Summary of Contents for AquaSense Z6920-XL-W2

Page 1: ... of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective g...

Page 2: ...For this reason these instructions should be left on site with the facility or maintenance manager Specifications Voltage 6 VDC Series 4 AA Alkaline or Lithium for faucet 4 VDC Series 4 AA Alkaline or Lithium for monitor Sensor Range Self calibrated dependent upon sink depth and finish Operating Water Pressure 10 125 psi Operational Water Temperature 33 F to 140 F 1 C to 60 C Aerator 1 5 GPM Vanda...

Page 3: ...lastic mounting washer 4 Assemble the electronics module Do not connect the electronic module to spout Spout Installation Instructions Cable to monitor 1 Install Monitor on wall surface within 2 feet radius of faucet with dry wall anchors screws or doubled sided VHB tape 2 Loosen lid screw with supplied 3mm Allen wrench Open lid and install supplied batteries Close lid and tighten lid screw 5 Tigh...

Page 4: ...eway is now ready to transmit data from your Zurn connected product 4 Zurn Gateways have been set to DHCP by default Please consult local IT support for possible additional access requirements for your network Step 3 Determining general Location for the Zurn Gateway Select a location central to all devices to be connected to this gateway Place the gateway as high as possible such as near the top o...

Page 5: ...Off Off Off Off Off Off On On Mode Select Sensing Mode Metering Mode Off On Sensor Sensitivity Low Off Normal On Mode A Off Mode B On Adjustable modes and features selection For further assistance with troubleshooting visit http www zurn com Problem Possible Cause Corrective Action Faucet is non responsive Battery voltage low or no power Change out batteries or verify power provided by ACA Sensor ...

Page 6: ...should clear within 1 hour or on next faucet activation Refresh web page by clicking on reload icon in the browser to clear the alert Step 2 If problem still present verify gateway is within range of LoRa Monitor and functioning see Gateway Troubleshooting section Step 3 If problem still present verify plumbSMART subscription status on product page s Details tab listed as Activated NETWORK Senet S...

Page 7: ...t data is properly presented in Chart Step 3 If problem still present contact building maintenance to verify sufficient water pressure in lines Step 4 If problem persists the LoRa Monitor may be paired to the incorrect fixture model Verify product image and model number from plumbSMART product page Details tab against model number cited on product literature and packaging If incorrect contact Zurn...

Page 8: ...3 8 Gooseneck Spout with Nut Item 1 P6900 GB 1 5 GPM Vandal Resistant Laminar Aerator Item 2 P6900 20J GN Z6920 No Lead Spout Base with Sensor Assembly Item 3A P6920 XL 2 Z6922 No Lead Spout Base with Sensor Assembly Item 3B P6922 XL 2 Z6920 Mounting Kit Item 4A P6920 43 Z6922 Mounting Kit Item 4B P6920 43 Smart Connected Faucet Retrofit Kit Item 5 P6900 RK W2 Description Product No Filter Kit Ite...

Page 9: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 01 20 21 C N No 143366 Prod Dwg No FV744 ...

Reviews: