IMPORTANT NOTE:

Excessive water flow creates noise, while

too little flow will not satisfy the needs of the fixture. Proper
adjustment is made when:

1.  The plumbing fixture is cleansed after each flush without

splashing water out from the lip.

2.  A quiet flushing cycle is achieved.

After adjustment: Replace the Zurn stop cap screw cover.

CARE AND CLEANING INSTRUCTIONS

Do not

use abrasive or chemical cleaners to clean Flusho meters

and actuators as they may dull the luster and attack the chrome
or special decorative finishes. Use only mild soap and water, then
wipe dry with a clean cloth or towel.

While cleaning the bathroom tile, the Flushometer and actuator
should be protected from splattering of cleaner. Acids and 
cleaning fluids can discolor or remove chrome plating.

SENSOR FEATURES 

(See Step 10 for instructions.)

Courtesy Flush:

The Sensor will provide a courtesy flush two

seconds after a person is first detected. The courtesy flush removes
any residue from the fixture. The main flush will occur when the
user steps away from the fixture. The courtesy flush can be 
manually activated/deactivated at any time.

Automatic 24-Hour Flush:

The sensor will provide an automatic

flush 24 hours after the last user. The automatic flush can be
manually activated/deactivated at any time.

Indicator Lights:

The sensor unit has two operation lights, red

and green. The red light is lit when an object is detected. The
green is lit when the unit is flushing. The indicator lights can be
manually activated/deactivated at any time.

Maintenance Override

(For Maintenance Purposes): 

The sensor may be disabled for 10 minutes by placing a magnet
on the sensor lens for 3 to 5 seconds. After 10 minutes the sensor
will automatically resume functioning. Placing a magnet on the
sensor for one second will restore normal operation and also provide
a flush. These features are often desired for cleaning purposes.

Adjustable Range:

The viewing distance is adjustable from 12"

to 60".

Function Light:

If an object is in the viewing range for more than

30 minutes the red LED will blink. Range readjustment may be
required.

TROUBLE SHOOTING

PROBLEM

CAUSE

SOLUTION

No water comes from

The water supply line or

Open the water supply

the flush valve.

the angle stop is shut off.

or the angle stop.

The electric wire(s) is not connected.

Connect the wires.

The surface of the infrared

Clean the surface of

cover is stained.

the sensor cover.

There is a reflective surface 

Remove the reflective surface

in front of the sensor.

from in front of the sensor.

The detection range is not 

Adjust the detection range.

adjusted properly.

The infrared sensor or the 

Contact distributor for replacement.

actuator is out of order.                                               

Water does not stop flowing.

The by-pass hole in the

Clean the by-pass hole 

diaphragm is clogged.

in the diaphragm.

The sealing area of the 

Clean the sealing area 

diaphragm is dirty.

of the diaphragm.

Summary of Contents for AquaSense ZEMS6142AV

Page 1: ... prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determin...

Page 2: ...nections Sensor units should not be located across from each other or in close proximity to highly reflective surfaces The Zurn AquaVantage is designed to operate over the entire pressure range recommended by plumbing fixture manufacturers and will produce a metered flush when activated Protect the chrome or special finish of this AquaVantage Do not use toothed tools to install or service the valv...

Page 3: ...upply power to a maximum of eight flush valves for an approximate three day period during a power failure The Low Battery indicator will come on when the batteries have reached a caution level The Flushometers will function when the light is illuminated until the batteries are completely discharged The Low Battery light will illuminate even if the main power has not failed but the batteries have d...

Page 4: ...leave a minimum of 1 1 4 of scoriation to ensure engagement with compression coupling Assemble pipe elbows couplings slip washers rubber gaskets and flanges as illustrated in Figure 8 Hand tighten all couplings Once installation is completed tighten all connections STEP 5 Actuator Cable Installation Figures 9 and 10 1 Drill 1 3 4 diameter hole per Figure 9 2 Run fish tape from electrical box to 1 ...

Page 5: ...p Figures 11A and 11B Be certain power is off to prevent damage to electrical components Connect the sensor to the actuator and power converter exactly as shown in Figure 11A Figure 11B if battery backup is being used Also the wiring diagram on the battery backup may be used Double check that power converter polarity is correct STEP 7 Mount Automatic Sensor Figure 2 Install the Zurn Automatic Sens...

Page 6: ...c Sensor at the desired distance the red light will illuminate when you are within range Repeat adjustment procedure until the desired range is obtained Switch Settings Figure 13 The three switches control the following options They can be activated or deactivated by means of the switches down is on up is off Switch 1 Automatic Flush The unit will automatically flush 24 hours after last user Switc...

Page 7: ...ration lights red and green The red light is lit when an object is detected The green is lit when the unit is flushing The indicator lights can be manually activated deactivated at any time Maintenance Override For Maintenance Purposes The sensor may be disabled for 10 minutes by placing a magnet on the sensor lens for 3 to 5 seconds After 10 minutes the sensor will automatically resume functionin...

Page 8: ...m 5A P6000 QT1 4 CP 11 2 x 4 Outlet Tube CP 6 P6000 G TUBE Flange 7 P6000 HN CP 11 2 Slip Joint Coupling CP 8 P6000 QT4 11 2 Coupling S 30 Gasket 9 P6000 QT3 L RB 11 2 Outlet Tube RB specify L dim 10 Specify Series Valve Body CP specify valve type Item Part No Description 11 PESS6000 22 Sensor Cover Plate 12 PESS6000 23 Bracket 13 PESS6000 24 Push Button 14 PESS6000 25 Yoke 15 PEMS6000 26 Sensor 1...

Reviews: