background image

ZR6003AV

ZR6000AV

Sensor-Operated, Battery-Powered
Closet/Urinal Systems
ZR6000AV
ZR6000AV-WS
ZR6000AV-WS1
ZR6001AV
ZR6001AV-WS
ZR6001AV-WS1
ZR6003AV-WS
ZR6003AV-WS1

AquaSense

®

 AV

TM

ZR Series

Sensor-Operated, Battery-Powered 
Flushometer.
Installation, Operation, Maintenance 
and Parts Manual

Patented and Patents Pending

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of 

purchase. Decorative fi nishes warranted for one year. We will replace at no cost goods that prove defective provided we are notifi ed in writing 

of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and used in 

accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages whatsoever, including incidental 

or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the defective goods. Before installation and 

use, the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in 

connection therewith. Where permitted by law, the implied warranty of merchantability is expressly excluded. If the products sold hereunder are 

“consumer products,” the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement 

of the defective goods. All weights stated in our catalogs and lists are approximate and are not guaranteed.

Summary of Contents for AquaSense AV ZR Series

Page 1: ...provided we are notified in writing of such defect and the goods are returned to us prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacem...

Page 2: ...nut with a wrench Do not turn water on until batteries are inserted see 8 2 Prior to inserting the flush valve tailpiece into stop valve be certain that the o ring seal is located in o ring seal groove at the end of the tailpiece and the locking nut and locking snap ring are located as shown Care should be taken not to damage the o ring when inserting the tailpiece into the stop valve If lubricati...

Page 3: ...he final setting for urinals should be such that the fixture will not overflow when the valve is actuated twenty times in succession The stop cap screw cover should be replaced after final adjustments have been made Sensor Range Adjustment The range is factory set for urinal or closet applications If necessary the sensor range can be adjusted Pressing the reset button will initiate a ten minute se...

Page 4: ...ent For the first ten minutes of operation the red light will flash when an object is detected 2 Low Battery Indication When the batteries have reached the caution level the red light will flash when an object is detected 3 Abnormal Reflection Indicator When a reflective surface is present for longer than 30 minutes the red light will flash indicating that an object is being continuously detected ...

Page 5: ...age while reassembling the unit Insert the solenoid Item 7 into the housing and install the solenoid retaining clip Item 8 When installed properly the end of the solenoid housing is free to rotate Note Be careful not to crimp the battery wires while inserting the solenoid into the housing 3 Reinstall the RetroFlush sensor assembly Item 9 onto the flush valve using a wrench Be sure the solenoid inl...

Page 6: ...Item 8 When installed properly the end of the solenoid is free to rotate Notes Be careful not to crimp the battery wires while inserting the solenoid into the housing Also be sure the blue and gray wires of the solenoid valve extend into the sensor module cavity of the housing Item 9 6 Connect the sensor module blue and gray wires to the solenoid valve blue and gray wires and reinstall the sensor ...

Page 7: ...lume Control 3 5 GpF 3 PR6000 EU25 WS Low Consumption Urinal Volume Control 1 6 GpF 3 PR6000 EU25 WS1 Diaphragm PR6000 E15A Sensor Module Replacement Kits Product No Solenoid Valve Replacement Kit 8 9 10 PR6000 M Sensor Lens Kit 12 PR6000 SC High Volume Sensor 13 PR6000 SH Low Volume Sensor 13 PR6000 SL Battery Holder with Connecting Cable 15 16 PR6000 MB Metal Housing 11 PR6000 MH Vandal Resistan...

Page 8: ...e or chemical cleaners to clean flush valve as they will dull the luster and attack the chrome or special decorative finishes Use only mild soap and water then wipe dry with a clean cloth or towel While cleaning the bathroom tile and floor the flush valve and electronics should be protected from splattering of water cleaner acids and cleaning fluids that can damage the sensor flush valve Problem C...