ZURN AquaSense ZEMS6142AV Installation, Operation, Maintenance And Parts Manual Download Page 2

FV38-WCS • Page 2

Figure 1

PRIOR TO INSTALLATION

Prior to installing the Zurn Automatic Sensor-equipped Flushometer,
install the items listed below as illustrated in Figures 1 through 4.

•  2-gang electrical box (4 x 4 x 21⁄8 use Steel City #52171-N

box and #52-C-18 device cover or equivalent for sensor); see
paragraph entitled “Sensor Location.”

•  Single-gang electrical outlet for plug-in power converter.

•  Electrical wiring to the power converter outlet (120 VAC, 

35 watts service required for each power converter used).

• Closet fixture.

•  Zurn carrier system, Z1200 series or equal.

•  Single-gang box for Low Battery Indicator Light (optional).

IMPORTANT:

•  All electrical wiring is to be installed in accordance with

National/Local codes and regulations.

•  All plumbing is to be installed in accordance with applicable

codes and regulations.

•  Water supply lines must be sized to provide an adequate volume

of water for each fixture.

•  Flush all water lines prior to making connections.

•  Sensor units should not be located across from each other or

in close proximity to highly reflective surfaces.

The Zurn AquaVantage is designed to operate over the entire
pressure range recommended by plumbing fixture manufac turers
and will produce a metered flush when activated.

Protect the chrome or special finish of this AquaVantage. 

Do not use toothed tools to install or service the valve.

Also, see “Care and Cleaning” section of this manual.

SENSOR LOCATION 

(Figures 1 and 2)

Models ZEMS6000, ZEMS6140, ZEMS6142 and ZEMS6152

Locate the 2-gang electrical box on the centerline of the Flusho -
meter and 21" above the top of the closet fixture (use Steel City
#52171-N box and #52-C-18 device cover or equivalent).

Models ZEMS6000-2 and ZEMS6000-3

Locate the centerline of the 2-gang electrical box 3-1/4" to the left
of the centerline of the Flushometer and 15" (Model ZEMS6000-2)
or 17" (Model ZEMS6000-3) above the top of the closet fixture. (Use
Steel City #52171-N box and #52-C-18 device cover or equivalent).

All Models
NOTE:

Install plaster ring so screw holes are on left and right side

of box. Trim tiles to allow screw holes in plaster ring to show.

Summary of Contents for AquaSense ZEMS6142AV

Page 1: ... prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determin...

Page 2: ...nections Sensor units should not be located across from each other or in close proximity to highly reflective surfaces The Zurn AquaVantage is designed to operate over the entire pressure range recommended by plumbing fixture manufacturers and will produce a metered flush when activated Protect the chrome or special finish of this AquaVantage Do not use toothed tools to install or service the valv...

Page 3: ...upply power to a maximum of eight flush valves for an approximate three day period during a power failure The Low Battery indicator will come on when the batteries have reached a caution level The Flushometers will function when the light is illuminated until the batteries are completely discharged The Low Battery light will illuminate even if the main power has not failed but the batteries have d...

Page 4: ...leave a minimum of 1 1 4 of scoriation to ensure engagement with compression coupling Assemble pipe elbows couplings slip washers rubber gaskets and flanges as illustrated in Figure 8 Hand tighten all couplings Once installation is completed tighten all connections STEP 5 Actuator Cable Installation Figures 9 and 10 1 Drill 1 3 4 diameter hole per Figure 9 2 Run fish tape from electrical box to 1 ...

Page 5: ...p Figures 11A and 11B Be certain power is off to prevent damage to electrical components Connect the sensor to the actuator and power converter exactly as shown in Figure 11A Figure 11B if battery backup is being used Also the wiring diagram on the battery backup may be used Double check that power converter polarity is correct STEP 7 Mount Automatic Sensor Figure 2 Install the Zurn Automatic Sens...

Page 6: ...c Sensor at the desired distance the red light will illuminate when you are within range Repeat adjustment procedure until the desired range is obtained Switch Settings Figure 13 The three switches control the following options They can be activated or deactivated by means of the switches down is on up is off Switch 1 Automatic Flush The unit will automatically flush 24 hours after last user Switc...

Page 7: ...ration lights red and green The red light is lit when an object is detected The green is lit when the unit is flushing The indicator lights can be manually activated deactivated at any time Maintenance Override For Maintenance Purposes The sensor may be disabled for 10 minutes by placing a magnet on the sensor lens for 3 to 5 seconds After 10 minutes the sensor will automatically resume functionin...

Page 8: ...m 5A P6000 QT1 4 CP 11 2 x 4 Outlet Tube CP 6 P6000 G TUBE Flange 7 P6000 HN CP 11 2 Slip Joint Coupling CP 8 P6000 QT4 11 2 Coupling S 30 Gasket 9 P6000 QT3 L RB 11 2 Outlet Tube RB specify L dim 10 Specify Series Valve Body CP specify valve type Item Part No Description 11 PESS6000 22 Sensor Cover Plate 12 PESS6000 23 Bracket 13 PESS6000 24 Push Button 14 PESS6000 25 Yoke 15 PEMS6000 26 Sensor 1...

Reviews: