Chapter 4 System Configurations and Networking Modes
4-3
OTU1
OTU2
OTU3
OTU4
OM D5-1
OM D4-5
NCP
Master CWU
Slave CWU
UPG
CH0
LINE IN
LINE OUT
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH1~CH8: optical interface of mult iplexing/ demultiplexing channel on
OMD board, CH1=1471nm, int erval=20nm
CH0: 1310nm monit or channel interface on OMD5-1, which is
connect ed to t he OSC interface of the NCP board
UP G: upgrade interface of OMD board
LINE IN/LINE OUT : optical line input / output interface of OMD board
Fig. 4.1-4 Fiber Connection of OTM Equipment (1310nm monitoring channel)
Configuration description
1. In Fig. 4.1-3, PCWAS boards are adopted to provide -48V DC power input for
the system ddl.
2. In this configuration 2-channel bidirectional OTU boards are adopted. Other
types of OTU boards can also be used as required.
3. The monitoring channel is the 1310nm channel. Therefore, the CWU shelf is
configured with an OMD5-1 board to provide an interface for the 1310nm
channel. If the monitoring channel is 1510nm. The CH3 interface of the
OMD5-1 board should be connected with the OSC interface of the NCP board.
4. If the ZXMP M600 needs to implement the multiplexing function, for a certain
wavelength, a multiplexing board (SRM42 or GEM2) can be used without OTU.