PAGE 32
JAN-12
5. Left and right side closed, the pump is on the adjusted pressure. In this position the
powder mixer can be used and the tank mixer.
Pressure adjustment:
-
Put the handle as shown in figure 5
-
Open the pressure regulation handle (turn against the clock)
-
Put the gear in and set the working revolutions
-
Turn the pressure regulation handle (like the clock) to set the desired pressure (depends on
the nozzles)
-
Make the pressure correction with open nozzles and every time when you change the number
of the opened nozzles
25.2. PUMP AR 503
Pump:
Producer:
Annovi Reverberi S.p.A., Italy
Pump type:
AR 503 C/SP
Maximal volume flow:
55 l/min
Maximal pressure:
40 bar
Maximal rpm:
540 rpm/min
Maximal surrounding temperature:
60° C
Pump mass:
13 kg
Maximal needed power:
5,2 kW
1 2 3 4 5