background image

®

AquaSense

®

ZTS6200

Automatic Sensor-Operated,

Battery-Powered Flushometer

Installation, Operation, Maintenance,  and

Parts Manual

Patented and Patents Pending

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of purchase. Decorative

finishes warranted for one year. We will replace at no costs goods that prove defective provided we are notified in writing of such defect and the goods are returned to

us prepaid at Sanford, NC, with evidence that they have been properly maintained and used in accordance with instructions. We shall not be responsible for any labor

charges or any loss, injury or damages whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement

of the defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and

liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability is expressly excluded. If the products sold hereunder are

“consumer products,” the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods.

All weights stated in our catalogs and lists are approximate and are not guaranteed.

AquaSense Exposed
Closet/Urinal System
ZTS6200-WS1
ZTS6203-WS1
Flushometer for Water Closet

Sensor-Operated, Battery-Powered  Valve

Summary of Contents for AquaSense ZTS6200

Page 1: ...foranylabor chargesoranyloss injuryordamageswhatsoever includingincidentalorconsequentialdamages Thesoleandexclusiveremedy shallbelimitedtothereplacement ofthedefectivegoods Beforeinstallationanduse thepurchasershalldeterminethesuitabilityoftheproductforhisintendeduseandthepurchaserassumesallriskand liability whatever in connection therewith Where permitted by law the implied warranty of merchanta...

Page 2: ...e 1 E C A D Before the supply water is turned on be sure all stop valves are closed off tight The stop valves can be opened and closed by using the adjusting screw S located at the center of the stop valve cap T Stop valve adjustments can only be made by us ing the adjusting screw S It is not necessary to remove the stop valve cap T when making adjustments If for any rea son it becomes necessary t...

Page 3: ...ation will occur when the valve senses an object person The LED will blink once At that point the valve is charged When object leaves view of the sensor valve will activate An eight second sensing cycle will prevent the valve from flushing needlessly when someone walks by If special circumstances require adjustment of the sensing distance see Appendix A Changing Activation Distance See Figure 9 B ...

Page 4: ...battery to the sensor Note There is a 5 second window after connecting the battery in which the sensor range adjust mode can be accessed 4 Place your hand in front of the sensor at a distance of 2 to 4 within 5 seconds after battery is reconnected to enter sensor range adjust mode 5 Initially the red light in the sensor will flash slowly 3 times approximately 2 seconds per flash Keep your hand in ...

Page 5: ...or other objects 1 Connectors between the electronic unit and solenoid are disconnected 2 Debris or scale in solenoid 3 The water supply pressure is too high 1 Debris or scale in piston 2 Sensor is dirty or covered 3 Sensor is picking up reflections from mirror or another object Solution 1 Replace battery 1 Increase the range 2 Decrease the range 3 Replace battery 4 Eliminate cause of reflection 1...

Page 6: ...onnections and Spud Coupling Kits Product No Flush Connection and Spud Coupling Items 15 18 P6000 H P6003 H VacuumBreaker Repair Kit Items 11 12 P6000 B VacuumBreaker Tube P6000 A CP VacuumBreaker Tube Nut P6000 AA CP Control Stop Repair Kit and Parts Product No Control Stop Repair Kit for 1 and 3 4 P6000 C SD CP Includes Items 14 20 Seal Seat for 1 and 3 4 Includes Item23 P6000 D42 Sw eat Solder ...