14
2.
Ø2,35
Ø3,00
30
Ø2,35
Ø3,00
18
31
17
❷
❹
❸
❻
❶
❼
❺
Maintenance
2.1 Cleaning or replacement of the chuck
Page
2.1.1 Removing the chuck
❶
Open the chuck 04 and remove the
tool.
❷
Push the chuck holder 18 onto the
chuck 04.
❸
Fix the chuck 04.
❹
Turn the chuck 04 with the help of the
chuck holder 18 until the flanks of the
spindle are visible at the tip 01 and
the flat spanner 17 can be inserted.
❺
Insert the flat spanner 17 and hold it
tight.
❻
Open the chuck 04.
❼
Turn the chuck holder 18 counter-
clockwise to loosen and unscrew the
chuck 04.
Screw in the chuck
04
in the clockwise
direction up to the end stop and lightly
tighten it.
Fig . 14
Fig . 15
Fig . 16
Fig . 17
Summary of Contents for VARIOstar D50