PAGE 32
OCT-16
h) When finished fill oil in the pump (look changing oil)
Fill in the quantities of the SAE 20W40 oil:
AR 1064
1,0 L
When spare parts are ordered, indicate:
a) Type and serial number of the pump
b) The code of the part
c) Quantity
d) Type of delivery
When you are composing the pump, consider the screwing torques listed on the
pictures below.
Pump working faults and their repair
Fault
Cause
Control/remedy
1. Pump is not sucking
One or more valves are not
working
Checking the valve seats and
clean them
2.
The
manometer
is
oscillating
The pump is sucking air or
the air is still in the pump
Check the suction system.
Open the pressure valves on
the operating unit and leave
the pump working. Check the
pressure in the air chamber.
3. The water flow is irregular The air chamber is empty.
Raise the pressure in the
chamber for 1/10 of the
working pressure.
4. The water is flowing
without pressure
The washer on the operating
unit is defect. The valves are
not working properly.
Replace the washer or the
seat of the valve.
5. The pump is operating
loud
Oil level is too low.
Refill oil.
6. In the outgoing fluid is oil.
One or more membranes are
defect.
Replace the membranes
Summary of Contents for ZM 400 VCRA