FV764 Rev. A 01/25/21
Page 2
Overview:
Designed for modern commercial restrooms, the AquaSense Z6933 sensor faucet delivers a superior user experience
in both form and function. This faucet maintains a sleek and simple design that is easy to install and a user-friendly
handwashing solution.
This faucet has been designed and manufactured to comply with Section 1417 of the Safe Drinking Water Act
(SDWA) which mandates the weighted average lead content of no more than 0.25% of the wetted surface.
NOTE: The information in this manual is subject to change at any time without notice. Installations may be performed
at different times of construction by different individuals. For this reason, these instructions should be left on-site
with the facility or maintenance manager.
Specifications:
Voltage:
6 VDC Series [4 “AA” (Alkaline)]
Sensor Range:
8”-10” (21-27cm)
Operating Water Pressure:
7.25-101 psi (0.05-0.7MPa)
Operational Water Temperature:
33°F to 131°F (1°C to 55°C)
Aerator:
Spray, 0.5 GPM (Standard)
Diameter of Inlet:
G1/2”
Important Safety Information:
• Installer is responsible for ensuring the product is installed and conforms to all plumbing codes and ordinances.
• Do not convert or modify this Zurn product yourself. All warranties will be voided.
• Water supply lines must be sized according to building designer in order to provide adequate water supply
for each fixture.
• Flush all water lines prior to making connections.
Be sure the water supply is turned on and the sink/lavatory/basin is clear from any objects upon making the sensor to electronics
connection initiating the self-calibration feature. The sink must be clear of any and all objects and water supply is turned on in order
to calibrate appropriately (calibration time approx 30-60sec) (the system will perform both a wet & dry calibration).
Prior to Installation:
Before installing your Zurn
®
AquaSense
®
Faucet: the items listed below should already be installed on site.
• Lavatory/sink
• Drain Line
• Hot and cold water supply line or pre-tempered water supply line.
•
Installer/Servicer should not use pipe dope or teflon/thread sealant anywhere on this product, most notably threads
and connection points.
• Care shall be taken when installing this product to prevent marring of any exposed or decorative surfaces.