ZXG10 iBSC Hardware Installation Guide
one end is connected with optical port ‘RX’ on SDTB/SDTB2 front panel, and the other
end is connected with ‘TX’ on peer equipment.
– End of Steps –
6.11 Installing NetNumen M31 Ethernet Cable
Context
It connects ZXG10 iBSC and background NM NetNumen M31.
shows the structure of NetNumen M31 Ethernet cable.
Figure 6-30 Structure of NetNumen M31 Ethernet cable
NetNumen M31 Ethernet cable adopts category-5 Shielded Twisted Pairs (STP).
Six NetNumen M31 Ethernet cables are needed.
Steps
1.
End A of two network cables are at OMC2 on RMPB panel of active/standby OMP rear
board respectively, and End B provides external standard RJ45 positive interface.
2.
End A of two network cables are at OMP1 on RSVB panel of active/standby SBCX rear
board respectively, and End B provides external standard RJ45 positive interface.
3.
In addition, End A of two network cables are at OMC1 on RSVB panel of active/standby
SBCX rear board respectively, and End B provides external standard RJ45 positive
interface.
The connections are shown in
6-40
SJ-20110531095035-004|2011-10-28 (R2.0)
ZTE Proprietary and Confidential
Summary of Contents for ZXG10 iBSC