THE SYSTEM.
PAGE 1 OF 4
ZURN.COM.AU
INST
2018
_Z-8
03
00
Rev. 11/18