ZXMP M600 (V1.0) Technical Manual
4-2
4.1.1.2 SMU Shelf
The distribution of the slots in the SMU shelf is shown in Fig. 4.1-2. The figures here
indicate the slot numbers.
PCW
①
SRM42/GEM2
③
PCW
②
FAN
Fig. 4.1-2 Slot Distribution in the SMU Shelf
The relation between the boards and the slots is shown in Table 4.1-2.
Table 4.1-2 Relation between the Boards and Slots in the SMU Shelf
Slot No.
Boards that can be Inserted Remarks
1, 2
PCW
Each PCWAS occupies one slot.
3
SRM42, GEM2
——
4.1.2 Metro Optical Terminal Equipment (OTM)
OTM is used as a terminal node of a line to add/drop all services. Its functional
structure is shown in Fig. 1.2-2.
Take the OTM that adds/drops 8 wavelengths at the terminal for example. The board
configuration of the OTM is shown in Fig. 4.1-3, while the fiber connection is shown
in Fig. 4.1-4.
PCWAS
PCWAS
OMD5-1
NCP
OTU
OTU
PCWAS
PCWAS
OMD4-5
OTU
OTU
Master CWU shelf
Slave CWU shelf
1
2
3
4
6
5
1
2
3
4
6
5
FAN
FAN
Fig. 4.1-3 Board Configuration of OTM Equipment (which adds/drops 8 wavelengths)